Literature DB >> 15815922

Effect of power density of curing unit, exposure duration, and light guide distance on composite depth of cure.

Anders Lindberg1, Anne Peutzfeldt, Jan W V van Dijken.   

Abstract

This in vitro study compared the depth of cure obtained with six quartz tungsten halogen and light-emitting diode curing units at different exposure times and light tip-resin composite distances. Resin composite specimens (Tetric Ceram, A3; diameter 4 mm, height 6 mm) were exposed from 0-, 3-, and 6-mm distance. The curing units (200-700 mW/cm2) were used for standard (20 and 40 s), pulse-delay mode (initial exposure of 3 s at 200 mW/cm2, followed by a resting period of 3 min and a final exposure of 10 or 30 s at 600 mW/cm2), or soft-start curing (40 s; exponential ramping). Curing depth was determined by measurement of Wallace hardness for each half millimeter starting at 0.5 mm from the top surface. For each specimen, a mean H(W) value was calculated from the H(W) values determined at the depths of 2.0 mm and less (0.5, 1.0, 1.5, and 2.0 mm, respectively). The depth of cure for each specimen was found by determining the greatest depth before an H(W) value exceeding the minimal H(W) value by 25% occurred. For all curing units, an increase in exposure time led to significantly higher depth of cure. Increasing the light tip-resin composite distance significantly reduced the depth of cure. With a light tip-resin composite distance of 6 mm, median values of depth of cure varied between 2.0 and 3.5 mm following a 20-s (or 3+10 s) exposure and between 3.0 and 4.5 mm following a 40-s (or 3+30 s) exposure. The composite situated above the depth of cure value cured equally well with all curing units. At both exposure times, Luxomax resulted in the significantly lowest depth of cure, and Astralis 7 yielded significantly higher depth. At both exposure times, a significant linear correlation was found between the determined power densities of the curing units and the pooled depth of cure values obtained. It seems that for the resin composite tested, the recommended exposure time of 40 s per 2-mm increment may be reduced to 20 s, or that increments may be increased from 2 to 3.5 mm. It may be that the absolute values of depth of cure found are material specific, but we believe that the relationships found between curing units, between exposure times, and between light guide distances are universal.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15815922     DOI: 10.1007/s00784-005-0312-9

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  35 in total

1.  Novel approach to measure composite conversion kinetics during exposure with stepped or continuous light-curing.

Authors:  F A Rueggeberg; W F Caughman; D C Chan
Journal:  J Esthet Dent       Date:  1999

2.  Guidance of shrinkage vectors vs irradiation at reduced intensity for improving marginal seal of class V resin-based composite restorations in vitro.

Authors:  N Hofmann; O Hiltl; B Hugo; B Klaiber
Journal:  Oper Dent       Date:  2002 Sep-Oct       Impact factor: 2.440

3.  Composite conversion and temperature rise using a conventional, plasma arc, and an experimental blue LED curing unit.

Authors:  Z Tarle; A Meniga; A Knezević; J Sutalo; M Ristić; G Pichler
Journal:  J Oral Rehabil       Date:  2002-07       Impact factor: 3.837

4.  Correlation between hardness and degree of conversion during the setting reaction of unfilled dental restorative resins.

Authors:  J L Ferracane
Journal:  Dent Mater       Date:  1985-02       Impact factor: 5.304

Review 5.  Clinical guidelines for photocuring restorative resins.

Authors:  W F Caughman; F A Rueggeberg; J W Curtis
Journal:  J Am Dent Assoc       Date:  1995-09       Impact factor: 3.634

6.  Depth of cure of radiation-activated materials--effect of mould material and cavity size.

Authors:  E Harrington; H J Wilson
Journal:  J Dent       Date:  1993-10       Impact factor: 4.379

7.  Effect of light intensity and exposure duration on cure of resin composite.

Authors:  F A Rueggeberg; W F Caughman; J W Curtis
Journal:  Oper Dent       Date:  1994 Jan-Feb       Impact factor: 2.440

8.  Dental composite depth of cure with halogen and blue light emitting diode technology.

Authors:  R W Mills; K D Jandt; S H Ashworth
Journal:  Br Dent J       Date:  1999-04-24       Impact factor: 1.626

9.  Decrease in power output of new light-emitting diode (LED) curing devices with increasing distance to filling surface.

