PURPOSE: To determine the accuracy of T1-weighted fat-suppressed (FS) three-dimensional (3D) fast low-angle shot (FLASH) magnetic resonance (MR) imaging for the detection of articular cartilage abnormalities of the patellofemoral joint. MATERIALS AND METHODS: Forty-one patients with suspected internal derangement of the knee were examined with a T1-weighted FS 3D FLASH sequence and subsequently underwent arthroscopy. The patellofemoral articular cartilage was graded blindly on both the MR and arthroscopic images with a modification of the Noyes classification scheme. RESULTS: For the detection of abnormal articular cartilage of the patellofemoral joint with the FS 3D FLASH sequence, sensitivity was 81%, specificity was 97%, and accuracy was 97%. Of the lesions detected on MR images, 77% were graded identically on MR and arthroscopic images. For the remaining 23%, MR imaging and arthroscopic ratings were within one grade of each other. CONCLUSION: T1-weighted FS 3D FLASH imaging is accurate for the detection and grading of articular cartilage abnormalities of the patellofemoral joint.
PURPOSE: To determine the accuracy of T1-weighted fat-suppressed (FS) three-dimensional (3D) fast low-angle shot (FLASH) magnetic resonance (MR) imaging for the detection of articular cartilage abnormalities of the patellofemoral joint. MATERIALS AND METHODS: Forty-one patients with suspected internal derangement of the knee were examined with a T1-weighted FS 3D FLASH sequence and subsequently underwent arthroscopy. The patellofemoral articular cartilage was graded blindly on both the MR and arthroscopic images with a modification of the Noyes classification scheme. RESULTS: For the detection of abnormal articular cartilage of the patellofemoral joint with the FS 3D FLASH sequence, sensitivity was 81%, specificity was 97%, and accuracy was 97%. Of the lesions detected on MR images, 77% were graded identically on MR and arthroscopic images. For the remaining 23%, MR imaging and arthroscopic ratings were within one grade of each other. CONCLUSION: T1-weighted FS 3D FLASH imaging is accurate for the detection and grading of articular cartilage abnormalities of the patellofemoral joint.
Authors: Toby O Smith; Benjamin T Drew; Andoni P Toms; Simon T Donell; Caroline B Hing Journal: Knee Surg Sports Traumatol Arthrosc Date: 2012-01-24 Impact factor: 4.342
Authors: Won C Bae; Jerry R Dwek; Richard Znamirowski; Sheronda M Statum; Juan C Hermida; Darryl D D'Lima; Robert L Sah; Jiang Du; Christine B Chung Journal: Radiology Date: 2010-03 Impact factor: 11.105
Authors: H Shao; E Y Chang; C Pauli; S Zanganeh; W Bae; C B Chung; G Tang; J Du Journal: Osteoarthritis Cartilage Date: 2015-09-14 Impact factor: 6.576
Authors: Peter R Kornaat; Ruth Y T Ceulemans; Herman M Kroon; Naghmeh Riyazi; Margreet Kloppenburg; Wayne O Carter; Thasia G Woodworth; Johan L Bloem Journal: Skeletal Radiol Date: 2004-10-08 Impact factor: 2.199
Authors: Christoph Stehling; Hans Liebl; Roland Krug; Nancy E Lane; Michael C Nevitt; John Lynch; Charles E McCulloch; Thomas M Link Journal: Radiology Date: 2009-12-17 Impact factor: 11.105