| Literature DB >> 32436163 |
Reymus Marcel1, Hickel Reinhard2, Keßler Andreas2.
Abstract
OBJECTIVES: The aim of this study was to investigate the accuracy of CAD/CAM-fabricated bite splints in dependence of fabrication method (milling vs 3D printing), positioning (horizontal vs vertical), selection of material, and method of deviation measurement.Entities:
Keywords: Accuracy; Bite splints; CNC milling; Precision; Three-dimensional printing; Trueness
Mesh:
Year: 2020 PMID: 32436163 PMCID: PMC7666673 DOI: 10.1007/s00784-020-03329-x
Source DB: PubMed Journal: Clin Oral Investig ISSN: 1432-6981 Impact factor: 3.573
Fig. 1Study design
Fig. 2Intaglio surface of the CAD-file
Investigated materials, manufactures, machines of manufacturing, and post-curing methods
| Material | Manufacturer | Machine | Layer thickness* | Post-curing |
|---|---|---|---|---|
| Dental LT | Formlabs (Sommerville, Massachusetts, US) | Form 2 (Formlabs) [AM] | 100 μm | LC-3DPrint Box (NextDent) for 10 min |
| Ortho Clear | NextDent (Soesterberg, Netherlands) | D20 II (Rapidshape, Heimsheim, Germany) [AM] | 50 μm | LC-3DPrint Box (NextDent) for 10 min |
| Freeprint Splint | Detax (Ettlingen, Germany) | D20 II (Rapidshape, Heimsheim, Germany) [AM] | 100 μm | Otoflash G171 (NK Optik, Baierbrunn, Germany) for 2000 flashes |
| V-Splint | VOCO (Cuxhaven, Germany) | SolFlex 350 (VOCO) [AM] | 50 μm | Otoflash G171 (NK Optik, Baierbrunn, Germany) for 2000 flashes |
| ProArt CAD Splint | Ivoclar-Vivadent (Schaan, Liechtenstein) | MC X5 (Dentsply-Sirona, Bensheim, Germany) [subtractive] | Not applicable | Not applicable |
*By default, as specified by the manufactures
Root mean square of deviations from reference file (trueness) by additively manufactured bite splints in either horizontal or vertical building positions and one milled material (mean ± SD; min/median/max)
| Measurement | Material | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Dental LT | Ortho Clear | Freeprint Splint | V-Splint | ProArt CAD Splint | |||||
| Position | |||||||||
| Horizontal | Vertical | Horizontal | Vertical | Horizontal | Vertical | Horizontal | Vertical | ||
| Cloud1 | 101.2 ± 4.13; 93.8/101.3/106.9a | 135.49 ± 7.10; 124.0/137.1/143.5b | 93.32 ± 1.32; 90.2/93.5/94.9 | 99.82 ± 1.51; 97.6/100.0/101.6a | 122.66 ± 4.67; 114.4/122.6/133.3 | 137.31 ± 4.65; 129.7/136.6/144.6b | 98.92 ± 2.27.95.2/99.2/103.4a | 108.84 ± 1.92; 106.2/108.5/112.5 | 67.69 ± 2.16; 65.0/67.3/71.6 |
| Cloud2 | 77.39 ± 5.28; 68.9/77.3/84.9a,A | 118.67 ± 8.00; 105.5/120.8/127.6b | 69.43 ± 1.61; 65.5/70.0/71.1A | 78.68 ± 2.65; 74.8/79.0/83.2a | 104.25 ± 5.53; 95.9/104.3/116.8A | 118.42 ± 4.18; 110.8/117.8/125.3b | 76.05 ± 3.01; 71.0/76.4/81.8a,A | 86.97 ± 2.39; 84.1/86.6/92.1A | 35.08 ± 3.46; 30.0/35.0/41.1A |
| GOM | 76.61 ± 4.46; 70.9/76.3/84.5a,A | 126.82 ± 8.78; 109.1/130.3/136.8 | 71.30 ± 2.11; 67.7/71.5/74.2A | 84.39 ± 5.61; 76.4/84.0/95.7b | 101.99 ± 4.79; 92.9/102.0/107.7A | 158.47 ± 3.52; 129.1/145.1/223.7 | 77.17 ± 3.22; 71.4/77.2/82.1a,A | 87.78 ± 2.92; 82.9/88.5/91.7b,A | 35.45 ± 2.46; 31.3/35.7/39.6A |
a,bNo significant differences between groups within one method
A,BNo significant differences between groups within one material and one position
Root mean square of deviation from each other within one group (precision) by additively manufactured bite splints in either horizontal or vertical building position and one milled material (mean ± SD; min/median/max)
| Measurement | Material | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Dental LT | Ortho Clear | Freeprint Splint | V-Splint | ProArt CAD Splint | |||||
| Position | |||||||||
| Horizontal | Vertical | Horizontal | Vertical | Horizontal | Vertical | Horizontal | Vertical | ||
| Cloud1 | 72.16 ± 3.10; 767.1/72.3/75.8a | 68.80 ± 3.90; 64.1/67.6/72.9b,c | 68.18 ± 2.13; 65.4/67.9/71.5b | 60.20 ± 1.79; 58.1/60.0/63.1d | 83.01 ± 17.27; 65.4/67.9/71.5/e | 58.97 ± 2.69; 57.0/57.8/64.0d | 82.73 ± 3.94; 77.3/82.3/89.3e,A | 59.56 ± 2.43; 55.9/59.7/62.8d | 71.01 ± 3.04; 66.4/71.2/76.4a,c |
| Cloud2 | 40.81 ± 5.01; 31.6/41.7/46.6a,b | 91.62 ± 29.91; 17.6/93.4/122.2A | 35.04 ± 3.71; 28.3/35.0/40.6c | 22.55 ± 3.37; 19.1/21.4/28.6d | 44.97 ± 5.66; 38.9/43.9/55.3a,A | 19.73 ± 2.82; 15.9/19.0/25.6d,A | 81.36 ± 2.14; 77.9/81.4/84.4A | 21.21 ± 6.31; 77.8/81.4/84.4d,A | 38.46 ± 6.01; 28.1/38.9/48.1b,c |
| GOM | 51.80 ± 8.01; 39.6/51.5/62.4a | 109.2 ± 13.5; 89.8/103.4/131.1A | 31.12 ± 3.25; 26.2/30.3/37.5b | 19.42 ± 2.62; 17.1/18.4/24.9c | 41.22 ± 8.27; 27.2/42.9/52.0A | 19.47 ± 2.82; 16.8/19.9/23.7c,A | 58.22 ± 3.53; 53.4/58.2/64.7a | 24.40 ± 2.48; 20.6/24.7/27.7d,A | 27.38 ± 7.01; 19.2/28.2/37.2b,d |
a,bNo significant differences between groups within one method
A,BNo significant differences between groups within one material and one position
Fig. 3Comparison between milled (upper) and printed (lower) intaglio surface: the limitations of the burs’ diameter are obvious for the milled splints on the incisal edges
Fig. 4Different measurement methods: cloud-to-cloud (nearest point distance) vs cloud-to-mesh (perpendicular distance)