Zhi-Guang Chen1, Li Xu1, Si-Wei Zhang1, Yan Huang1, Rui-Huan Pan1. 1. Zhi-Guang Chen, Li Xu, Si-Wei Zhang, Department of Radiology, Guangdong Provincial Traditional Chinese Medicine Hospital, Guangzhou 510120, Guangdong Province, China.
Abstract
AIM: To investigate the diagnostic capability of breath-hold diffusion-weighted imaging (DWI) for differentiation between malignant and benign hepatic lesions. METHODS: A total of 614 malignant liver lesions (132 hepatocellular carcinomas, 468 metastases and 14 intrahepatic cholangiocarcinomas) and 291 benign liver lesions (102 hemangiomas, 158 cysts, 24 focal nodular hyperplasia, 1 angiomyolipoma and 6 hepatic adenomas) were included from seven studies (eight sets of data). RESULTS: The pooled sensitivity and specificity of breath-hold DWI were 0.93 [95% confidence interval (CI): 0.91-0.95] and 0.87 (95%CI: 0.83-0.91), respectively. The positive likelihood ratio and negative likelihood ratio were 7.28 (95%CI: 4.51-11.76) and 0.09 (95%CI: 0.05-0.17), respectively. The P value for χ (2) heterogeneity for all pooled estimates was < 0.05. From the fitted summary receiver operating characteristic curve, the area under the curve and Q* index were 0.96 and 0.91, respectively. Publication bias was not present (t = 0.49, P = 0.64). The meta-regression analysis indicated that evaluated covariates including magnetic resonance imaging modality, echo time, mean age, maximum b factor, and number of b factors were not sources of heterogeneity (all P > 0.05). CONCLUSION: Breath-hold DWI is useful for differentiating between malignant and benign hepatic lesions. The diffusion characteristics of benign lesions that mimic malignant ones have rarely been investigated.
AIM: To investigate the diagnostic capability of breath-hold diffusion-weighted imaging (DWI) for differentiation between malignant and benign hepatic lesions. METHODS: A total of 614 malignant liver lesions (132 hepatocellular carcinomas, 468 metastases and 14 intrahepatic cholangiocarcinomas) and 291 benign liver lesions (102 hemangiomas, 158 cysts, 24 focal nodular hyperplasia, 1 angiomyolipoma and 6 hepatic adenomas) were included from seven studies (eight sets of data). RESULTS: The pooled sensitivity and specificity of breath-hold DWI were 0.93 [95% confidence interval (CI): 0.91-0.95] and 0.87 (95%CI: 0.83-0.91), respectively. The positive likelihood ratio and negative likelihood ratio were 7.28 (95%CI: 4.51-11.76) and 0.09 (95%CI: 0.05-0.17), respectively. The P value for χ (2) heterogeneity for all pooled estimates was < 0.05. From the fitted summary receiver operating characteristic curve, the area under the curve and Q* index were 0.96 and 0.91, respectively. Publication bias was not present (t = 0.49, P = 0.64). The meta-regression analysis indicated that evaluated covariates including magnetic resonance imaging modality, echo time, mean age, maximum b factor, and number of b factors were not sources of heterogeneity (all P > 0.05). CONCLUSION: Breath-hold DWI is useful for differentiating between malignant and benign hepatic lesions. The diffusion characteristics of benign lesions that mimic malignant ones have rarely been investigated.
Authors: D Löwenthal; M Zeile; W Y Lim; C Wybranski; F Fischbach; G Wieners; M Pech; S Kropf; J Ricke; O Dudeck Journal: Eur Radiol Date: 2010-10-02 Impact factor: 5.315
Authors: N M Rofsky; V S Lee; G Laub; M A Pollack; G A Krinsky; D Thomasson; M M Ambrosino; J C Weinreb Journal: Radiology Date: 1999-09 Impact factor: 11.105