The elevated-rim acetabular liner in total hip arthroplasty: relationship to postoperative dislocation.

T K Cobb1, B F Morrey, D M Ilstrup.   

Abstract

Although an acetabular component with an elevated rim is thought to improve the postoperative stability of a total hip prosthesis, the actual clinical value has not yet been demonstrated. To address this question, we reviewed the results of 5167 total hip arthroplasties that had been performed at our institution from April 1, 1985, through December 31, 1991. The prostheses included 2469 acetabular components with an elevated-rim liner (10 degrees of elevation) and 2698 with a standard liner. The cumulative probability of dislocation was estimated as a function of time since the operation with use of the Kaplan-Meier survivorship method. Forty-eight of the 2469 hips that had the elevated-rim acetabular liner dislocated within two years, compared with 101 of the 2698 hips that had the standard acetabular liner. The two-year probability of dislocation was 2.19 per cent for the hips with the elevated-rim liner and 3.85 per cent for those with the standard liner (p = 0.001). A similar trend was seen at five years; however, because of a smaller sample the difference was not significant. Increased stability at two years was also demonstrated for the hips with the elevated-rim liner when the hips were analyzed according to the operative approach, the mode of fixation, the sex of the patient, and the type of total hip arthroplasty (primary or revision). Although these data demonstrate improved stability after total hip arthroplasty when an elevated liner is used, particularly in hips that are at greater risk for dislocation of the prosthesis, the long-term effect of this elevated liner on wear and loosening remains unknown but is of considerable concern. The elevated liner deserves additional study to clarify its effect on wear and loosening.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8550683     DOI: 10.2106/00004623-199601000-00011

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  30 in total

1.  Mid-term results of large diameter heads on cross-linked polyethylene liners in total hip replacement.

Authors:  Bhavesh Sachde; Nikunj D Maru
Journal:  J Clin Orthop Trauma       Date:  2012-10-17

2.  Are Hooded, Crosslinked Polyethylene Liners Associated with a Reduced Risk of Revision After THA?

Authors:  Adrian Bauze; Somen Agrawal; Alana Cuthbert; Richard de Steiger
Journal:  Clin Orthop Relat Res       Date:  2019-06       Impact factor: 4.176

3.  Use of a dual mobility socket to manage total hip arthroplasty instability.

Authors:  Olivier Guyen; Vincent Pibarot; Gualter Vaz; Christophe Chevillotte; Jacques Béjui-Hugues
Journal:  Clin Orthop Relat Res       Date:  2008-09-09       Impact factor: 4.176

4.  Do large femoral heads reduce the risks of impingement in total hip arthroplasty with optimal and non-optimal cup positioning?

Authors:  Gianluca Cinotti; Niccolò Lucioli; Andrea Malagoli; Carlo Calderoli; Ferdinando Cassese
Journal:  Int Orthop       Date:  2010-02-17       Impact factor: 3.075

5.  Using nonlinear finite element models to analyse stress distribution during subluxation and torque required for dislocation of newly developed total hip structure after prosthetic impingement.

Authors:  Wei-Min Chi; Chien-Chung Lin; Ying-Jui Ho; Hsiao-Che Lin; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2017-07-01       Impact factor: 2.602

6.  Effects of design parameters of total hip components on the impingement angle and determination of the preferred liner skirt shape with an adequate oscillation angle.

Authors:  Hsiao-Che Lin; Wei-Min Chi; Ying-Jui Ho; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2012-11-29       Impact factor: 2.602

7.  Modified posterior soft tissue repair for the prevention of early postoperative dislocation in total hip arthroplasty.

Authors:  Yuntong Zhang; Yang Tang; Chuncai Zhang; Xue Zhao; Yang Xie; Shuogui Xu
Journal:  Int Orthop       Date:  2013-04-03       Impact factor: 3.075

8.  The unstable total hip replacement.

Authors:  F D'Angelo; L Murena; G Zatti; P Cherubino
Journal:  Indian J Orthop       Date:  2008-07       Impact factor: 1.251

9.  Surface Roughness of CoCr and ZrO(2) Femoral Heads with Metal Transfer: A Retrieval and Wear Simulator Study.

Authors:  Alan W Eberhardt; R Travis McKee; John M Cuckler; Donald W Peterson; Preston R Beck; Jack E Lemons
Journal:  Int J Biomater       Date:  2009-07-01

10.  Direction of hip arthroplasty dislocation in patients with femoral neck fractures.

Authors:  Anders Enocson; Gunilla Lapidus; Hans Törnkvist; Jan Tidermark; Lasse J Lapidus
Journal:  Int Orthop       Date:  2010-01-22       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.