Literature DB >> 8478383

Primary total hip reconstruction with a titanium fiber-coated prosthesis inserted without cement.

J M Martell1, R H Pierson, J J Jacobs, A G Rosenberg, M Maley, J O Galante.   

Abstract

A prospective study was done of the intermediate-term clinical and radiographic results of 121 total hip arthroplasties in which a Harris-Galante porous titanium-fiber-coated prosthesis was inserted without cement in 110 patients. The average age at the time of the operation was forty-nine years (range, twenty to seventy years). The average duration of follow-up was sixty-seven months (range, fifty-five to seventy-nine months). The average preoperative Harris hip score was 55 points, and the average postoperative score was 93 points. One acetabular component was revised due to recurrent dislocation. Eleven femoral implants were unstable, and of these, four were revised. Cortical erosion was present around the distal part of the femoral stem in nine patients (8 per cent) who had stable implants, and one of these femoral implants was revised because the erosion was extensive. Survivorship analysis at five years revealed a 97 per cent chance of survival (95 per cent confidence limit, 0.937 to 1.0) of the Harris-Galante femoral-stem implant inserted without cement.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8478383     DOI: 10.2106/00004623-199304000-00010

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  34 in total

1.  The dimensional accuracy of preparation of femoral cavity in cementless total hip arthroplasty.

Authors:  Li-dong Wu; H J Hahne; J Hassenpflug
Journal:  J Zhejiang Univ Sci       Date:  2004-10

2.  Early polyethylene wear and osteolysis with ABG acetabular cups (7- to 12-year follow-up).

Authors:  Sachin Badhe; Peter Livesley
Journal:  Int Orthop       Date:  2005-11-08       Impact factor: 3.075

3.  [The femoral neck prosthesis CUT. Three- to six-year results].

Authors:  S A Ender; A Machner; G Pap; H Grasshoff; H W Neumann
Journal:  Orthopade       Date:  2006-08       Impact factor: 1.087

4.  Cementless acetabular component inserted without screws - the effect of immediate weight-bearing.

Authors:  F Y Ng; Y Zhu; K Y Chiu
Journal:  Int Orthop       Date:  2006-08-19       Impact factor: 3.075

5.  Total hip arthroplasty performed in patients with residual poliomyelitis: does it work?

Authors:  Byung-Ho Yoon; Young-Kyun Lee; Jeong Joon Yoo; Hee Joong Kim; Kyung-Hoi Koo
Journal:  Clin Orthop Relat Res       Date:  2013-11-08       Impact factor: 4.176

6.  Cementless total hip arthroplasty with AML, PCA and HGP prostheses.

Authors:  S K Hwang; J S Park
Journal:  Int Orthop       Date:  1995       Impact factor: 3.075

7.  Dual offset metaphyseal-filling stems in primary total hip arthroplasty in dysplastic hips after a minimum follow-up of ten years.

Authors:  Goksel Dikmen; Vahit Emre Ozden; Burak Beksac; Ismail Remzi Tozun
Journal:  Int Orthop       Date:  2018-09-19       Impact factor: 3.075

8.  Ceramic bearings with bilayer coating in cementless total hip arthroplasty. A safe solution. A retrospective study of one hundred and twenty six cases with more than ten years' follow-up.

Authors:  André Ferreira; Thierry Aslanian; Thibaud Dalin; Jean Picaud
Journal:  Int Orthop       Date:  2016-08-20       Impact factor: 3.075

9.  The uncemented Bicontact total hip arthroplasty in octogenarians. Medium-term results.

Authors:  N P Badhe; R C Quinnell; P W Howard
Journal:  Eur J Orthop Surg Traumatol       Date:  2002-12-18

10.  Early clinical results of a new conservative hip stem.

Authors:  Jaime J Morales de Cano; Christian Gordo; Jose M Illobre
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-02-27
View more