Liver masses: replacement of conventional T2-weighted spin-echo MR imaging with breath-hold MR imaging.

J Gaa1, H Hatabu, R L Jenkins, J P Finn, R R Edelman.   

Abstract

PURPOSE: To evaluate breath-hold magnetic resonance (MR) imaging with single-shot and multishot T2-weighted fast spin-echo (SE) and inversion-recovery (IR) SE echo-planar (EP) SE (IR-SE-EP) sequences compared with conventional T2-weighted SE imaging for detection of liver masses.
MATERIALS AND METHODS: Imaging with all sequences was performed in 32 patients on a 1.5-T whole-body system. Images were compared on the basis of lesion-to-liver contrast-to-noise ratio (C/N), lesion conspicuity, and image quality. Image analysis was performed by two experienced radiologists in consensus.
RESULTS: Lesion-to-liver C/Ns were highest on fat-suppressed-half-Fourier-single-shot-fast-SE images. For solid lesions, the lesion-to-liver C/Ns were highest with IR-fast-SE, which was significantly better (P < .05) than IR-SE-EP and conventional SE techniques and also produced the best image quality. Sensitivity with IR-fast-SE was 96%; with fat-suppressed-half-Fourier-single-shot-fast-SE, 92%; with fat-suppressed-fast-SE, 89%; with IR-SE-EP, 83%; and with conventional SE, 78%.
CONCLUSION: T2-weighted breath-hold imaging, particularly IR-fast-SE imaging, was more sensitive for hepatic masses than conventional SE imaging, with a substantial reduction in acquisition time. Half-Fourier-single-shot-fast-SE imaging was especially useful in patients who were unable to hold their breath.

Entities:  

Mesh:

Year:  1996        PMID: 8685342     DOI: 10.1148/radiology.200.2.8685342

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  10 in total

Review 1.  [(1)H magnetic resonance spectroscopy (MRS) of the liver and hepatic malignant tumors at 3.0 Tesla].

Authors:  F Fischbach; M Thormann; J Ricke
Journal:  Radiologe       Date:  2004-12       Impact factor: 0.635

2.  T2-weighted breathold imaging of the liver: a quantitative and qualitative comparison of fast spin echo and half Fourier single shot fast spin echo imaging.

Authors:  T K Helmberger; J Schröder; N Holzknecht; M Gregor; A Heuck; R Petsch; M F Reiser
Journal:  MAGMA       Date:  1999-10       Impact factor: 2.310

Review 3.  [Modern imaging for liver metastases from colorectal tumors].

Authors:  J Gaa; H Wieder; M Schwaiger; E J Rummeny
Journal:  Chirurg       Date:  2005-06       Impact factor: 0.955

Review 4.  Lesion discrimination with breath-hold hepatic diffusion-weighted imaging: a meta-analysis.

Authors:  Zhi-Guang Chen; Li Xu; Si-Wei Zhang; Yan Huang; Rui-Huan Pan
Journal:  World J Gastroenterol       Date:  2015-02-07       Impact factor: 5.742

5.  Comparison of diffusion-weighted imaging and T2-weighted single shot fast spin-echo: Implications for LI-RADS characterization of hepatocellular carcinoma.

Authors:  Robert M Hicks; Judy Yee; Michael A Ohliger; Stefanie Weinstein; Jeffrey Kao; Nabia S Ikram; Thomas A Hope
Journal:  Magn Reson Imaging       Date:  2016-04-21       Impact factor: 2.546

6.  Preliminary experience with a new double-echo half-Fourier single-shot turbo spin echo acquisition in the characterization of liver lesions.

Authors:  H Bosmans; S Gryspeerdt; L Van Hoe; S Van Oostende; T De Jaegere; B Kiefer; A L Baert; G Marchal
Journal:  MAGMA       Date:  1997-03       Impact factor: 2.310

7.  Selection of patients for resection of colorectal metastases to the liver using diagnostic laparoscopy and laparoscopic ultrasonography.

Authors:  F D Rahusen; M A Cuesta; P J Borgstein; R P Bleichrodt; F Barkhof; T Doesburg; S Meijer
Journal:  Ann Surg       Date:  1999-07       Impact factor: 12.969

8.  Quantitative proton magnetic resonance spectroscopy of the normal liver and malignant hepatic lesions at 3.0 Tesla.

Authors:  F Fischbach; T Schirmer; M Thormann; T Freund; J Ricke; H Bruhn
Journal:  Eur Radiol       Date:  2008-05-20       Impact factor: 5.315

9.  Synchronisation strategies in T2-weighted MR imaging for detection of liver lesions: Application on a nude mouse model.

Authors:  L Baboi; L Milot; C Lartizien; C Roche; J-Y Scoazec; F Pilleul; O Beuf
Journal:  Biomed Imaging Interv J       Date:  2007-10-01

Review 10.  New MR techniques for the detection of liver metastases.

Authors:  J Ward
Journal:  Cancer Imaging       Date:  2006-05-31       Impact factor: 3.909

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.