Literature DB >> 23314786

Effect of light polymerization time, mode, and thermal and mechanical load cycling on microleakage in resin composite restorations.

Giulliana Panfiglio Soares1, Glaucia Maria Bovi Ambrosano, Debora Alves Nunes Leite Lima, Giselle Maria Marchi, Lourenço Correr-Sobrinho, José Roberto Lovadino, Flávio Henrique Baggio Aguiar.   

Abstract

This study evaluated the effect of polymerization mode and time and thermal and mechanical loading cycling (TMC) on microleakage in composite resin restorations. One hundred and eighty cavities were prepared and randomly divided according to the light curing time (20, 40, or 60 s), modes (quartz-tungsten-halogen (QTH)-420 mW/cm(2), LED 2 (2nd degree generation)-1,100 mW/cm(2), or LED 3 (3rd degree generation)-700 mW/cm(2)), and TMC. Following standard restorative procedures, the samples were prepared for analysis in an absorbance spectrophotometer. All results were statistically analyzed using the three-way ANOVA and Tukey test (p ≤ 0.05). The results revealed that the groups QTH and LED 3 submitted to TMC showed higher microleakage than those that were not submitted to TMC. Only for LED 3, 60 s showed higher microleakage than 20 s. For LED 2 and QTH, there were no differences between the times. QTH showed lower microleakage means than LED 2, when photoactivated for 20 s, without TMC. When photoactivated for 60 s, QTH showed lower microleakage means than LED 3, for the groups with or without TMC. It was concluded that TMC, the increase in polymerization time, and the irradiance were factors that may increase the marginal microleakage of class II cavities.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23314786     DOI: 10.1007/s10103-012-1244-7

Source DB:  PubMed          Journal:  Lasers Med Sci        ISSN: 0268-8921            Impact factor:   3.161


  48 in total

1.  Comparison of three different preparation methods in the improvement of sealant retention.

Authors:  Laura Camacho Castro; Ana Claudia Galvão
Journal:  J Clin Pediatr Dent       Date:  2004       Impact factor: 1.065

2.  Influence of thermal and mechanical load cycling on microtensile bond strengths of total and self-etching adhesive systems.

Authors:  Fabio Hiroyuki Ogata Mitsui; Alessandra Rezende Peris; Andrea Nóbrega Cavalcanti; Giselle Maria Marchi; Luiz André Freire Pimenta
Journal:  Oper Dent       Date:  2006 Mar-Apr       Impact factor: 2.440

3.  The elastic moduli across various types of resin/dentin interfaces.

Authors:  Pong Pongprueksa; Watcharaporn Kuphasuk; Pisol Senawongse
Journal:  Dent Mater       Date:  2008-03-04       Impact factor: 5.304

4.  Do dental composites always shrink toward the light?

Authors:  A Versluis; D Tantbirojn; W H Douglas
Journal:  J Dent Res       Date:  1998-06       Impact factor: 6.116

5.  In vitro evaluation of marginal and internal adaptation of class II resin composite restorations after thermal and occlusal stressing.

Authors:  D Dietschi; D Herzfeld
Journal:  Eur J Oral Sci       Date:  1998-12       Impact factor: 2.612

6.  Effect of preheating resin composite and light-curing units on the microleakage of Class II restorations submitted to thermocycling.

Authors:  R E Agostinho dos Santos; A F Lima; G P Soares; G M B Ambrosano; G M Marchi; J R Lovadino; F H B Aguiar
Journal:  Oper Dent       Date:  2011-03-24       Impact factor: 2.440

7.  Composite wall-to-wall polymerization contraction in dentin cavities treated with various bonding agents.

Authors:  K D Jörgensen; K Itoh; E C Munksgaard; E Asmussen
Journal:  Scand J Dent Res       Date:  1985-06

8.  Elimination of polymerization stresses at the margins of posterior composite resin restorations: a new restorative technique.

Authors:  E Lutz; I Krejci; T R Oldenburg
Journal:  Quintessence Int       Date:  1986-12       Impact factor: 1.677

9.  Bovine teeth as possible substitutes in the adhesion test.

Authors:  I Nakamichi; M Iwaku; T Fusayama
Journal:  J Dent Res       Date:  1983-10       Impact factor: 6.116

10.  Influence of photoinitiator type on the rate of polymerization, degree of conversion, hardness and yellowing of dental resin composites.

Authors:  Luis Felipe J Schneider; Carmem S C Pfeifer; Simonides Consani; Scott A Prahl; Jack L Ferracane
Journal:  Dent Mater       Date:  2008-03-05       Impact factor: 5.304

View more
  4 in total

1.  Comparison of microleakage in Class II cavities restored with silorane-based and methacrylate-based composite resins using different restorative techniques over time.

Authors:  Kazem Khosravi; Seyed-Mostafa Mousavinasab; Mahsa Sahraneshin Samani
Journal:  Dent Res J (Isfahan)       Date:  2015 Mar-Apr

2.  Effect of thermocycling and varying polymerization techniques on the restorative interface of class V cavities restored with different composite resin systems.

Authors:  Jefferson-Ricardo Pereira; Lindomar-Corrêa Júnior; Marcus-Vinicius-Reis Só; Newton-Fahl Júnior
Journal:  J Clin Exp Dent       Date:  2017-03-01

3.  Physical and photoelastic properties of bulk-fill and conventional composites.

Authors:  Renata Pereira; Maria Cecília Caldas Giorgi; Rodrigo Barros Esteves Lins; Jéssica Dias Theobaldo; Débora Alves Nunes Leite Lima; Giselle Maria Marchi; Flávio Henrique Baggio Aguiar
Journal:  Clin Cosmet Investig Dent       Date:  2018-12-12

4.  Microleakage and Bacterial Adhesion with Three Restorative Materials Used to Seal Screw-access Channels of Implant Abutments: An In vitro Study.

Authors:  Firas Khalid AlQarawi; Baneen Mansour AlShammasi; Zainab Ahmed AlBasry; Heba Zaki AlAwami; Doaa Mostafa AlEraky; Reem Yussuf AlJindan; Hamad Saleh Alrumaih; Faris Abdullah Alshahrani
Journal:  Saudi J Med Med Sci       Date:  2021-09-04
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.