Cone-beam CT for radiotherapy applications.

P S Cho1, R H Johnson, T W Griffin.   

Abstract

Clinical implementation of cone-beam tomography has been hampered by the lack of two-dimensional electronic x-ray detectors that can encompass the full width of the body. We encountered the undersized detector problem in our development of a cone-beam CT system for radiotherapy applications. In order to mitigate the problem, we developed an algorithm which permits an increased reconstruction volume to be imaged using a detector of a given size. We describe the algorithm and report on its implementation using a radiotherapy simulator configured with a digital fluorography unit.

Mesh:

Year:  1995        PMID: 8587937     DOI: 10.1088/0031-9155/40/11/007

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  21 in total

1.  Accuracy estimation for projection-to-volume targeting during rotational therapy: a feasibility study.

Authors:  Yong Long; Jeffrey A Fessler; James M Balter
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

2.  Monte Carlo evaluation of scatter mitigation strategies in cone-beam CT.

Authors:  Dimitrios Lazos; Jeffrey F Williamson
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

3.  Cone beam breast CT with a high pitch (75 μm), thick (500 μm) scintillator CMOS flat panel detector: visibility of simulated microcalcifications.

Authors:  Youtao Shen; Yuncheng Zhong; Chao-Jen Lai; Tianpeng Wang; Chris C Shaw
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

4.  Towards the clinical implementation of iterative low-dose cone-beam CT reconstruction in image-guided radiation therapy: cone/ring artifact correction and multiple GPU implementation.

Authors:  Hao Yan; Xiaoyu Wang; Feng Shi; Ti Bai; Michael Folkerts; Laura Cervino; Steve B Jiang; Xun Jia
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

5.  Calibration of cone beam CT using relative attenuation ratio for quantitative assessment of bone density: a small animal study.

Authors:  Yifei Liu; Tobias Bäuerle; Leyun Pan; Antonia Dimitrakopoulou-Strauss; Ludwig G Strauss; Christian Heiss; Reinhard Schnettler; Wolfhard Semmler; Liji Cao
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-12-08       Impact factor: 2.924

6.  A practical cone-beam CT scatter correction method with optimized Monte Carlo simulations for image-guided radiation therapy.

Authors:  Yuan Xu; Ti Bai; Hao Yan; Luo Ouyang; Arnold Pompos; Jing Wang; Linghong Zhou; Steve B Jiang; Xun Jia
Journal:  Phys Med Biol       Date:  2015-04-10       Impact factor: 3.609

7.  Four-dimensional volume-of-interest reconstruction for cone-beam computed tomography-guided radiation therapy.

Authors:  Moiz Ahmad; Peter Balter; Tinsu Pan
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

8.  Optimization-based image reconstruction from sparse-view data in offset-detector CBCT.

Authors:  Junguo Bian; Jiong Wang; Xiao Han; Emil Y Sidky; Lingxiong Shao; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2012-12-21       Impact factor: 3.609

9.  CBCT-based synthetic CT generation using deep-attention cycleGAN for pancreatic adaptive radiotherapy.

Authors:  Yingzi Liu; Yang Lei; Tonghe Wang; Yabo Fu; Xiangyang Tang; Walter J Curran; Tian Liu; Pretesh Patel; Xiaofeng Yang
Journal:  Med Phys       Date:  2020-03-28       Impact factor: 4.071

10.  Dedicated cone-beam breast CT using laterally-shifted detector geometry: Quantitative analysis of feasibility for clinical translation.

Authors:  Srinivasan Vedantham; Hsin-Wu Tseng; Souleymane Konate; Linxi Shi; Andrew Karellas
Journal:  J Xray Sci Technol       Date:  2020       Impact factor: 1.535

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.