Literature DB >> 8603850

Influence of fixation accuracy on threshold variability in patients with open angle glaucoma.

D B Henson1, J Evans, B C Chauhan, C Lane.   

Abstract

PURPOSE: To evaluate the contribution that fixation errors make to the overall variability of perimetric responses in patients with glaucoma.
METHODS: Frequency of seeing curves were established, with and without fixation error correction, at two locations in each of 14 patients with glaucoma and good visual acuity. One location corresponded to a relatively normal region of the visual field, whereas the second corresponded to a region in which there was a sensitivity deficit. All patients had an acuity of better than 20/63 (except one whose acuity was 20/100). The locations of the first and fourth Purkinje images of a collimated infrared source were used to give a measure of eye position, during each stimulus presentation (accuracy 10 minutes of arc).
RESULTS: Considerable variation was found in patient fixation accuracy. In the worst case, fixation was within 30 minutes of the target in only 7% of presentations whereas in the best, it was within this range in more than 60%. No relationship was found between accuracy of fixation and extent of loss. The gradient of the frequency of seeing curve was found to be shallow at regions of reduced sensitivity, a finding that supports the recognized relationship between variability and sensitivity deficit. A recalculation of the frequency of seeing curves, using only those responses in which the patient's fixation was within a specified range ( < 60 minutes of arc), did not show a meaningful reduction in variability at either location.
CONCLUSIONS: It is concluded that fixation errors, though contributing to variability, are not the major cause of the increased variability seen at locations with reduced sensitivity.

Entities:  

Mesh:

Year:  1996        PMID: 8603850

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  17 in total

Review 1.  The definition and classification of glaucoma in prevalence surveys.

Authors:  Paul J Foster; Ralf Buhrmann; Harry A Quigley; Gordon J Johnson
Journal:  Br J Ophthalmol       Date:  2002-02       Impact factor: 4.638

2.  Development and evaluation of a linear staircase strategy for the measurement of perimetric sensitivity.

Authors:  Rizwan Malik; William H Swanson; David F Garway-Heath
Journal:  Vision Res       Date:  2006-06-09       Impact factor: 1.886

3.  Variability of visual field measurements is correlated with the gradient of visual sensitivity.

Authors:  Harry J Wyatt; Mitchell W Dul; William H Swanson
Journal:  Vision Res       Date:  2007-02-23       Impact factor: 1.886

4.  Automated perimetry: using gaze-direction data to improve the estimate of scotoma edges.

Authors:  Harry J Wyatt
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-07-29       Impact factor: 4.799

5.  Evaluation of a two-stage neural model of glaucomatous defect: an approach to reduce test-retest variability.

Authors:  Fei Pan; William H Swanson; Mitchell W Dul
Journal:  Optom Vis Sci       Date:  2006-07       Impact factor: 1.973

6.  Frequency of seeing characteristics of the short wavelength sensitive visual pathway in clinically normal subjects and diabetic patients with focal sensitivity loss.

Authors:  E D Gilmore; C Hudson; R K Nrusimhadevara; P T Harvey
Journal:  Br J Ophthalmol       Date:  2005-11       Impact factor: 4.638

7.  Simulating binocular visual field status in glaucoma.

Authors:  D P Crabb; A C Viswanathan; A I McNaught; D Poinoosawmy; F W Fitzke; R A Hitchings
Journal:  Br J Ophthalmol       Date:  1998-11       Impact factor: 4.638

8.  Development and validation of a visual field cluster in retinitis pigmentosa.

Authors:  Takashi Omoto; Akio Oishi; Ryo Asaoka; Yuri Fujino; Hiroshi Murata; Keiko Azuma; Manabu Miyata; Ryo Obata; Tatsuya Inoue
Journal:  Sci Rep       Date:  2021-05-06       Impact factor: 4.379

9.  Eye movements during visual search in patients with glaucoma.

Authors:  Nicholas D Smith; Fiona C Glen; David P Crabb
Journal:  BMC Ophthalmol       Date:  2012-08-31       Impact factor: 2.209

10.  Assessing the GOANNA Visual Field Algorithm Using Artificial Scotoma Generation on Human Observers.

Authors:  Luke X Chong; Andrew Turpin; Allison M McKendrick
Journal:  Transl Vis Sci Technol       Date:  2016-09-01       Impact factor: 3.283

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.