Literature DB >> 8692394

Postoperative magnetic resonance imaging with titanium implants of the thoracic and lumbar spine.

O Ortiz1, T G Pait, P McAllister, K Sauter.   

Abstract

Within recent years, the technologies of radiological imaging and spinal instrumentation have exponentially increased. New methods of preoperative imaging, that is, magnetic resonance imaging (MRI) and computed tomography, have allowed for a better understanding of surgical pathology. Such an understanding is likely to lead to a more successful surgical experience, which certainly is the case with spine surgery with instrumentation. However, after implantation of most instrumentation, imaging is greatly impaired. Metallurgic advancements in titanium were sought to reduce postoperative imaging problems. The purpose of this study is to assess the presence and extent of artifacts seen on postoperative MRI scans in patients with titanium spinal implants. Six patients, four with degenerative spine disease and two with neoplasms, had thoracic and/or lumbar spinal fixation performed with titanium instrumentation. All patients underwent postoperative conventional MRI with the use of T1-weighted, T2-weighted, and gradient-echo sequences. The scans and individual sequences were then analyzed for image quality. A progressive and significant increase in imaging artifact related to the titanium spinal instrumentation was observed on the T1-weighted, T2-weighted, and gradient-echo sequences. Titanium spinal instruments do not allow optimal postoperative imaging on conventional MRI scanners.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8692394

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  5 in total

1.  The interobserver-validated relevance of intervertebral spacer materials in MRI artifacting.

Authors:  T Ernstberger; G Heidrich; T Bruening; S Krefft; G Buchhorn; H M Klinger
Journal:  Eur Spine J       Date:  2006-02-07       Impact factor: 3.134

2.  Implant detectibility of intervertebral disc spacers in post fusion MRI: evaluation of the MRI scan quality by using a scoring system--an in vitro study.

Authors:  Thorsten Ernstberger; Gabert Heidrich; Wolfgang Schultz; Eckhardt Grabbe
Journal:  Neuroradiology       Date:  2006-11-04       Impact factor: 2.804

3.  The role of CT myelography in sparing the spinal cord during definitive radiotherapy in vertebral hemangioma.

Authors:  S P Sudha; M S Gopalakrishnan; K Saravanan
Journal:  J Appl Clin Med Phys       Date:  2017-08-18       Impact factor: 2.102

4.  Artifacts in spine magnetic resonance imaging due to different intervertebral test spacers: an in vitro evaluation of magnesium versus titanium and carbon-fiber-reinforced polymers as biomaterials.

Authors:  Thorsten Ernstberger; Gottfried Buchhorn; Gabert Heidrich
Journal:  Neuroradiology       Date:  2009-05-26       Impact factor: 2.804

5.  Magnetic resonance imaging evaluation of intervertebral test spacers: an experimental comparison of magnesium versus titanium and carbon fiber reinforced polymers as biomaterials.

Authors:  T Ernstberger; G Buchhorn; G Heidrich
Journal:  Ir J Med Sci       Date:  2009-08-20       Impact factor: 1.568

  5 in total