Literature DB >> 16234454

Frequency of seeing characteristics of the short wavelength sensitive visual pathway in clinically normal subjects and diabetic patients with focal sensitivity loss.

E D Gilmore1, C Hudson, R K Nrusimhadevara, P T Harvey.   

Abstract

AIMS: To define the frequency of seeing (FOS) characteristics of the short wavelength (SW) sensitive visual pathway in clinically normal subjects and in diabetic patients with focal SW sensitivity loss.
METHODS: For clinically normal subjects, FOS was assessed at two retinal locations (4.24 degrees and 9.90 degrees eccentricity) for both white on white (WW) and SW stimulus parameters. Inter-examination variability was quantified for the clinically normal subjects only. For patients with diabetes, FOS was assessed inside an area of focal SW sensitivity loss, and at the same eccentricity in the quadrant diametrically opposite, using SW stimulus parameters only.
RESULTS: For clinically normal subjects, the group mean SW FOS slope was significantly flatter (p<0.0001) than that of WW at both locations. The coefficient of repeatability for SW FOS slope was+/-41.55 dB(-1) (relative to a group mean sensitivity of 23.98 dB(-1)) and+/-19.98 dB(-1) (group mean sensitivity 16.15 dB(-1)) for 4.24 degrees and 9.90 degrees , respectively. For the patients with diabetes, the group mean SW FOS slope was significantly flatter (p=0.020), and group mean SW threshold significantly higher (p=0.007) in the area of focal SW sensitivity loss than in that of the non-focal sensitivity loss.
CONCLUSIONS: The results of this study suggest that the clinical utility of SW automated perimetry will be limited by a greater magnitude of measurement variability, as indicated by a flatter FOS slope, compared to conventional automated perimetry.

Entities:  

Mesh:

Year:  2005        PMID: 16234454      PMCID: PMC1772939          DOI: 10.1136/bjo.2005.074682

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  29 in total

1.  Short-wavelength automated perimetry and capillary density in early diabetic maculopathy.

Authors:  A Remky; O Arend; S Hendricks
Journal:  Invest Ophthalmol Vis Sci       Date:  2000-01       Impact factor: 4.799

2.  Progressive color visual field loss in glaucoma.

Authors:  P A Sample; R N Weinreb
Journal:  Invest Ophthalmol Vis Sci       Date:  1992-05       Impact factor: 4.799

3.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

4.  Characteristics of frequency-of-seeing curves in normal subjects, patients with suspected glaucoma, and patients with glaucoma.

Authors:  B C Chauhan; J D Tompkins; R P LeBlanc; T A McCormick
Journal:  Invest Ophthalmol Vis Sci       Date:  1993-12       Impact factor: 4.799

5.  Fatigue effects during a single session of automated static threshold perimetry.

Authors:  C Hudson; J M Wild; E C O'Neill
Journal:  Invest Ophthalmol Vis Sci       Date:  1994-01       Impact factor: 4.799

Review 6.  Short wavelength automated perimetry.

Authors:  J M Wild
Journal:  Acta Ophthalmol Scand       Date:  2001-12

7.  Characteristics of frequency-of-seeing curves for a motion stimulus in glaucoma eyes, glaucoma suspect eyes, and normal eyes.

Authors:  M C Westcott; F W Fitzke; D P Crabb; R A Hitchings
Journal:  Vision Res       Date:  1999-02       Impact factor: 1.886

8.  Incidence and prevalence of short wavelength automated perimetry deficits in ocular hypertensive patients.

Authors:  S Demirel; C A Johnson
Journal:  Am J Ophthalmol       Date:  2001-06       Impact factor: 5.258

9.  Progression of early glaucomatous visual field loss as detected by blue-on-yellow and standard white-on-white automated perimetry.

Authors:  C A Johnson; A J Adams; E J Casson; J D Brandt
Journal:  Arch Ophthalmol       Date:  1993-05

10.  Differential light threshold. Short- and long-term fluctuation in patients with glaucoma, normal controls, and patients with suspected glaucoma.

Authors:  J Flammer; S M Drance; M Zulauf
Journal:  Arch Ophthalmol       Date:  1984-05
View more
  1 in total

1.  Assessment of patient opinions of different clinical tests used in the management of glaucoma.

Authors:  Stuart K Gardiner; Shaban Demirel
Journal:  Ophthalmology       Date:  2008-12       Impact factor: 12.079

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.