Literature DB >> 8554929

Method specificity of non-invasive blood pressure measurement: oscillometry and finger pulse pressure vs acoustic methods.

C De Mey1, V Schroeter, R Butzer, S Roll, G G Belz.   

Abstract

1. The agreement of blood pressure measurements by stethoscope auscultation (SBPa, DBPa-IV and DBPa-V), oscillometry (Dinamap; SBPo, and DBPo) and digital photoplethysmography (Finapres; SBPf, and DBPf) with the graphical analysis of the analogue microphone signals of vascular wall motion sound (SBPg and DBPg) was evaluated in eight healthy subjects in the presence of responses to the intravenous infusion of 1 microgram min-1 isoprenaline. 2. In general, there was good agreement between the SBP/DBP-measurements based on auscultatory Korotkoff-I- and IV-criteria and the reference method; the average method difference in estimating the isoprenaline responses for SBPa-SBPg was: -1.1, 95% CI: -5.4 to 3.1 mm Hg with a within-subject between-method repeatability coefficient (REP) of 11.6 mm Hg and for DBPa-IV-DBPg: 3.5, 95% CI: -0.5 to 6.5 mm Hg, REP: 11.5 mm Hg. The ausculatation of Korotkoff-V substantially overestimated the isoprenaline induced reduction of DBP: method difference DBPa-V-DBPg: -11.3, 95% CI: -17.8 to -4.7 mm Hg, REP: 31.8 mm Hg. 3. Oscillometry yielded good approximations for the SBP response to isoprenaline (average method difference SBPo-SBPg: -2.9, 95% CI: -9.0 to 3.3 mm Hg, REP: 17.6 mm Hg) but was poorly sensitive with regard to the DBP responses: method difference DBPo-DBPg: 6.5, 95% CI: -1.3 to 14.3 mm Hg, REP: 25.7 mm Hg. 4. Whilst the finger pulse pressure agreed well with regard to DBP (method difference for the DBP responses to isoprenaline: DBPf-DBPg: 1.8, 95% CI: -5.1 to 8.6 mm Hg, REP: 18.5 mm Hg) it was rather unsatisfactory with regard to SBP (method difference SBPf-SBPg: -14.1, 95% CI: -28.2 to -0.1 mm Hg, REP: 49.9 mm Hg).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8554929      PMCID: PMC1365146          DOI: 10.1111/j.1365-2125.1995.tb04549.x

Source DB:  PubMed          Journal:  Br J Clin Pharmacol        ISSN: 0306-5251            Impact factor:   4.335


  18 in total

1.  Continuous, real-time, noninvasive monitor of blood pressure: Penaz methodology applied to the finger.

Authors:  R D Boehmer
Journal:  J Clin Monit       Date:  1987-10

2.  Wideband external pulse recording during cuff deflation: a new technique for evaluation of the arterial pressure pulse and measurement of blood pressure.

Authors:  S G Blank; J E West; F B Müller; R J Cody; G A Harshfield; M S Pecker; J H Laragh; T G Pickering
Journal:  Circulation       Date:  1988-06       Impact factor: 29.690

3.  Development and evaluation of an impedance cardiac output system.

Authors:  W G Kubicek; J N Karnegis; R P Patterson; D A Witsoe; R H Mattson
Journal:  Aerosp Med       Date:  1966-12

4.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

5.  Noninvasive automatic determination of mean arterial pressure.

Authors:  M Ramsey
Journal:  Med Biol Eng Comput       Date:  1979-01       Impact factor: 2.602

6.  Method specificity of the auscultatory estimates of the inodilatory reduction of diastolic blood pressure based on Korotkoff IV and V criteria.

Authors:  C De Mey
Journal:  Br J Clin Pharmacol       Date:  1995-05       Impact factor: 4.335

7.  In search of Korotkoff.

Authors:  M Laher; E O'Brien
Journal:  Br Med J (Clin Res Ed)       Date:  1982 Dec 18-25

8.  [Indirect measurement of blood pressure in resting and exercising subjects by analysis of Korotkov sound pattern].

Authors:  B Bertram; E L von Wallenberg; J D Meyer-Erkelenz
Journal:  Z Kardiol       Date:  1982-10

9.  Tissue hypoxia distal to a Peñaz finger blood pressure cuff.

Authors:  J S Gravenstein; D A Paulus; J Feldman; G McLaughlin
Journal:  J Clin Monit       Date:  1985-04

10.  Finger systolic pressure: its use in screening for hypertension and monitoring.

Authors:  A Close; G Hamilton; S Muriss
Journal:  Br Med J (Clin Res Ed)       Date:  1986-09-27
View more
  1 in total

1.  Evaluation of noninvasive blood pressure recording by photoplethysmography in clinical studies using angiotensin challenges.

Authors:  T Buclin; C Buchwalder-Csajka; H R Brunner; J Biollaz
Journal:  Br J Clin Pharmacol       Date:  1999-10       Impact factor: 4.335

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.