Literature DB >> 8572066

Determination of the position of nucleus cochlear implant electrodes in the inner ear.

M W Skinner1, D R Ketten, M W Vannier, G A Gates, R L Yoffie, W A Kalender.   

Abstract

Accurate determination of intracochlear electrode position in patients with cochlear implants could provide a basis for detecting migration of the implant and could aid in the selection of stimulation parameters for sound processor programming. New computer algorithms for submillimeter resolution and 3-D reconstruction from spiral computed tomographic (CT) scans now make it possible to accurately determine the position of implanted electrodes within the cochlear canal. The accuracy of these algorithms was tested using an electrode array placed in a phantom model. Measurements of electrode length and interelectrode distance from spiral CT scan reconstructions were in close agreement with those from stereo microscopy. Although apparent electrode width was increased on CT scans due to partial volume averaging, a correction factor was developed for measurements from conventional radiographs and an expanded CT absorption value scale added to detect the presence of platinum electrodes and wires. The length of the cochlear canal was calculated from preoperative spiral CT scans for one patient, and the length of insertion of the electrode array was calculated from her postoperative spiral CT scans. The cross-sectional position of electrodes in relation to the outer bony wall and modiolus was measured and plotted as a function of distance with the electrode width correction applied.

Entities:  

Mesh:

Year:  1994        PMID: 8572066

Source DB:  PubMed          Journal:  Am J Otol        ISSN: 0192-9763


  12 in total

1.  Perceptual "vowel spaces" of cochlear implant users: implications for the study of auditory adaptation to spectral shift.

Authors:  J D Harnsberger; M A Svirsky; A R Kaiser; D B Pisoni; R Wright; T A Meyer
Journal:  J Acoust Soc Am       Date:  2001-05       Impact factor: 1.840

2.  Complication of cochlear implantation surgery.

Authors:  Michael A Mecca; William Wagle; Allison Lupinetti; Steven Parnes
Journal:  AJNR Am J Neuroradiol       Date:  2003 Nov-Dec       Impact factor: 3.825

3.  Modelling encapsulation tissue around cochlear implant electrodes.

Authors:  T Hanekom
Journal:  Med Biol Eng Comput       Date:  2005-01       Impact factor: 2.602

4.  Use of computed tomography scans for cochlear implants.

Authors:  Bruce R Whiting; Timothy A Holden; Barry S Brunsden; Charles C Finley; Margaret W Skinner
Journal:  J Digit Imaging       Date:  2008-09       Impact factor: 4.056

5.  High-resolution secondary reconstructions with the use of flat panel CT in the clinical assessment of patients with cochlear implants.

Authors:  M S Pearl; A Roy; C J Limb
Journal:  AJNR Am J Neuroradiol       Date:  2013-12-26       Impact factor: 3.825

6.  Self-Selection of Frequency Tables with Bilateral Mismatches in an Acoustic Simulation of a Cochlear Implant.

Authors:  Matthew B Fitzgerald; Ksenia Prosolovich; Chin-Tuan Tan; E Katelyn Glassman; Mario A Svirsky
Journal:  J Am Acad Audiol       Date:  2017-05       Impact factor: 1.664

Review 7.  Consensus panel on a cochlear coordinate system applicable in histologic, physiologic, and radiologic studies of the human cochlea.

Authors:  Berit M Verbist; Margaret W Skinner; Lawrence T Cohen; Patricia A Leake; Chris James; Colette Boëx; Timothy A Holden; Charles C Finley; Peter S Roland; J Thomas Roland; Matt Haller; Jim F Patrick; Claude N Jolly; Mike A Faltys; Jeroen J Briaire; Johan H M Frijns
Journal:  Otol Neurotol       Date:  2010-07       Impact factor: 2.311

8.  Depth of electrode insertion and postoperative performance in humans with cochlear implants: a histopathologic study.

Authors:  Joonhan Lee; Joseph B Nadol; Donald K Eddington
Journal:  Audiol Neurootol       Date:  2010-03-04       Impact factor: 1.854

9.  Effects of stimulation level and electrode pairing on the binaural interaction component of the electrically evoked auditory brain stem response.

Authors:  Shuman He; Carolyn J Brown; Paul J Abbas
Journal:  Ear Hear       Date:  2010-08       Impact factor: 3.570

10.  An evaluation framework for research platforms to advance cochlear implant/hearing aid technology: A case study with CCi-MOBILE.

Authors:  Ram C M C Shekar; John H L Hansen
Journal:  J Acoust Soc Am       Date:  2021-01       Impact factor: 1.840

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.