Literature DB >> 8662105

Parathyroid scintigraphy: comparison of technetium-99m methoxyisobutylisonitrile and technetium-99m tetrofosmin studies.

R M Aigner1, G F Fueger, R Nicoletti.   

Abstract

We report the preliminary results of a prospective study demonstrating tetrofosmin uptake in surgically and histologically proven parathyroid adenomas. In ten patients with primary chronic hyperparathyroidism, parathyroid imaging was performed using (1) technetium-99m methoxyisobutylisonitrile (MIBI) and (2) 99mTc-1, 2-bis(bis(2-ethoxyethyl)phosphino)ethane (tetrofosmin) within a time interval of 3-5 days. Both tracers correctly identified the parathyroid adenomas by focal prolonged tracer retention. On visual inspection image contrast was generally higher with MIBI than with tetrofosmin in all the patients studied. Tetrofosmin showed a slower elimination from the parathyroid adenomas than MIBI in six of the ten cases. Our preliminary results show that tetrofosmin, like MIBI, as a feasible, sensitive tracer for parathyroid scintigraphy. For routine use, the rapid kit preparation without heating and the lower radiation dose to the patient make tetrofosmin an alternative tracer for parathyroid scintigraphy. Further evaluation is needed to determine which of the two tracers is the more sensitive for the detection of parathyroid adenomas, and which tracer properties better reflect the degree of endocrine activity.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8662105     DOI: 10.1007/bf00834533

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  9 in total

1.  Failure of perchlorate to inhibit Tc-99m isonitrile binding by the thyroid during myocardial perfusion studies.

Authors:  A C Civelek; K Durski; I Shafique; K Matsumura; S Sostre; H N Wagner; P W Ladenson
Journal:  Clin Nucl Med       Date:  1991-05       Impact factor: 7.794

2.  Ultrastructural histology correlates with results of thallium-201/technetium-99m parathyroid subtraction scintigraphy.

Authors:  D Sandrock; M J Merino; J A Norton; R D Neumann
Journal:  J Nucl Med       Date:  1993-01       Impact factor: 10.057

3.  Functional imaging of multidrug-resistant P-glycoprotein with an organotechnetium complex.

Authors:  D Piwnica-Worms; M L Chiu; M Budding; J F Kronauge; R A Kramer; J M Croop
Journal:  Cancer Res       Date:  1993-03-01       Impact factor: 12.701

4.  Parathyroid imaging with technetium-99m-sestamibi: preoperative localization and tissue uptake studies.

Authors:  M J O'Doherty; A G Kettle; P Wells; R E Collins; A J Coakley
Journal:  J Nucl Med       Date:  1992-03       Impact factor: 10.057

5.  Detection and localization of parathyroid adenomas in patients with hyperparathyroidism using a single radionuclide imaging procedure with technetium-99m-sestamibi (double-phase study)

Authors:  R Taillefer; Y Boucher; C Potvin; R Lambert
Journal:  J Nucl Med       Date:  1992-10       Impact factor: 10.057

6.  Visualization of a parathyroid adenoma with Tc-99m MIBI in a case with iodine saturation and impaired thallium uptake.

Authors:  K Osmanagaoglu; K Schelstraete; M Lippens; E Obrie; I De Feyter
Journal:  Clin Nucl Med       Date:  1993-03       Impact factor: 7.794

7.  Technetium-99m-1,2-bis[bis(2-ethoxyethyl) phosphino]ethane: human biodistribution, dosimetry and safety of a new myocardial perfusion imaging agent.

Authors:  B Higley; F W Smith; T Smith; H G Gemmell; P Das Gupta; D V Gvozdanovic; D Graham; D Hinge; J Davidson; A Lahiri
Journal:  J Nucl Med       Date:  1993-01       Impact factor: 10.057

8.  Technetium-99m-tetrofosmin as a new radiopharmaceutical for myocardial perfusion imaging.

Authors:  J D Kelly; A M Forster; B Higley; C M Archer; F S Booker; L R Canning; K W Chiu; B Edwards; H K Gill; M McPartlin
Journal:  J Nucl Med       Date:  1993-02       Impact factor: 10.057

9.  Technetium-99m hexakis 2-methoxyisobutyl isonitrile: human biodistribution, dosimetry, safety, and preliminary comparison to thallium-201 for myocardial perfusion imaging.

Authors:  F J Wackers; D S Berman; J Maddahi; D D Watson; G A Beller; H W Strauss; C A Boucher; M Picard; B L Holman; R Fridrich
Journal:  J Nucl Med       Date:  1989-03       Impact factor: 10.057

  9 in total
  4 in total

Review 1.  Parathyroid nuclear scan. A focused review on the technical and biological factors affecting its outcome.

Authors:  Subramanian Kannan; Mira Milas; Donald Neumann; Rikesh T Parikh; Alan Siperstein; Angelo Licata
Journal:  Clin Cases Miner Bone Metab       Date:  2014-01

2.  18F-Fluorocholine PET/CT in the assessment of primary hyperparathyroidism compared with 99mTc-MIBI or 99mTc-tetrofosmin SPECT/CT: a prospective dual-centre study in 100 patients.

Authors:  Mohsen Beheshti; Lukas Hehenwarter; Zeinab Paymani; Gundula Rendl; Larisa Imamovic; Rupert Rettenbacher; Oleksiy Tsybrovskyy; Werner Langsteger; Christian Pirich
Journal:  Eur J Nucl Med Mol Imaging       Date:  2018-03-08       Impact factor: 9.236

3.  2009 EANM parathyroid guidelines.

Authors:  Elif Hindié; Omer Ugur; David Fuster; Michael O'Doherty; Gaia Grassetto; Pablo Ureña; Andrew Kettle; Seza A Gulec; Francesca Pons; Domenico Rubello
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-07       Impact factor: 9.236

4.  Parathyroid adenoma detected with 99mTc-tetrofosmin dual-phase scintigraphy: a case report.

Authors:  Konstantinos Romanidis; Evangelos Karathanos; Eleni-Aikaterini Nagorni; Alexandra Giatromanolaki; Efthimios Sibridis; Athanassios Zissimopoulos; Theodosia Vogiatzaki; Constantinos Simopoulos; Michael Pitiakoudis
Journal:  BMC Res Notes       Date:  2014-06-04
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.