Literature DB >> 3539465

Determination of 99mTc-DTPA clearance by a single plasma sample method.

A B Christensen, S Groth.   

Abstract

To derive a formula for determination of 99mTc-DTPA clearance (Cl) from the radioactivity in a single plasma sample, the relation Cl = ECV/t was used, where ECV is the extracellular volume and t is the mean transit time of the tracer in the organism. By studying 99mTc-DTPA time activity curves of 45 consecutive patients we found that ECV could be estimated from the body surface area, and that t could be calculated from the radioactivity in a single plasma sample. Cl calculated by the single sample method was almost identical to Cl calculated by a standard multiple sample method (r = 0.987). It is concluded that the single sample method is accurate and that it may prove useful as a routine method provided that the method is not used in patients with 99mTc-DTPA clearance less than 30 ml min-1, since this investigation includes only patients with Cl greater than 30 ml min-1; the method is not used for children, since the test material did not contain any children; the method is only used for plasma samples drawn at 180 less than or equal to t less than or equal to 300 min.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3539465     DOI: 10.1111/j.1475-097x.1986.tb00790.x

Source DB:  PubMed          Journal:  Clin Physiol        ISSN: 0144-5979


  13 in total

1.  A simple method of estimating glomerular filtration rate.

Authors:  W S Watson
Journal:  Eur J Nucl Med       Date:  1992

2.  Estimation of chromium-51 ethylene diamine tetra-acetic acid plasma clearance: a comparative assessment of simplified techniques.

Authors:  G Picciotto; G Cacace; P Cesana; R Mosso; R Ropolo; P G De Filippi
Journal:  Eur J Nucl Med       Date:  1992

3.  Measuring and estimating glomerular filtration rate in children.

Authors:  Hans Pottel
Journal:  Pediatr Nephrol       Date:  2016-04-26       Impact factor: 3.714

4.  Determination of the technetium-99m mercaptoacetyltriglycine plasma clearance in children by means of a single blood sample: a multicentre study. The Paediatric Task Group of the EANM.

Authors:  A Piepsz; I Gordon; K Hahn; J Kolinska; J Kotzerke; R Sixt
Journal:  Eur J Nucl Med       Date:  1993-03

5.  Identification of asymptomatic type 2 diabetes mellitus patients with a low, intermediate and high risk of ischaemic heart disease: is there an algorithm?

Authors:  M K Poulsen; J E Henriksen; W Vach; J Dahl; J E Møller; A Johansen; O Gerke; T Haghfelt; P F Høilund-Carlsen; H Beck-Nielsen
Journal:  Diabetologia       Date:  2010-01-14       Impact factor: 10.122

6.  Body fluid regulation via chronic inhibition of sodium-glucose cotransporter-2 in patients with heart failure: a post hoc analysis of the CANDLE trial.

Authors:  Shinya Fujiki; Atsushi Tanaka; Takumi Imai; Michio Shimabukuro; Hiroki Uehara; Ikuko Nakamura; Kazuo Matsunaga; Makoto Suzuki; Takeshi Kashimura; Tohru Minamino; Takayuki Inomata; Koichi Node
Journal:  Clin Res Cardiol       Date:  2022-06-22       Impact factor: 5.460

7.  Estimation of technetium 99m mercaptoacetyltriglycine plasma clearance by use of one single plasma sample.

Authors:  R Müller-Suur; G Magnusson; I Bois-Svensson; B Jansson
Journal:  Eur J Nucl Med       Date:  1991

8.  A Comprehensive Software and Database Management System for Glomerular Filtration Rate Estimation by Radionuclide Plasma Sampling and Serum Creatinine Methods.

Authors:  Ashish Kumar Jha
Journal:  World J Nucl Med       Date:  2015 May-Aug

9.  Comparison of glomerular filtration rate measured by plasma sample technique, Cockroft Gault method and Gates' method in voluntary kidney donors and renal transplant recipients.

Authors:  Julie Hephzibah; Nylla Shanthly; Regi Oommen
Journal:  Indian J Nucl Med       Date:  2013-07

10.  A Comparison of the Accuracy of Different Single Plasma Sample Methods for Measuring Glomerular Filtration Rate Using 51Cr-EDTA in Children.

Authors:  Sejin Ha; Jong Jin Lee
Journal:  Nucl Med Mol Imaging       Date:  2018-06-28
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.