Literature DB >> 8636168

Foreign-body reaction and the course of osteolysis after polyglycolide implants for fracture fixation: experimental study in sheep.

A Weiler1, H J Helling, U Kirch, T K Zirbes, K E Rehm.   

Abstract

Foreign-body reaction to polyglycolide (PGA) implants has been described in man. Many animal experiments have verified the mechanical properties of fixation devices made from PGA, but a significant foreign-body reaction has not been described. We studied the effect of PGA rods in 12 sheep with standardised osteochondral fractures of the medial femoral condyle fixed with uncoloured, self-reinforced PGA rods (Biofix). Radiographs were taken at intervals ranging from two weeks to two years, and the sheep were killed at intervals ranging from six to 24 months. All knees were examined histologically. Eleven of the 12 fractures healed radiologically and histologically. Moderate to severe osteolysis was seen at four to six weeks with maximum changes at 12 weeks in ten animals. Six knees showed fistula-like connections between the implant site and the joint space. Three developed synovitis, one with inflammatory changes involving the whole cartilage and one with destruction of the medial condyle. Although in our study osteochondral fractures fixed with PGA rods healed reliably, there were frequent, significant foreign-body reactions. Caution is needed when considering the use of PGA fixation devices in vulnerable regions such as the knee.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8636168

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  20 in total

1.  Short-term and long-term effects of orthopedic biodegradable implants.

Authors:  Ami R Amini; James S Wallace; Syam P Nukavarapu
Journal:  J Long Term Eff Med Implants       Date:  2011

2.  Delayed foreign-body reaction to absorbable implants in metacarpal fracture treatment.

Authors:  Panagiotis K Givissis; Stavros I Stavridis; Panayiotis J Papagelopoulos; Petros D Antonarakos; Anastasios G Christodoulou
Journal:  Clin Orthop Relat Res       Date:  2010-05-15       Impact factor: 4.176

3.  Evaluation of the 96/4 PLDLLA polymer resorbable lumbar interbody cage in a long term animal model.

Authors:  Jean Y Lazennec; Abdallah Madi; Marc A Rousseau; Bernard Roger; Gérard Saillant
Journal:  Eur Spine J       Date:  2006-05-31       Impact factor: 3.134

Review 4.  Migration of "bioabsorbable" screws in ACL repair. How much do we know? A systematic review.

Authors:  Hélder Pereira; Hélder M D Pereira; Vítor M Correlo; Joana Silva-Correia; Joaquim M Oliveira; Rui L Reis; Rui L Reis Ceng; João Espregueira-Mendes
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-02-03       Impact factor: 4.342

5.  Micro-Nanostructures of Cellulose-Collagen for Critical Sized Bone Defect Healing.

Authors:  Aja Aravamudhan; Daisy M Ramos; Jonathan Nip; Ivo Kalajzic; Sangamesh G Kumbar
Journal:  Macromol Biosci       Date:  2017-11-27       Impact factor: 4.979

6.  Quadruple Semitendinosus Graft Construct and Suspensory Button Fixation for Anterior Cruciate Ligament Reconstruction.

Authors:  Alcindo Silva; Ricardo Sampaio
Journal:  Arthrosc Tech       Date:  2015-12-10

Review 7.  [Complications with all-inside devices used in reconstructive meniscal surgery].

Authors:  P Wilmes; O Lorbach; P Brogard; R Seil
Journal:  Orthopade       Date:  2008-11       Impact factor: 1.087

Review 8.  Bioabsorbable versus metallic interference screws for graft fixation in anterior cruciate ligament reconstruction.

Authors:  Pedro Debieux; Carlos E S Franciozi; Mário Lenza; Marcel Jun Tamaoki; Robert A Magnussen; Flávio Faloppa; João Carlos Belloti
Journal:  Cochrane Database Syst Rev       Date:  2016-07-24

9.  Biomechanical evaluation of a new cross-pin technique for the fixation of different sized bone-patellar tendon-bone grafts.

Authors:  Thore Zantop; Barbara Welbers; Andre Weimann; Markus Rümmler; Jürgen Hedderich; Volker Musahl; Wolf Petersen
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-06-19       Impact factor: 4.342

Review 10.  Biomaterials-Driven Sterile Inflammation.

Authors:  Henry Chen; Devendra K Agrawal; Finosh G Thankam
Journal:  Tissue Eng Part B Rev       Date:  2021-02-23       Impact factor: 6.389

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.