Literature DB >> 8505878

Radiofrequency map of an NMR coil by imaging.

S Akoka1, F Franconi, F Seguin, A Le Pape.   

Abstract

We propose a new imaging method to obtain a map of the radiofrequency (RF) field amplitude over a sample. The sequence contains three RF pulses (alpha, 2 alpha, and alpha) and produces two images by a classical spin echo and a stimulated echo. A third image is computed and gives the distribution of the flip angle alpha, and so the RF amplitude, over the sample. The accuracy of the flip angle determination is verified on an homogeneous sample and results show a good correlation between experimental and theoretical flip angles in the range of 50 degrees to 130 degrees. Experiments with a surface coil and a resonator show the method is available in an inhomogeneous RF field. Images obtained on the calf of a volunteer confirms the independence of the computed RF distribution from proton density, T1, or T2 contrast.

Entities:  

Mesh:

Year:  1993        PMID: 8505878     DOI: 10.1016/0730-725x(93)90078-r

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  39 in total

1.  Mapping of low flip angles in magnetic resonance.

Authors:  Fabien Balezeau; Pierre-Antoine Eliat; Alejandro Bordelois Cayamo; Hervé Saint-Jalmes
Journal:  Phys Med Biol       Date:  2011-09-23       Impact factor: 3.609

2.  Limitations of rapid myelin water quantification using 3D bSSFP.

Authors:  C Lenz; M Klarhöfer; K Scheffler
Journal:  MAGMA       Date:  2010-04-28       Impact factor: 2.310

3.  B1 mapping by Bloch-Siegert shift.

Authors:  Laura I Sacolick; Florian Wiesinger; Ileana Hancu; Mika W Vogel
Journal:  Magn Reson Med       Date:  2010-05       Impact factor: 4.668

4.  Measuring B1 distributions by B1 phase encoding.

Authors:  Kalina V Jordanova; Dwight G Nishimura; Adam B Kerr
Journal:  Magn Reson Med       Date:  2016-01-17       Impact factor: 4.668

5.  A simple method for mapping the B1 field distribution of linear RF coils.

Authors:  Jan Weis; Peter Andris; Ivan Frollo; Håkan Ahlström
Journal:  MAGMA       Date:  2005-12-13       Impact factor: 2.310

6.  A multichannel, real-time MRI RF power monitor for independent SAR determination.

Authors:  Abdel-Monem M El-Sharkawy; Di Qian; Paul A Bottomley; William A Edelstein
Journal:  Med Phys       Date:  2012-05       Impact factor: 4.071

7.  Rapid B1 field mapping at 3 T using the 180° signal null method with extended flip angle.

Authors:  Abinand C Rejimon; Diana Y Lee; Christopher M Bergeron; You Zhuo; Wenshu Qian; Richard G Spencer; Mustapha Bouhrara
Journal:  Magn Reson Imaging       Date:  2018-06-26       Impact factor: 2.546

8.  Three-point Dixon method with a MISSTEC sequence.

Authors:  F Lethimonnier; F Franconi; S Akoka
Journal:  MAGMA       Date:  1997-12       Impact factor: 2.310

9.  Lowering the B1 threshold for improved BEAR B1 mapping.

Authors:  Kalina V Jordanova; Dwight G Nishimura; Adam B Kerr
Journal:  Magn Reson Med       Date:  2015-04-04       Impact factor: 4.668

Review 10.  Magnetic-resonance-based electrical properties tomography: a review.

Authors:  Xiaotong Zhang; Jiaen Liu; Bin He
Journal:  IEEE Rev Biomed Eng       Date:  2014
View more