A paralleling technique modification to determine the bone crest level around dental implants.

Noelia Fernández-Formoso1, B Rilo, M J Mora, I Martínez-Silva, U Santana.   

Abstract

The aim of this report is two-fold. First it analyses the precision of a modification of the parallel technique that can be used in those cases with anatomical limitations. Second, it checks the influence of the reference points' definition of objects to be measured by using both the original and the modified radiographic techniques. 2 intraoral radiographs were taken of 28 implants with 2 different methods: a standard paralleling technique and a modified technique that used a smaller film and a silicone spacer to ensure parallelism. Measurements of peri-implant bone levels and implant width were made in triplicate on digitized film radiographs. The results of the peri-implant bone levels were that with the parallel method the mean was 0.44 mm and the precision was 0.43 mm, and with the modified method the mean was 0.73 mm and the precision was 0.66 mm. In addition to the correct localization of the point of reference in this study, the precision with the parallel method was 0.08 mm and with the modified method was 0.13 mm. Although it was greater with the gold standard technique than with the modified technique, precision was very high for both methods and accurate enough for clinical use.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21831979      PMCID: PMC3520342          DOI: 10.1259/dmfr/45365752

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  18 in total

1.  Evaluation of single-tooth restorations on ITI dental implants. A prospective study of 29 patients.

Authors:  L E Moberg; P A Köndell; L Kullman; A Heimdahl; G W Gynther
Journal:  Clin Oral Implants Res       Date:  1999-02       Impact factor: 5.977

2.  Mathematical analysis of projection errors in "paralleling technique" with respect to implant geometry.

Authors:  R K Schulze; B d'Hoedt
Journal:  Clin Oral Implants Res       Date:  2001-08       Impact factor: 5.977

3.  The accuracy and reliability of radiographic methods for the assessment of marginal bone level around oral implants.

Authors:  E De Smet; R Jacobs; F Gijbels; I Naert
Journal:  Dentomaxillofac Radiol       Date:  2002-05       Impact factor: 2.419

4.  Errors in radiographic assessment of marginal bone height around osseointegrated implants.

Authors:  I P Sewerin
Journal:  Scand J Dent Res       Date:  1990-10

5.  A reliable computerized method to determine the level of the radiographic alveolar crest.

Authors:  E Hausmann; K Allen; R Dunford; L Christersson
Journal:  J Periodontal Res       Date:  1989-11       Impact factor: 4.419

6.  Method for radiographic assessment of alveolar bone level at endosseous implants and abutment teeth.

Authors:  T A Larheim; H Wie; L Tveito; S Eggen
Journal:  Scand J Dent Res       Date:  1979-04

7.  Radiographic evaluation of osseointegrated implants of the jaws. Experimental study of the influence of radiographic techniques on the measurement of the relation between the implant and bone.

Authors:  L Hollender; B Rockler
Journal:  Dentomaxillofac Radiol       Date:  1980       Impact factor: 2.419

8.  Measurements of alveolar bone height at tooth and implant abutments on intraoral radiographs. A comparison of reproducibility of Eggen technique utilized with and without a bite impression.

Authors:  T A Larheim; S Eggen
Journal:  J Clin Periodontol       Date:  1982-05       Impact factor: 8.728

9.  Radiographic assessment of the marginal bone level after implant treatment: a comparison of periapical and Scanora detailed narrow beam radiography.

Authors:  S Lofthag-Hansen; C Lindh; A Petersson
Journal:  Dentomaxillofac Radiol       Date:  2003-03       Impact factor: 2.419

10.  A radiographic method for assessing changes in alveolar bone height following periodontal therapy.

Authors:  B Rosling; L Hollender; S Nyman; G Olsson
Journal:  J Clin Periodontol       Date:  1975       Impact factor: 8.728

View more
  3 in total

1.  Pose determination of a blade implant in three dimensions from a single two-dimensional radiograph.

Authors:  Paolo Toti; Antonio Barone; Simone Marconcini; Giovanni Battista Menchini-Fabris; Ranieri Martuscelli; Ugo Covani
Journal:  Dentomaxillofac Radiol       Date:  2018-01-11       Impact factor: 2.419

2.  Standardization of three-dimensional pose of cylindrical implants from intraoral radiographs: a preliminary study.

Authors:  Saverio Cosola; Paolo Toti; Miguel Peñarrocha-Diago; Ugo Covani; Bruno Carlo Brevi; David Peñarrocha-Oltra
Journal:  BMC Oral Health       Date:  2021-03-06       Impact factor: 2.757

Review 3.  Using acrylic customized X-ray positioning stents for long-term follow-up studies.

Authors:  Sherif Aly Sadek; Hisham Mohamed Abbas; Moayad Alfelali; Abdulaziz Almahdali
Journal:  Saudi Dent J       Date:  2019-10-15
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.