Literature DB >> 856028

Evaluation of the Autobac 1 susceptibility testing system in a clinical diagnostic laboratory.

M Mogyoros, J R Morgan, J A Smith.   

Abstract

The Autobac 1 system was compared to the disk diffusion and agar dilution methods. Overall, there was good correlation; however, certain antibiotic/bacterial combinations gave unreliable results. In particular, unreliable results were obtained against staphylococci with penicillins, aerobic gram-negative rods with cephalothin, and enterococci with cephalothin and clindamycin.

Entities:  

Mesh:

Substances:

Year:  1977        PMID: 856028      PMCID: PMC352061          DOI: 10.1128/AAC.11.4.750

Source DB:  PubMed          Journal:  Antimicrob Agents Chemother        ISSN: 0066-4804            Impact factor:   5.191


  4 in total

Review 1.  Pharmacokinetics and clinical use of cephalosporin antibiotics.

Authors:  C H Nightingale; D S Greene; R Quintiliani
Journal:  J Pharm Sci       Date:  1975-12       Impact factor: 3.534

2.  Laboratory evaluation of a rapid, automatic susceptibility testing system: report of a collaborative study.

Authors:  C Thornsberry; T L Gavan; J C Sherris; A Balows; J M Matsen; L D Sabath; F Schoenknecht; L D Thrupp; J A Washington
Journal:  Antimicrob Agents Chemother       Date:  1975-04       Impact factor: 5.191

Review 3.  Absorption, distribution, excretion and fate of kanamycin.

Authors:  C M Kunin
Journal:  Ann N Y Acad Sci       Date:  1966-06-14       Impact factor: 5.691

4.  Pharmacokinetics of ampicillin trihydrate, sodium ampicillin, and sodium dicloxacillin following intramuscular injection.

Authors:  J T Doluisio; J C LaPiana; L W Dittert
Journal:  J Pharm Sci       Date:  1971-05       Impact factor: 3.534

  4 in total
  8 in total

1.  Comparison of ampicillin with clindamycin plus gentamicin in the treatment of postpartum uterine infection.

Authors:  D G Pond; P E Bernstein; K R Love; J R Morgan; H Velland; J A Smith
Journal:  Can Med Assoc J       Date:  1979-03-03       Impact factor: 8.262

2.  Use of the Autobac system for detection of methicillin-resistant Staphylococcus aureus.

Authors:  Y de Rautlin de la Roy; E Chevalier-Burbaud; S Pannetier; F Souchaud
Journal:  J Clin Microbiol       Date:  1985-09       Impact factor: 5.948

3.  Apparent colistin-related false sensitivity with the Autobac I system.

Authors:  L Duckenfield; M Wadke; J K Ashton
Journal:  J Clin Microbiol       Date:  1980-10       Impact factor: 5.948

4.  Rapid antimicrobial susceptibility test using tetrazolium reduction.

Authors:  R C Bartlett; M F Mazens
Journal:  Antimicrob Agents Chemother       Date:  1979-06       Impact factor: 5.191

5.  Rate of penicillin killing of Staphylococcus aureus and Autobac 1 susceptibility test results.

Authors:  J A Harris; D Furtado
Journal:  J Clin Microbiol       Date:  1982-02       Impact factor: 5.948

6.  Detection of methicillin-resistant Staphylococcus aureus by microdilution and disk elution susceptibility systems.

Authors:  J M Boyce; L S Lytle; D A Walsh
Journal:  J Clin Microbiol       Date:  1984-12       Impact factor: 5.948

7.  Australian evaluation of Autobac I with suggested interpretive and technical modifications.

Authors:  G R Funnell; M D Guinness
Journal:  Antimicrob Agents Chemother       Date:  1979-09       Impact factor: 5.191

8.  Two-hospital study of Staphylococcus aureus susceptibility to penicillin and ampicillin by Autobac I.

Authors:  P C Harris; L B Sealey
Journal:  Antimicrob Agents Chemother       Date:  1980-12       Impact factor: 5.191

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.