Abstract

OBJECTIVE: To observe the accuracy of femoral preparation and the position of the cementless prosthesis in femoral cavity, and to compare the results between the computer-assisted surgical group (CASPAR) and the conventional group.
METHODS: Ten femoral components were implanted either manually or by CASPAR in cadaver femurs. The specimens were cut to 3 mm thick slices. Microradiograms of every slice were sent to a computer for analysis with special software (IDL). The gaps and the medullary cavities between component and bone, the direct bone contact area of the implant surface, the gap width and the percentage of gap and bone contact area were measured in every slice.
RESULTS: In the proximal implant coated with HA of the CASPAR group, the average percentage of bone contact reached 93.2% (ranging from 87.6% to 99.7%); the average gap percentage was 2.9% (ranging from 0.3% to 7.8%); the maximum gap width was 0.81 mm and the average gap width was only 0.20 mm. While in the conventional group, the average percentage of bone contact reached 60.1% (ranging from 49.2% to 70.4%); the average gap percentage was 32.8% (ranging from 25.1% to 39.9%); the maximum gap width was 2.97 mm and the average gap width was only 0.77 mm. The average gap around the implant in the CASPAR group was only 9% of that in the manual group; the maximum and average gap widths were only about 26% of those in the manual group. On the other hand, the CASPAR group showed 33% tighter bone contact than the manual group.
CONCLUSION: With the use of robotics-assisted system, significant progress can be achieved for femoral preparation in total hip arthroplasty.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15362200      PMCID: PMC1388733          DOI: 10.1631/jzus.2004.1270

Source DB:  PubMed          Journal:  J Zhejiang Univ Sci        ISSN: 1009-3095


  31 in total

1.  Computer assisted implantation of the femoral stem in THA - an experimental study.

Authors:  J Jerosch; E Peuker; C von Hasselbach; A Lahmer; T Filler; U Witzel
Journal:  Int Orthop       Date:  1999       Impact factor: 3.075

2.  Stability and bone preservation in custom designed revision hip stems.

Authors:  P S Walker; S G Culligan; J Hua; S K Muirhead-Allwood; G Bentley
Journal:  Clin Orthop Relat Res       Date:  2000-04       Impact factor: 4.176

3.  Robotically-milled bone cavities: a comparison with hand-broaching in different types of cementless hip stems.

Authors:  Marc N Thomsen; Steffen J Breusch; Peter R Aldinger; Wolfgang Görtz; Andreas Lahmer; Mathias Honl; Andreas Birke; Hans Nägerl
Journal:  Acta Orthop Scand       Date:  2002-08

4.  Comparison of robotic-assisted and manual implantation of a primary total hip replacement. A prospective study.

Authors:  Matthias Honl; Oliver Dierk; Christian Gauck; Volker Carrero; Frank Lampe; Sebastian Dries; Markus Quante; Karsten Schwieger; Ekkehard Hille; Michael M Morlock
Journal:  J Bone Joint Surg Am       Date:  2003-08       Impact factor: 5.284

5.  Osteogenic phenomena across endosteal bone-implant spaces with porous surfaced intramedullary implants.

Authors:  J D Bobyn; R M Pilliar; H U Cameron; G C Weatherly
Journal:  Acta Orthop Scand       Date:  1981

6.  Influence of intraoperative femoral fractures and cerclage wiring on bone ingrowth into canine porous-coated femoral components.

Authors:  S F Schutzer; J Grady-Benson; M Jasty; D O O'Connor; C Bragdon; W H Harris
Journal:  J Arthroplasty       Date:  1995-12       Impact factor: 4.757

7.  Total hip arthroplasty in young patients. 8- to 13-year results using an uncemented stem.

Authors:  J R McLaughlin; K R Lee
Journal:  Clin Orthop Relat Res       Date:  2000-04       Impact factor: 4.176

8.  Clinical and radiographic outcomes of total hip arthroplasty with insertion of an anatomically designed femoral component without cement for the treatment of primary osteoarthritis. A study with a minimum of six years of follow-up.

Authors:  A A Ragab; M J Kraay; V M Goldberg
Journal:  J Bone Joint Surg Am       Date:  1999-02       Impact factor: 5.284

9.  Femoral fracture risk in hip arthroplasty: smooth versus toothed instruments.

Authors:  Søren Kold; Olivier Mouzin; Craig Bourgeault; Kjeld Søballe; Joan E Bechtold
Journal:  Clin Orthop Relat Res       Date:  2003-03       Impact factor: 4.176

10.  Primary stability of a robodoc implanted anatomical stem versus manual implantation.

Authors:  Michael Nogler; Anne Polikeit; Cornelius Wimmer; Andreas Brückner; Stephen J Ferguson; Martin Krismer
Journal:  Clin Biomech (Bristol, Avon)       Date:  2004-02       Impact factor: 2.063

View more
  2 in total

1.  Analysis of the release characteristics of cu-treated antimicrobial implant surfaces using atomic absorption spectrometry.

Authors:  Carmen Zietz; Andreas Fritsche; Birgit Finke; Vitezslav Stranak; Maximilian Haenle; Rainer Hippler; Wolfram Mittelmeier; Rainer Bader
Journal:  Bioinorg Chem Appl       Date:  2011-11-24       Impact factor: 7.778

2.  Current concepts in robotic total hip arthroplasty.

Authors:  Pascal Kouyoumdjian; Jad Mansour; Chahine Assi; Jacques Caton; Sebastien Lustig; Remy Coulomb
Journal:  SICOT J       Date:  2020-11-27
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.