Literature DB >> 8470014

Anterior spinal fixators. A biomechanical in vitro study.

T A Zdeblick1, K E Warden, D Zou, P C McAfee, J J Abitbol.   

Abstract

In vitro calf spine testing was performed in flexion, rotation, and axial load, using a vertebral body corpectomy and anterior iliac crest bone grafting model. Anterior spinal fixation devices then were sequentially tested, and axial stiffness, torsional stiffness, and flexural strain determined. The constructs tested were the Contoured Anterior Spinal Plate (CASP), the Kaneda device, the Kostuik-Harrington device (KH), and the Texas Scottish Rite Hospital (TSRH) vertebral body screw construct. In torsion, the Kaneda device returned spinal stability to that of the intact spine. The Kostuik-Harrington device was unstable in torsion. In axial loading and flexion, the Kaneda device and the TSRH construct proved the most stiff, with the KH and CASP systems significantly lower in stiffness. The authors believe that the Kaneda device and the TSRH vertebral body screw construct are effective in restoring acute stability to the lumbar spine after corpectomy.

Entities:  

Mesh:

Year:  1993        PMID: 8470014

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  10 in total

1.  Thoracolumbar fracture stabilization: comparative biomechanical evaluation of a new video-assisted implantable system.

Authors:  M Schultheiss; E Hartwig; L Kinzl; L Claes; H-J Wilke
Journal:  Eur Spine J       Date:  2003-11-22       Impact factor: 3.134

2.  Influence of screw-cement enhancement on the stability of anterior thoracolumbar fracture stabilization with circumferential instability.

Authors:  Markus Schultheiss; Erich Hartwig; Lutz Claes; Lothar Kinzl; Hans-Joachim Wilke
Journal:  Eur Spine J       Date:  2004-06-22       Impact factor: 3.134

3.  A history of spine biomechanics. Focus on 20th century progress.

Authors:  T R Oxland
Journal:  Unfallchirurg       Date:  2015-12       Impact factor: 1.000

4.  Primary stability of anterior lumbar stabilization: interdependence of implant type and endplate retention or removal.

Authors:  Christian H Flamme; Nadine von der Heide; Caroline Heymann; Christof Hurschler
Journal:  Eur Spine J       Date:  2005-08-10       Impact factor: 3.134

5.  Pullout strength of anterior spinal instrumentation: a product comparison of seven screws in calf vertebral bodies.

Authors:  Konrad Seller; Dieter Wahl; Alexander Wild; Rüdiger Krauspe; Erich Schneider; Berend Linke
Journal:  Eur Spine J       Date:  2007-02-02       Impact factor: 3.134

6.  Load-displacement properties of the thoracolumbar calf spine: experimental results and comparison to known human data.

Authors:  H J Wilke; S T Krischak; K H Wenger; L E Claes
Journal:  Eur Spine J       Date:  1997       Impact factor: 3.134

7.  Biomechanical in vitro comparison of different mono- and bisegmental anterior procedures with regard to the strategy for fracture stabilisation using minimally invasive techniques.

Authors:  Markus Schultheiss; Erich Hartwig; Michael Sarkar; Lothar Kinzl; Lutz Claes; Hans-Joachim Wilke
Journal:  Eur Spine J       Date:  2005-02-04       Impact factor: 3.134

8.  Mechanical Analysis of Posterior Pedicle Screw System Placement and Internal Fixation in the Treatment of Lumbar Fractures.

Authors:  Shengkai Mu; Jingxu Wang; Shuyi Gong
Journal:  Comput Math Methods Med       Date:  2022-04-11       Impact factor: 2.809

9.  CDH: preliminary report on a new anterior spinal instrumentation.

Authors:  A Hopf; P Eysel; J Dubousset
Journal:  Eur Spine J       Date:  1995       Impact factor: 3.134

10.  Efficacy of Pedicle Screw Fixation in Unstable Upper and Middle Thoracic Spine Fractures.

Authors:  Amir Abbas Ghasemi; Soudabeh Ashoori
Journal:  Trauma Mon       Date:  2016-02-06
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.