Authors:  Gerrit R Meyer; Claus-Peter Ernst; Brita Willershausen
Journal:  J Adhes Dent       Date:  2002       Impact factor: 2.359

10.  Polymerization depths of contemporary light-curing units using microhardness.

Authors:  F A Rueggeberg; J W Ergle; D J Mettenburg
Journal:  J Esthet Dent       Date:  2000
View more
  13 in total

1.  Evaluation of the curing depth of two translucent composite materials using a halogen and two LED curing units.

Authors:  Olga Polydorou; Alexandros Manolakis; Elmar Hellwig; Petra Hahn
Journal:  Clin Oral Investig       Date:  2007-10-25       Impact factor: 3.573

2.  Effect of three types of light-curing units on 5-year colour changes of light-cured composite.

Authors:  Onjen Tak; Subutay Han Altintas; Nilgun Ozturk; Aslihan Usumez
Journal:  Clin Oral Investig       Date:  2008-09-04       Impact factor: 3.573

3.  Depth of cure and mechanical properties of nano-hybrid resin-based composites with novel and conventional matrix formulation.

Authors:  Karina E Frauscher; Nicoleta Ilie
Journal:  Clin Oral Investig       Date:  2011-12-02       Impact factor: 3.573

4.  Effect of different polymerization methods on the cytotoxicity of dental composites.

Authors:  Nilufer Celebi Beriat; Ahmet Atila Ertan; Senay Canay; Aylin Gurpinar; Mehmet Ali Onur
Journal:  Eur J Dent       Date:  2010-07

5.  Post-curing conversion kinetics as functions of the irradiation time and increment thickness.

Authors:  Nicola Scotti; Alberto Venturello; Francesco Andrea Coero Borga; Damiano Pasqualini; Davide Salvatore Paolino; Francesco Geobaldo; Elio Berutti
Journal:  J Appl Oral Sci       Date:  2013 Mar-Apr       Impact factor: 2.698

6.  Effects of High-Energy Curing Lights on Time-Dependent Temperature Changes of Pulp Space During Orthodontic Bonding.

Authors:  Nisa Gül Amuk; Gökmen Kurt; Özgür Er; Gülşen Çakmak; Veysel Aslantaş
Journal:  Turk J Orthod       Date:  2019-03-01

7.  Curing efficacy of light emitting diodes of dental curing units.

Authors:  Seyed Mostafa Mousavinasab; Ian Meyers
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2009-03-16

8.  Distance and protective barrier effects on the composite resin degree of conversion.

Authors:  Margareth Coutinho; Natália Carvalho Trevizam; Renata Nakase Takayassu; Ariene Arcas Leme; Giulliana Panfiglio Soares
Journal:  Contemp Clin Dent       Date:  2013-04

9.  Comparative depth of cure among two light-cured core build-up composites by surface vickers hardness.

Authors:  Mr Rouhollahi; M Mohammadibasir; Sh Talim
Journal:  J Dent (Tehran)       Date:  2012-09-30

10.  Effect of photoinitiator concentration on marginal and internal adaptation of experimental composite blends photocured by modulated methods.

Authors:  Roberta Caroline Bruschi Alonso; Eduardo José Carvalho de Souza-Júnior; Diogo Dressano; Giovana Albamonte Spagnolo de Araújo; José Manuel Ces Rodriguez; Vinícius Di Hipólito; Camillo Anauate-Netto; Regina Maria Puppin-Rontani; Mario Alexandre Coelho Sinhoreti
Journal:  Eur J Dent       Date:  2013-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.