Uncertain value of electronic fetal monitoring in predicting cerebral palsy.

K B Nelson1, J M Dambrosia, T Y Ting, J K Grether.   

Abstract

BACKGROUND: Electronic monitoring of the fetal heart rate is commonly performed, in part to detect hypoxia during delivery that may result in brain injury. It is not know whether specific abnormalities on electronic fetal monitoring are related to the risk of cerebral palsy.
METHODS: Among 155,636 children born from 1983 through 1985 in four California counties, we identified singleton infants with birth weights of at least 2500 g who survived to three years of age and had moderate or severe cerebral palsy. The children with cerebral palsy were compared with randomly selected control children with respect to characteristics noted in the birth records.
RESULTS: Seventy-eight of 95 children with cerebral palsy and 300 of 378 controls underwent intrapartum fetal monitoring. Characteristics found to be associated with an increased risk of cerebral palsy were multiple late decelerations in the heart rate, commonly defined as slowing of the heart rate well after the onset of uterine contractions (odds ratio, 3.9; 95 percent confidence interval, 1.7 to 9.3), and decreased beat-to-beat variability of the heart rate (odds ratio, 2.7; 95 percent confidence interval, 1.1 to 5.8); there was no association between the highest or lowest fetal heart rate recorded for each child and the risk of cerebral palsy. Even after adjustment for other risk factors, the association of abnormalities on fetal monitoring with an increased risk of cerebral palsy persisted (adjusted odds ratio, 2.7; 95 percent confidence interval, 1.4 to 5.4). The 21 children with cerebral palsy who had multiple late decelerations or decreased variability in heart rate on fetal monitoring represented only 0.19 percent of singleton infants with birth weights of 2500 g or more who had these fetal-monitoring findings, for a false positive rate of 99.8 percent.
CONCLUSIONS: Specific abnormal findings on electronic monitoring of the fetal heart rate were associated with an increased risk of cerebral palsy. However, the false positive rate was extremely high. Since cesarean section is often performed when such abnormalities are noted and is associated with risk to the mother, our findings arouse concern that, if these indications were widely used, many cesarean sections would be performed without benefit and with the potential for harm.

Entities:  

Mesh:

Year:  1996        PMID: 8592523     DOI: 10.1056/NEJM199603073341001

Source DB:  PubMed          Journal:  N Engl J Med        ISSN: 0028-4793            Impact factor:   91.245


  37 in total

1.  [Differences in the likelihood of caesareans, associated with dependency on hospitals, the volume of cases and the obstetric risk].

Authors:  A Sarría-Santamera; E T López-Madurga
Journal:  Aten Primaria       Date:  2003-10-15       Impact factor: 1.137

Review 2.  Potential biomarkers for hypoxic-ischemic encephalopathy.

Authors:  L Bennet; L Booth; A J Gunn
Journal:  Semin Fetal Neonatal Med       Date:  2010-06-19       Impact factor: 3.926

3.  Optode Design Space Exploration for Clinically-robust Non-invasive Fetal Oximetry.

Authors:  Daniel D Fong; Vivek J Srinivasan; Kourosh Vali; Soheil Ghiasi
Journal:  ACM Trans Embed Comput Syst       Date:  2019-10-08       Impact factor: 1.193

4.  Cesarean section for suspected fetal distress, continuous fetal heart monitoring and decision to delivery time.

Authors:  K K Roy; Jinee Baruah; Sunesh Kumar; A K Deorari; J B Sharma; Debjyoti Karmakar
Journal:  Indian J Pediatr       Date:  2009-02-04       Impact factor: 1.967

5.  Perinatal risk factors for severe injury in neonates treated with whole-body hypothermia for encephalopathy.

Authors:  Christopher P Wayock; Rachel L Meserole; Suchi Saria; Jacky M Jennings; Thierry A G M Huisman; Frances J Northington; Ernest M Graham
Journal:  Am J Obstet Gynecol       Date:  2014-03-18       Impact factor: 8.661

Review 6.  Continuous cardiotocography (CTG) as a form of electronic fetal monitoring (EFM) for fetal assessment during labour.

Authors:  Zarko Alfirevic; Declan Devane; Gillian Ml Gyte; Anna Cuthbert
Journal:  Cochrane Database Syst Rev       Date:  2017-02-03

7.  A prospective cohort study of fetal heart rate monitoring: deceleration area is predictive of fetal acidemia.

Authors:  Alison G Cahill; Methodius G Tuuli; Molly J Stout; Julia D López; George A Macones
Journal:  Am J Obstet Gynecol       Date:  2018-02-01       Impact factor: 8.661

8.  Electronic fetal monitoring, cerebral palsy, and caesarean section: assumptions versus evidence.

Authors:  Karin B Nelson; Thomas P Sartwelle; Dwight J Rouse
Journal:  BMJ       Date:  2016-12-01

9.  Electronic Fetal Monitoring: A Defense Lawyer's View.

Authors:  Thomas P Sartwelle
Journal:  Rev Obstet Gynecol       Date:  2012

10.  S1-Guideline on the Use of CTG During Pregnancy and Labor: Long version - AWMF Registry No. 015/036.

Authors: 
Journal:  Geburtshilfe Frauenheilkd       Date:  2014-08       Impact factor: 2.915

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.