Literature DB >> 8521124

Influence of light intensity on polymerization shrinkage and integrity of restoration-cavity interface.

A J Feilzer1, L H Dooren, A J de Gee, C L Davidson.   

Abstract

The results of this study showed that the use of high intensity curing light units negatively affected the integrity of the restoration-cavity interface in class V restorations This is explained by the high reaction rates of light curing resin composites. The interfacial integrity was better preserved with low light intensity as it extends the visco-elastic stage of the setting materials, thereby moderating the setting stress development. The ultimate polymerization shrinkages for both conditions were equal, which suggested equal degrees of conversion and thus equal material properties. The results may alleviate the trend in using higher intensity light curing units and in particular the development of units with laser beams in an attempt to further increase conversion rates.

Mesh:

Substances:

Year:  1995        PMID: 8521124     DOI: 10.1111/j.1600-0722.1995.tb00033.x

Source DB:  PubMed          Journal:  Eur J Oral Sci        ISSN: 0909-8836            Impact factor:   2.612


  25 in total

1.  An In-Vitro Comparison of Micro Leakage Between Two Posterior Composites Restored with Different Layering Techniques Using Two Different LED Modes.

Authors:  Nikhil Relhan; K C Ponnappa; Ashima Relhan; Anurag Jain; Priyanka Gupta
Journal:  J Clin Diagn Res       Date:  2015-05-01

2.  In vivo interfacial adaptation of class II resin composite restorations with and without a flowable resin composite liner.

Authors:  Anders Lindberg; J W V van Dijken; P Hörstedt
Journal:  Clin Oral Investig       Date:  2005-04-07       Impact factor: 3.573

3.  Effect of power density of curing unit, exposure duration, and light guide distance on composite depth of cure.

Authors:  Anders Lindberg; Anne Peutzfeldt; Jan W V van Dijken
Journal:  Clin Oral Investig       Date:  2005-04-07       Impact factor: 3.573

4.  Is the soft-start polymerisation concept still relevant for modern curing units?

Authors:  Nicoleta Ilie; Esther Jelen; Reinhard Hickel
Journal:  Clin Oral Investig       Date:  2009-11-24       Impact factor: 3.573

5.  Effect of light polymerization time, mode, and thermal and mechanical load cycling on microleakage in resin composite restorations.

Authors:  Giulliana Panfiglio Soares; Glaucia Maria Bovi Ambrosano; Debora Alves Nunes Leite Lima; Giselle Maria Marchi; Lourenço Correr-Sobrinho; José Roberto Lovadino; Flávio Henrique Baggio Aguiar
Journal:  Lasers Med Sci       Date:  2013-01-13       Impact factor: 3.161

6.  Effect of hydrophobic surface treated fumed silica fillers on a one-bottle etch and rinse model dental adhesive.

Authors:  Jing Wang; Qingsong Yu; Zhiyuan Yang
Journal:  J Mater Sci Mater Med       Date:  2017-12-23       Impact factor: 3.896

7.  Effects of different light curing units/modes on the microleakage of flowable composite resins.

Authors:  A Ruya Yazici; Cigdem Celik; Berrin Dayangac; Gul Ozgunaltay
Journal:  Eur J Dent       Date:  2008-10

8.  A clinical survey of the output intensity of 200 light curing units in dental offices across Maharashtra.

Authors:  Vivek Hegde; Sameer Jadhav; Gayatri B Aher
Journal:  J Conserv Dent       Date:  2009-07

9.  Evaluation of depth of cure and knoop hardness in a dental composite, photo-activated using different methods.

Authors:  Mithra N Hegde; Priyadarshini Hegde; Babita Malhan
Journal:  J Conserv Dent       Date:  2008-04

10.  Shrinkage Stresses Generated during Resin-Composite Applications: A Review.

Authors:  Luis Felipe J Schneider; Larissa Maria Cavalcante; Nick Silikas
Journal:  J Dent Biomech       Date:  2009-09-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.