| Literature DB >> 25687857 |
Mi Joo Chung1, Guk Jin Lee2, Young Jin Suh3, Hyo Chun Lee1, Sea-Won Lee1, Songmi Jeong1, Jeong Won Lee4, Sung Hwan Kim1, Dae Gyu Kang1, Jong Hoon Lee1.
Abstract
PURPOSE: This study investigated setup error and effectiveness of weekly image-guided radiotherapy (IGRT) of TomoDirect for early breast cancer.Entities:
Keywords: Breast neoplasms; Radiation; Radiotherapy setup error; TomoDirect
Mesh:
Year: 2015 PMID: 25687857 PMCID: PMC4614198 DOI: 10.4143/crt.2014.189
Source DB: PubMed Journal: Cancer Res Treat ISSN: 1598-2998 Impact factor: 4.679
Fig. 1.A breast cancer patient was estimated their bust and underbust size with a measuring tape. The breast size was assessed by subtracting underbust size from bust size; small breast, bust size: underbust size < 10 cm; large breast, bust size: underbust size ≥ 10 cm.
Fig. 2.TomoDiret planning images which deliver static beams in parallel-opposed angles.
Fig. 3.Transverse, coronal and sagittal images show the extensive setup error (> 5 mm) in a breast cancer patient with a large breast by comparing simulation and megavoltage computed tomography before radiation therapy.
Patient characteristics (n=151)
| Characteristic | Value |
|---|---|
| Age (yr) | 50 (25-83) |
| Body mass index (kg/m2) | 24 (16-33.8) |
| Site | |
| Right | 77 (51) |
| Left | 74 (49) |
| T stage | |
| pTis | 49 (32.5) |
| T1 | 87 (57.6) |
| T2 | 15 (9.9) |
| Tumor location | |
| Upper | 124 (82.1) |
| Lower | 27 (17.9) |
| Axillary staging | |
| None | 46 (30.5) |
| Sentinal node biopsy | 12 (7.9) |
| Axillary node dissection | 93 (61.6) |
| Lymph node dissected | 9 (0-31) |
| ≤ 12 | 98 (64.9) |
| > 12 | 53 (35.1) |
| Presence of seroma ≥ 15 mL | |
| No | 125 (82.8) |
| Yes | 26 (17.2) |
| Breast size | |
| Small | 117 (77.5) |
| Medium to large | 34 (22.5) |
| Adjuvant chemotherapy | |
| No | 95 (62.9) |
| Yes | 56 (37.1) |
Values are presented as median (range) or number (%).
Measurement of set-up error using megavoltage computed tomography scan
| Error | Right to left (mm) | Superior to inferior (mm) | Anterior to posterior (mm) | 3-dimensional (mm) | Angle of gantry (°) |
|---|---|---|---|---|---|
| Systemic | 1.98±0.86 | 2.02±1.01 | 2.99±1.20 | 4.67±1.28 | 0.60±0.25 |
| Random | 1.87±0.88 | 2.10±1.04 | 2.82±1.64 | 2.06±1.07 | 0.54±0.31 |
Values are presented as mean±standard deviation.
Univariate and multivariate analysis of factors affecting extensive set-up error
| Factor | No. (%) | Univariate p-value | Adjusted OR (95% Cl) | Multivariate p-value |
|---|---|---|---|---|
| Age (yr) | 0.087 | 0.675 | ||
| ≤ 50 | 78 (51.7) | 1.00 (reference) | ||
| > 50 | 73 (48.3) | 1.18 (0.54-2.50) | ||
| Body mass index (kg/m2) | 0.143 | 0.716 | ||
| ≤ 24 | 77 (51) | 1.00 (reference) | ||
| > 24 | 74 (49) | 0.86 (0.39-1.90) | ||
| Breast size | 0.022 | 0.049 | ||
| Small | 117 (77.5) | 1.00 (reference) | ||
| Medium and large | 34 (22.5) | 2.82 (1.50-7.90) | ||
| Chemotherapy | 0.083 | 0.172 | ||
| No | 95 (62.9) | 1.00 (reference) | ||
| Yes | 56 (37.1) | 1.80 (0.77-4.10) | ||
| Site | 0.078 | 0.128 | ||
| Right | 77 (51) | 1.00 (reference) | ||
| Left | 74 (49) | 1.77 (0.84-3.70) | ||
| Tumor location | 0.074 | 0.341 | ||
| Upper | 124 (82.1) | 1.00 (reference) | ||
| Lower | 27 (17.9) | 0.68 (0.31-1.40) | ||
| Node dissected | 0.051 | 0.189 | ||
| ≤ 12 | 98 (64.9) | 1.00 (reference) | ||
| > 12 | 53 (35.1) | 0.6 (0.28-1.20) | ||
| Presence of seroma ≥ 15 mL | 0.053 | 0.110 | ||
| No | 125 (82.8) | 1.00 (reference) | ||
| Yes | 26 (17.2) | 2.53 (0.80-7.90) |
OR, odds ratio; CI, confidence interval.
Fig. 4.Change of weekly absolute 3-dimensional distance of set-up error in whole breast irradiation using TomoDirect.
Variation of weekly absolute 3-dimensional distance of setup errors during breast irradiation using TomoDirect
| Setup error | Week | ||||
|---|---|---|---|---|---|
| 1 | 2 | 3 | 4 | 5 | |
| Absolute 3-dimensional error (mm) | 5.68±2.99 | 4.53±1.99 | 4.35±2.11 | 4.31±1.97 | 3.93±1.83 |
Values are presented as mean±standard deviation.