Comparison of hard- and soft-copy digital chest images with different matrix sizes for managing coronary care unit patients.

R J Steckel1, P Batra, S Johnson, J Sayre, K Brown, K Haker, D Young, M Zucker.   

Abstract

OBJECTIVE: This study was to determine whether different digital display formats for portable chest radiographs of coronary care unit patients would provide comparable information for clinical care. In particular, we tried to ascertain whether 1024 x 1024 pixel (1K) images on a picture archiving and communication system (PACS) workstation would be comparable to 1760 x 2140 pixel (2K) images on workstations or to digital films. If comparability could be proved, we hypothesized that 1K workstations could considerably lower equipment and film costs and facilitate image transmission from point to point.
MATERIALS AND METHODS: Four chest radiologists read a panel of chest studies assembled from 98 coronary care unit patients, comparing 1K and 2K soft-copy images with digital hard copies. For all three image types for the 98 patients, the readers evaluated nine image parameters that the cardiologists deemed essential for clinical decision making. Two other chest radiologists reviewed each patient's three image types, historical chest images, current and prior radiologic reports, and medical record to determine the consensus, or "truth findings."
RESULTS: With one exception (small pleural effusions), the receiver operating characteristic analysis showed no significant differences in the clinical information derived from the three image types.
CONCLUSION: For clinical management in a coronary care unit, comparable information can be obtained from digital radiologic chest studies using a 1K x 1K soft-copy format, a 2K x 2K soft-copy format, or a hard copy (film). Substantial savings in cost and time are therefore possible by using soft-copy images and lower resolution (1K x 1K) workstations and, when necessary, by transmitting images on regular telephone lines.

Entities:  

Mesh:

Year:  1995        PMID: 7726034     DOI: 10.2214/ajr.164.4.7726034

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  4 in total

1.  A comparison between digital images viewed on a picture archiving and communication system diagnostic workstation and on a PC-based remote viewing system by emergency physicians.

Authors:  A Parasyn; R M Hanson; J K Peat; M De Silva
Journal:  J Digit Imaging       Date:  1998-02       Impact factor: 4.056

2.  Computed radiography in neonatal and pediatric intensive care units: a comparison of 2.5 K x 2 K soft-copy images vs digital hard-copy film.

Authors:  P W Brill; P Winchester; P Cahill; M Lesser; S M Durfee; C S Giess; P A Auld; B Greenwald
Journal:  Pediatr Radiol       Date:  1996

3.  Electronic imaging impact on image and report turnaround times.

Authors:  C W Mattern; B F King; N J Hangiandreou; A Swenson; L L Jorgenson; W E Webbles; T W Okrzynski; B J Erickson; B Williamson; G S Forbes
Journal:  J Digit Imaging       Date:  1999-05       Impact factor: 4.056

4.  Impact of electronic imaging on clinician behavior in the urgent care setting.

Authors:  C W Mattern; B J Erickson; B F King; T W Okryznski
Journal:  J Digit Imaging       Date:  1999-05       Impact factor: 4.056

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.