Literature DB >> 1828421

Technetium 99m mercaptoacetyltriglycine gamma camera clearance calculations: methodological problems.

M Tondeur1, A Piepsz, A Dobbeleir, H Ham.   

Abstract

Major sources of errors in the gamma-camera methods for the calculation of renal clearance are the accuracy of background correction for obtaining the true renal time-activity curve and the validity of the externally recorded pre-cordial activity as an estimate of the plasmatic time-activity curve. With technetium 99m mercaptoacetyltriglycine (99mTc-MAG3), because of its high protein plasma binding, one could expect minimal extravascular diffusion and hence a more accurate externally detected plasmatic curve. The high extraction rate should reduce the influence of the background, but, on the other hand, the effect of hepatobiliary excretion on the calculation of renal clearance might be significant. Our results suggest that the hepatobiliary excretion of 99mTc-MAG3 does not influence the gamma-camera renal clearance determination, even in patients with low renal function. However, the pre-cordial curve does not reflect accurately the plasmatic disappearance curve; its calibration with a single plasma sample taken at the 20th min is responsible for significant errors, probably because of an unfavourable ratio between the intravascular and extravascular activities at the 20th min.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1828421     DOI: 10.1007/bf00950751

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  12 in total

1.  Technetium-99m MAG3 kit formulation: preliminary results in normal volunteers and patients with renal failure.

Authors:  A Taylor; D Eshima; P E Christian; W W Wooten; L Hansen; K McElvany
Journal:  J Nucl Med       Date:  1988-05       Impact factor: 10.057

2.  Technetium-99m MAG3, a comparison with iodine-123 and iodine-131 orthoiodohippurate, in patients with renal disorders.

Authors:  R A Jafri; K E Britton; C C Nimmon; K Solanki; A Al-Nahhas; J Bomanji; J Fettich; L A Hawkins
Journal:  J Nucl Med       Date:  1988-02       Impact factor: 10.057

3.  Estimating the plasma time-activity curve during radionuclide renography.

Authors:  A Kuruc; S T Treves; P R Rosen; D Greenberg
Journal:  J Nucl Med       Date:  1987-08       Impact factor: 10.057

4.  Quantitation of renal function with technetium-99m MAG3.

Authors:  C D Russell; B L Thorstad; M V Yester; M Stutzman; E V Dubovsky
Journal:  J Nucl Med       Date:  1988-12       Impact factor: 10.057

5.  A comprehensive analysis of renal DTPA studies. I. Theory and normal values.

Authors:  M D Rutland
Journal:  Nucl Med Commun       Date:  1985-01       Impact factor: 1.690

6.  Effect of background correction on separate technetium-99m-DTPA renal clearance.

Authors:  A Piepsz; A Dobbeleir; H R Ham
Journal:  J Nucl Med       Date:  1990-04       Impact factor: 10.057

7.  Synthesis and biological evaluation of technetium-99m MAG3 as a hippuran replacement.

Authors:  A R Fritzberg; S Kasina; D Eshima; D L Johnson
Journal:  J Nucl Med       Date:  1986-01       Impact factor: 10.057

8.  Evaluation of 99Tcm mercaptoacetyltriglycine for the detection and localization of gastrointestinal bleeding in an experimental animal model.

Authors:  A Owunwanne; I al-Wafai; S Vallgren; S Sadek; H M Abdel-Dayem; T Yakoub; M Awdeh
Journal:  Nucl Med Commun       Date:  1988-05       Impact factor: 1.690

9.  Evaluation of Tc-99m mercaptoacetyltriglycine in patients with impaired renal function.

Authors:  A Taylor; D Eshima; P E Christian; W Milton
Journal:  Radiology       Date:  1987-02       Impact factor: 11.105

10.  Renal and extrarenal handling of a new imaging compound (99m-Tc-MAG-3) in the rat.

Authors:  R Müller-Suur; C Müller-Suur
Journal:  Eur J Nucl Med       Date:  1986
View more
  2 in total

Review 1.  Quantification of renal haemodynamics with radionuclides.

Authors:  A M Peters
Journal:  Eur J Nucl Med       Date:  1991

2.  Determination of the technetium-99m mercaptoacetyltriglycine plasma clearance in children by means of a single blood sample: a multicentre study. The Paediatric Task Group of the EANM.

Authors:  A Piepsz; I Gordon; K Hahn; J Kolinska; J Kotzerke; R Sixt
Journal:  Eur J Nucl Med       Date:  1993-03
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.