Literature DB >> 8462614

Determination of the technetium-99m mercaptoacetyltriglycine plasma clearance in children by means of a single blood sample: a multicentre study. The Paediatric Task Group of the EANM.

A Piepsz1, I Gordon, K Hahn, J Kolinska, J Kotzerke, R Sixt.   

Abstract

A multicentre European study was undertaken in order to determine a reasonable algorithm allowing the determination of overall technetium-99m mercaptoacetyltriglycine clearance using a single blood sample. Employing multiple blood sample clearance as a reference method, it was shown that an acceptable estimation of the MAG3 renal clearance could be obtained using a blood sample taken at any time between 30 and 40 min after tracer injection. After correction for body surface area, comparison of clearance determined using (a) the single blood sample and (b) the multiple blood samples provided a coefficient of correlation of 0.949 and an SEE of 27 ml/min. This algorithm is valid for clearance values higher than 100 ml/min/1.73 m2 and for children older than 1 year of age.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8462614     DOI: 10.1007/bf00170006

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  10 in total

1.  Volumes of distribution and clearances of intravenously injected creatinine in the dog.

Authors:  L A SAPIRSTEIN; D G VIDT; M J MANDEL; G HANUSEK
Journal:  Am J Physiol       Date:  1955-05

2.  Effects of arterial versus venous sampling on analysis of glucose kinetics in man.

Authors:  E A McGuire; J H Helderman; J D Tobin; R Andres; M Berman
Journal:  J Appl Physiol       Date:  1976-10       Impact factor: 3.531

3.  Handling of 99mTc-MAG3 in the kidney.

Authors:  C Müller-Suur; R Müller-Suur
Journal:  Contrib Nephrol       Date:  1990       Impact factor: 1.580

4.  Single-sample method for the estimation of glomerular filtration rate in children.

Authors:  W N Tauxe; A Bagchi; P G Tepe; P R Krishnaiah
Journal:  J Nucl Med       Date:  1987-03       Impact factor: 10.057

5.  Measurement of glomerular filtration rate: single injection plasma clearance method without urine collection.

Authors:  C D Russell; P G Bischoff; F N Kontzen; K L Rowell; M V Yester; L K Lloyd; W N Tauxe; E V Dubovsky
Journal:  J Nucl Med       Date:  1985-11       Impact factor: 10.057

6.  51Cr-EDTA clearance determined by one plasma sample in children.

Authors:  S Groth; M Aasted
Journal:  Clin Physiol       Date:  1984-02

7.  Estimation of technetium-99m-MAG3 plasma clearance in adults from one or two blood samples.

Authors:  C D Russell; A Taylor; D Eshima
Journal:  J Nucl Med       Date:  1989-12       Impact factor: 10.057

8.  Determination of 99mTc-DTPA clearance by a single plasma sample method.

Authors:  A B Christensen; S Groth
Journal:  Clin Physiol       Date:  1986-12

9.  Estimation of glomerular filtration rate in infants and in children using a single-plasma sample method.

Authors:  H R Ham; A Piepsz
Journal:  J Nucl Med       Date:  1991-06       Impact factor: 10.057

10.  Technetium 99m mercaptoacetyltriglycine gamma camera clearance calculations: methodological problems.

Authors:  M Tondeur; A Piepsz; A Dobbeleir; H Ham
Journal:  Eur J Nucl Med       Date:  1991
  10 in total
  1 in total

1.  Reproducibility of technetium-99m mercaptoacetyltriglycine clearance.

Authors:  A Piepsz; M Tondeur; J Kinthaert; H R Ham
Journal:  Eur J Nucl Med       Date:  1996-02
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.