Literature DB >> 1531500

Parathyroid imaging with technetium-99m-sestamibi: preoperative localization and tissue uptake studies.

M J O'Doherty1, A G Kettle, P Wells, R E Collins, A J Coakley.   

Abstract

The accepted radionuclide method for imaging abnormal parathyroid tissue has been the combined use of [99mTc]pertechnetate 201Tl-chloride. Various problems with this approach, however, have suggested the need for an improved parathyroid imaging agent. This study examined the use of 99mTc-sestamibi as a parathyroid imaging agent compared with 201Tl-chloride. Fifty-seven patients were scanned with both 99mTc-sestamibi and 201Tl preoperatively. There were 40 adenomas, of which 37 were localized with 201Tl and 39 with sestamibi. Fifteen patients had hyperplastic glands, of which 29 glands were localized with 201Tl and 32 with sestamibi. Possible differences in uptake of the two agents by thyroid and parathyroid tissue were examined by administering 10 MBq of each agent to patients undergoing surgical exploration and biopsy. Preoperatively 20 patients were studied (13 adenomas and 7 with hyperplasia). Thallium-201 uptake was higher in both the parathyroid and thyroid tissue than sestamibi. However, the uptake per gram of parathyroid tissue of sestamibi was higher than the uptake per gram of thyroid tissue. This was not true for 201Tl. Technetium-99m-sestamibi was at least as effective as 201Tl in parathyroid localization. This may be partly due to a higher target-to-background ratio, but also to the superior physical characteristics of 99mTc.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1531500

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  46 in total

1.  Diagnostic efficiency of sestamibi gammagraphy and Doppler sonography in the preoperative assessment of breast lesions.

Authors:  Antonio Piñero; Pedro José Galindo; Julián Illana; Francisco Nicolás; Manuel Reus; María Dolores Hernández; Isidro Durán; Manuel Canteras; Pascual Parrilla
Journal:  Clin Transl Oncol       Date:  2006-02       Impact factor: 3.405

2.  How should the "optimal" pre-operative localizing imaging work-up in hyperparathyroid patients be?

Authors:  D Rubello
Journal:  J Endocrinol Invest       Date:  2006-10       Impact factor: 4.256

Review 3.  Imaging for primary hyperparathyroidism--an evidence-based analysis.

Authors:  Radu Mihai; Dietmar Simon; Per Hellman
Journal:  Langenbecks Arch Surg       Date:  2009-07-10       Impact factor: 3.445

4.  99mTc-MIBI accumulation in the parathyroid autograft in a patient with recurrent hyperparathyroidism.

Authors:  H Ohta; T Komibuchi; M Nishimura; K Nishimura; Y Nagao; H Watanabe; S Fujikawa; S Nakaishi; S Oki
Journal:  Ann Nucl Med       Date:  1996-05       Impact factor: 2.668

Review 5.  SPECT/CT: an update on technological developments and clinical applications.

Authors:  Michael Ljungberg; P Hendrik Pretorius
Journal:  Br J Radiol       Date:  2017-01-16       Impact factor: 3.039

6.  Negative imaging studies for primary hyperparathyroidism are unavoidable: correlation of sestamibi and high-resolution ultrasound scanning with histological analysis in 150 patients.

Authors:  Radu Mihai; Fergus Gleeson; Ian D Buley; Derek E Roskell; Gregory P Sadler
Journal:  World J Surg       Date:  2006-05       Impact factor: 3.352

7.  Label-free intraoperative parathyroid localization with near-infrared autofluorescence imaging.

Authors:  Melanie A McWade; Constantine Paras; Lisa M White; John E Phay; Carmen C Solórzano; James T Broome; Anita Mahadevan-Jansen
Journal:  J Clin Endocrinol Metab       Date:  2014-12       Impact factor: 5.958

8.  Thymic carcinoid and parathyroid hyperplasia detection with 99mTc-MIBI men type 1.

Authors:  C Marí; J León; J Farrerons; X Matis-Guiu; A Tembl; J C Martin; A Flotats; L l Bernà
Journal:  J Endocrinol Invest       Date:  1999-11       Impact factor: 4.256

9.  Preoperative imaging of abnormal parathyroid glands in patients with hyperparathyroid disease using combination Tc-99m-pertechnetate and Tc-99m-sestamibi radionuclide scans.

Authors:  J P Wei; G J Burke; A R Mansberger
Journal:  Ann Surg       Date:  1994-05       Impact factor: 12.969

10.  Sestamibi scanning and minimally invasive radioguided parathyroidectomy without intraoperative parathyroid hormone measurement.

Authors:  Richard E Goldstein; Dean Billheimer; William H Martin; Ken Richards
Journal:  Ann Surg       Date:  2003-05       Impact factor: 12.969

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.