Computed radiography in neonatal and pediatric intensive care units: a comparison of 2.5 K x 2 K soft-copy images vs digital hard-copy film.

P W Brill1, P Winchester, P Cahill, M Lesser, S M Durfee, C S Giess, P A Auld, B Greenwald.   

Abstract

OBJECTIVE: The goal of the study was to determine whether soft-copy images on high-resolution monitors (2.5 K x 2 K) are suitable for primary interpretation of images from pediatric and neonatal intensive care units. The hypotheses were that hard and soft images yield similar diagnostic information, and that both residents and faculty radiologists can use monitors effectively. Previous reports have produced conflicting results; the need for larger sample sizes has been emphasized.
MATERIALS AND METHODS: One thousand one hundred and four images produced by computed radiography using the Kodak Ectascan Imagelink system were prospectively analyzed by two pediatric radiologists, one reading hard copy and the other soft copy of the same images. Bias was controlled by equal distribution of modalities between observers and by daily alternation of modality. Hard- and soft-copy observations of presence or absence of nine specific tubes and nine specific diagnostic findings were compared. Interobserver differences between pediatric radiologists and radiology residents were studied on additional images. The kappa statistic was used to evaluate the level of agreement for all observations.
RESULTS: There was excellent agreement between hard and soft copy interpretation for each tube and diagnostic finding (kappa values 0.93-1.0) and excellent interobserver agreement between two pediatric radiologists (kappa values 0.84-1.0). The level of agreement between radiology residents and pediatric radiologist was excellent for the most objective findings. All results were statistically significant (p < 0.001).
CONCLUSION: High resolution soft-copy images are suitable for primary interpretation in patients in pediatric and neonatal intensive care units.

Entities:  

Mesh:

Year:  1996        PMID: 8657462     DOI: 10.1007/bf01395709

Source DB:  PubMed          Journal:  Pediatr Radiol        ISSN: 0301-0449


  9 in total

1.  Issues in the use of kappa.

Authors:  M Ker
Journal:  Invest Radiol       Date:  1991-01       Impact factor: 6.016

2.  Detection of pneumothorax: comparison of digital and conventional chest imaging.

Authors:  L L Fajardo; B J Hillman; G D Pond; R F Carmody; J E Johnson; W R Ferrell
Journal:  AJR Am J Roentgenol       Date:  1989-03       Impact factor: 3.959

3.  Receiver-operating-characteristic study of chest radiographs in children: digital hard-copy film vs 2K x 2K soft-copy images.

Authors:  M Razavi; J W Sayre; R K Taira; M Simons; H K Huang; K S Chuang; G Rahbar; H Kangarloo
Journal:  AJR Am J Roentgenol       Date:  1992-02       Impact factor: 3.959

4.  Digital imaging with a photostimulable phosphor in the chest of newborns.

Authors:  M D Cohen; B P Katz; L A Kalasinski; S J White; J A Smith; B Long
Journal:  Radiology       Date:  1991-12       Impact factor: 11.105

5.  Accuracy of digital radiography using stimulable phosphor for diagnosis of pneumothorax.

Authors:  M Kehler; U Albrechtsson; A Andrésdóttir; H Lárusdóttir; A Lundin
Journal:  Acta Radiol       Date:  1990-01       Impact factor: 1.990

6.  High-resolution computer display of portable, digital, chest radiographs of adults: suitability for primary interpretation.

Authors:  M S Frank; R G Jost; P L Molina; D J Anderson; S L Solomon; R A Whitman; S M Moore
Journal:  AJR Am J Roentgenol       Date:  1993-03       Impact factor: 3.959

7.  Volume detection threshold: quantitative comparison of computed radiography and screen-film radiography in detection of pneumothoraces in an animal model that simulates the neonate.

Authors:  S Don; M D Cohen; R A Kruger; T A Winkler; B P Katz; W Li; R G Dreesen; N Kennan; R Tarver; E C Klatte
Journal:  Radiology       Date:  1995-03       Impact factor: 11.105

8.  Digital radiography and conventional imaging of the chest: a comparison of observer performance.

Authors:  F L Thaete; C R Fuhrman; J H Oliver; C A Britton; W L Campbell; J H Feist; W H Straub; P L Davis; M B Plunkett
Journal:  AJR Am J Roentgenol       Date:  1994-03       Impact factor: 3.959

9.  Comparison of hard- and soft-copy digital chest images with different matrix sizes for managing coronary care unit patients.

Authors:  R J Steckel; P Batra; S Johnson; J Sayre; K Brown; K Haker; D Young; M Zucker
Journal:  AJR Am J Roentgenol       Date:  1995-04       Impact factor: 3.959

  9 in total
  2 in total

1.  Comparison of liquid crystal versus cathode ray tube display for the detection of simulated chest lesions.

Authors:  Elisabeth Oschatz; Mathias Prokop; Martina Scharitzer; Michael Weber; Csilla Balassy; Cornelia Schaefer-Prokop
Journal:  Eur Radiol       Date:  2004-09-08       Impact factor: 5.315

Review 2.  Advances in radiology.

Authors:  T R Goodman; K McHugh
Journal:  Arch Dis Child       Date:  1997-09       Impact factor: 3.791

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.