Literature DB >> 8448400

Accuracy of phase-contrast flow measurements in the presence of partial-volume effects.

C Tang1, D D Blatter, D L Parker.   

Abstract

The accuracy of volume flow rate measurements obtained with phase-contrast methods was assessed by means of computer simulation and in vitro experiments. Factors studied include (a) the partial-volume effect due to voxel dimensions relative to vessel dimensions and orientation and (b) intravoxel phase dispersion. It is shown that limited resolution (partial-volume effect) is the major obstacle to accurate flow measurement for both laminar and plug flow. The results show that at least 16 voxels must cover the cross section of the vessel lumen to obtain a measurement accuracy to within 10%. Measurement accuracy also greatly depends on the relative signal intensity of stationary tissue and is better for laminar flow than plug flow.

Mesh:

Year:  1993        PMID: 8448400     DOI: 10.1002/jmri.1880030213

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  60 in total

1.  Accurate measurement of pulsatile flow velocity in a small tube phantom: comparison of phase-contrast cine magnetic resonance imaging and intraluminal Doppler guidewire.

Authors:  Haruhiko Machida; Yoshiaki Komori; Eiko Ueno; Yun Shen; Masami Hirata; Shinya Kojima; Munekuni Sato; Takeshi Okazaki; Ai Masukawa; Satoru Morita; Kazufumi Suzuki
Journal:  Jpn J Radiol       Date:  2010-10-24       Impact factor: 2.374

2.  In vivo evaluation of quantitative MR angiography in a canine carotid artery stenosis model.

Authors:  M Calderon-Arnulphi; S Amin-Hanjani; A Alaraj; M Zhao; X Du; S Ruland; X J Zhou; K R Thulborn; F T Charbel
Journal:  AJNR Am J Neuroradiol       Date:  2011-08-11       Impact factor: 3.825

3.  Phase-contrast MRI and CFD modeling of apparent ³He gas flow in rat pulmonary airways.

Authors:  Kevin R Minard; Andrew P Kuprat; Senthil Kabilan; Richard E Jacob; Daniel R Einstein; James P Carson; Richard A Corley
Journal:  J Magn Reson       Date:  2012-05-23       Impact factor: 2.229

4.  Four-dimensional flow MRI for evaluation of post-stenotic turbulent flow in a phantom: comparison with flowmeter and computational fluid dynamics.

Authors:  Jihoon Kweon; Dong Hyun Yang; Guk Bae Kim; Namkug Kim; MunYoung Paek; Aurelien F Stalder; Andreas Greiser; Young-Hak Kim
Journal:  Eur Radiol       Date:  2016-01-08       Impact factor: 5.315

5.  Normal ranges and test-retest reproducibility of flow and velocity parameters in intracranial arteries measured with phase-contrast magnetic resonance imaging.

Authors:  Maria Correia de Verdier; Johan Wikström
Journal:  Neuroradiology       Date:  2016-02-16       Impact factor: 2.804

6.  Relationship between variations in the circle of Willis and flow rates in internal carotid and basilar arteries determined by means of magnetic resonance imaging with semiautomated lumen segmentation: reference data from 125 healthy volunteers.

Authors:  H Tanaka; N Fujita; T Enoki; K Matsumoto; Y Watanabe; K Murase; H Nakamura
Journal:  AJNR Am J Neuroradiol       Date:  2006-09       Impact factor: 3.825

7.  Accelerated dynamic Fourier velocity encoding by exploiting velocity-spatio-temporal correlations.

Authors:  Michael S Hansen; Christof Baltes; Jeffrey Tsao; Sebastian Kozerke; Klaas P Pruessmann; Peter Boesiger; Erik M Pedersen
Journal:  MAGMA       Date:  2004-11-09       Impact factor: 2.310

Review 8.  Applications of phase-contrast flow and velocity imaging in cardiovascular MRI.

Authors:  Peter D Gatehouse; Jennifer Keegan; Lindsey A Crowe; Sharmeen Masood; Raad H Mohiaddin; Karl-Friedrich Kreitner; David N Firmin
Journal:  Eur Radiol       Date:  2005-07-08       Impact factor: 5.315

9.  Accuracy of conventional oximetry for flow estimation in patients with superior cavopulmonary connection: a comparison with phase-contrast cardiac MRI.

Authors:  Tacy E Downing; Kevin K Whitehead; Yoav Dori; Matthew J Gillespie; Matthew A Harris; Mark A Fogel; Jonathan J Rome; Andrew C Glatz
Journal:  Circ Cardiovasc Imaging       Date:  2013-10-04       Impact factor: 7.792

10.  Characterization of volumetric flow rate waveforms at the carotid bifurcations of older adults.

Authors:  Yiemeng Hoi; Bruce A Wasserman; Yuanyuan J Xie; Samer S Najjar; Luigi Ferruci; Edward G Lakatta; Gary Gerstenblith; David A Steinman
Journal:  Physiol Meas       Date:  2010-01-20       Impact factor: 2.833

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.