Literature DB >> 6421538

51Cr-EDTA clearance determined by one plasma sample in children.

S Groth, M Aasted.   

Abstract

51Cr-EDTA clearance was determined in 50 children from the activity in one plasma sample by means of two methods. The calculation of 51Cr-EDTA clearance by method I (ClI) was based on a transformation of the biexponential time-activity curve into a monoexponential with identical area below the time-activity curve. The calculation of 51Cr-EDTA clearance by method II (ClII) was based on a close relation between 51Cr-EDTA clearance and the reciprocal apparent volume of distribution normalized with respect to body surface area. It was demonstrated that the two methods were closely related. To test the accuracy of the two methods, the results of ClI and ClII were compared to 51Cr-EDTA clearance calculated by means of a standard, multiple plasma sample method (ClSM). The correlations between ClSM and ClI and between ClSM and ClII were almost identical (r = 0.993 and r = 0.992). The accuracy of 51Cr-EDTA clearance calculated as ClI and ClII did not differ significantly from each other.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6421538     DOI: 10.1111/j.1475-097x.1984.tb00646.x

Source DB:  PubMed          Journal:  Clin Physiol        ISSN: 0144-5979


  5 in total

Review 1.  Measuring glomerular filtration rate in children; can cystatin C replace established methods? A review.

Authors:  Trine Borup Andersen; Anni Eskild-Jensen; Jørgen Frøkiaer; Jens Brøchner-Mortensen
Journal:  Pediatr Nephrol       Date:  2008-10-07       Impact factor: 3.714

2.  Determination of the technetium-99m mercaptoacetyltriglycine plasma clearance in children by means of a single blood sample: a multicentre study. The Paediatric Task Group of the EANM.

Authors:  A Piepsz; I Gordon; K Hahn; J Kolinska; J Kotzerke; R Sixt
Journal:  Eur J Nucl Med       Date:  1993-03

3.  Iohexol plasma clearance in children: validation of multiple formulas and single-point sampling times.

Authors:  Camilla Tøndel; Cathrin Lytomt Salvador; Karl Ove Hufthammer; Bjørn Bolann; Damien Brackman; Anna Bjerre; Einar Svarstad; Atle Brun
Journal:  Pediatr Nephrol       Date:  2017-11-13       Impact factor: 3.714

4.  A Comparison of the Accuracy of Different Single Plasma Sample Methods for Measuring Glomerular Filtration Rate Using 51Cr-EDTA in Children.

Authors:  Sejin Ha; Jong Jin Lee
Journal:  Nucl Med Mol Imaging       Date:  2018-06-28

5.  Iohexol plasma clearance for measuring glomerular filtration rate in clinical practice and research: a review. Part 1: How to measure glomerular filtration rate with iohexol?

Authors:  Pierre Delanaye; Natalie Ebert; Toralf Melsom; Flavio Gaspari; Christophe Mariat; Etienne Cavalier; Jonas Björk; Anders Christensson; Ulf Nyman; Esteban Porrini; Giuseppe Remuzzi; Piero Ruggenenti; Elke Schaeffner; Inga Soveri; Gunnar Sterner; Bjørn Odvar Eriksen; Sten-Erik Bäck
Journal:  Clin Kidney J       Date:  2016-08-23
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.