Literature DB >> 8418268

Technetium-99m-1,2-bis[bis(2-ethoxyethyl) phosphino]ethane: human biodistribution, dosimetry and safety of a new myocardial perfusion imaging agent.

B Higley1, F W Smith, T Smith, H G Gemmell, P Das Gupta, D V Gvozdanovic, D Graham, D Hinge, J Davidson, A Lahiri.   

Abstract

A novel 99mTc complex (1,2-bis[bis(2-ethoxyethyl)phosphino] ethane, 99mTc-tetrofosmin) has been developed to replace 201Tl in myocardial perfusion imaging. Biodistribution, safety and dosimetry of 99mTc-tetrofosmin were studied in 12 male volunteers, each at rest and during exercise. Safety parameters measured to 48 hr postinjection revealed no clinically significant long-term drug-related changes. Biodistribution was studied by acquiring whole-body or serial static images up to 48 hr postinjection. Technetium-99m-tetrofosmin shows good heart uptake (1.2%) with retention. Clearance is excellent from blood (< 5% by 10 min), liver (< 4.5% by 60 min) and lung. Sequestration of activity by skeletal muscle is enhanced during exercise. Radiation dosimetry calculations indicate that the effective dose, assuming a 3.5 hr bladder voiding period, is 32.9 x 10(-3) rad/mCi (8.9 x 10(-3) mSv/MBq) at rest and 26.7 x 10(-3) rad/mCi (7.1 x 10(-3) mSv/MBq) after exercise. Technetium-99m-tetrofosmin can produce high quality myocardial images from 5 min to several hours postinjection.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8418268

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  83 in total

1.  Clinical implication of down-scatter in attenuation-corrected myocardial SPECT.

Authors:  H Almquist; H Arheden; A H Arvidsson; O Pahlm; J Palmer
Journal:  J Nucl Cardiol       Date:  1999 Jul-Aug       Impact factor: 5.952

Review 2.  An overview of radiotracers in nuclear cardiology.

Authors:  W Acampa; C Di Benedetto; A Cuocolo
Journal:  J Nucl Cardiol       Date:  2000 Nov-Dec       Impact factor: 5.952

3.  Evaluation of left ventricular wall motion, volumes, and ejection fraction by gated myocardial tomography with technetium 99m-labeled tetrofosmin: a comparison with cine magnetic resonance imaging.

Authors:  P Vaduganathan; Z X He; G W Vick; J J Mahmarian; M S Verani
Journal:  J Nucl Cardiol       Date:  1999 Jan-Feb       Impact factor: 5.952

Review 4.  Comparison of Tl-201 with Tc-99m-labeled myocardial perfusion agents: technical, physiologic, and clinical issues.

Authors:  P Kailasnath; A J Sinusas
Journal:  J Nucl Cardiol       Date:  2001 Jul-Aug       Impact factor: 5.952

5.  Improved diagnostic accuracy of planar imaging with technetium 99m-labeled tetrofosmin compared with thallium-201 for the detection of coronary artery disease.

Authors:  R S Khattar; R C Hendel; J C Crawley; F J Wackers; P Rigo; B L Zaret; B S Sridhara; A Lahiri
Journal:  J Nucl Cardiol       Date:  1997 Jul-Aug       Impact factor: 5.952

6.  Myocardial ischemia in Kawasaki disease: evaluation with dipyridamole stress technetium 99m tetrofosmin scintigraphy.

Authors:  Tsuyoshi Fukuda; Masatoshi Ishibashi; Tatsuo Yokoyama; Masaki Otaki; Tohru Shinohara; Yoshihide Nakamura; Toshiharu Miyake; Takashi Kudoh; Hidetaka Oku
Journal:  J Nucl Cardiol       Date:  2002 Nov-Dec       Impact factor: 5.952

7.  Breast scintigraphy: procedure guidelines for tumour imaging.

Authors:  Emilio Bombardieri; Cumali Aktolun; Richard P Baum; Angelika Bishof-Delaloye; John Buscombe; Jean François Chatal; Lorenzo Maffioli; Roy Moncayo; Luc Mortelmans; Sven N Reske
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-12       Impact factor: 9.236

8.  Novel SPECT perfusion imaging agents with improved myocardial or liver kinetics: experimental studies and the need for clinical evaluation.

Authors:  Laurent M Riou; Alexis Broisat
Journal:  J Nucl Cardiol       Date:  2010-10       Impact factor: 5.952

9.  Assessment of area at risk and efficacy of treatment in patients with acute coronary syndrome using 99mTc tetrofosmin imaging in humans.

Authors:  H Matsuo; S Watanabe; Y Nishida; T Matsubara; M Kano; A Sugiyama; Y Matsuno; H Oda; Y Kotoo; H Oohashi
Journal:  Ann Nucl Med       Date:  1993-11       Impact factor: 2.668

10.  Technetium-99m tetrofosmin uptake in lung cancer: comparison with thallium-201.

Authors:  I Matsunari; S Kinuya; T Nishikawa; M Matoba; K Murakita; M Ohguchi; K Ichiyanagi; J Taki; N Tonami; K Hisada
Journal:  Ann Nucl Med       Date:  1996-02       Impact factor: 2.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.