Literature DB >> 22771528

Phase-contrast MRI and CFD modeling of apparent ³He gas flow in rat pulmonary airways.

Kevin R Minard1, Andrew P Kuprat, Senthil Kabilan, Richard E Jacob, Daniel R Einstein, James P Carson, Richard A Corley.   

Abstract

Phase-contrast (PC) magnetic resonance imaging (MRI) with hyperpolarized ³He is potentially useful for developing and testing patient-specific models of pulmonary airflow. One challenge, however, is that PC-MRI provides apparent values of local ³He velocity that not only depend on actual airflow but also on gas diffusion. This not only blurs laminar flow patterns in narrow airways but also introduces anomalous airflow structure that reflects gas-wall interactions. Here, both effects are predicted in a live rat using computational fluid dynamics (CFD), and for the first time, simulated patterns of apparent ³He gas velocity are compared with in vivo PC-MRI. Results show (1) that correlations (R²) between measured and simulated airflow patterns increase from 0.23 to 0.79 simply by accounting for apparent ³He transport, and (2) that remaining differences are mainly due to uncertain airway segmentation and partial volume effects stemming from relatively coarse MRI resolution. Higher-fidelity testing of pulmonary airflow predictions should therefore be possible with future imaging improvements.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22771528      PMCID: PMC3448557          DOI: 10.1016/j.jmr.2012.05.007

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  29 in total

1.  Registered (1)H and (3)He magnetic resonance microscopy of the lung.

Authors:  G A Johnson; G P Cofer; L W Hedlund; R R Maronpot; S A Suddarth
Journal:  Magn Reson Med       Date:  2001-03       Impact factor: 4.668

2.  MR phase-contrast flow measurement with limited spatial resolution in small vessels: value of model-based image analysis.

Authors:  R M Hoogeveen; C J Bakker; M A Viergever
Journal:  Magn Reson Med       Date:  1999-03       Impact factor: 4.668

3.  Diffusion in binary gas mixtures studied by NMR of hyperpolarized gases and molecular dynamics simulations.

Authors:  R H Acosta; L Agulles-Pedrós; S Komin; D Sebastiani; H W Spiess; P Blümler
Journal:  Phys Chem Chem Phys       Date:  2006-08-14       Impact factor: 3.676

Review 4.  On the asymmetry of bifurcations in the bronchial tree.

Authors:  C G Phillips; S R Kaye
Journal:  Respir Physiol       Date:  1997-01

5.  High resolution lung airway cast segmentation with proper topology suitable for computational fluid dynamic simulations.

Authors:  James P Carson; Daniel R Einstein; Kevin R Minard; Michelle V Fanucchi; Christopher D Wallis; Richard A Corley
Journal:  Comput Med Imaging Graph       Date:  2010-04-10       Impact factor: 4.790

6.  Accuracy of phase-contrast flow measurements in the presence of partial-volume effects.

Authors:  C Tang; D D Blatter; D L Parker
Journal:  J Magn Reson Imaging       Date:  1993 Mar-Apr       Impact factor: 4.813

Review 7.  The lung physiome: merging imaging-based measures with predictive computational models.

Authors:  Merryn H Tawhai; Eric A Hoffman; Ching-Long Lin
Journal:  Wiley Interdiscip Rev Syst Biol Med       Date:  2009 Jul-Aug

8.  Effects of temperature and composition on the viscosity of respiratory gases.

Authors:  M J Turner; I M MacLeod; A D Rothberg
Journal:  J Appl Physiol (1985)       Date:  1989-07

9.  MR imaging of apparent 3He gas transport in narrow pipes and rodent airways.

Authors:  Kevin R Minard; Richard E Jacob; Gernot Laicher; Daniel R Einstein; Andrew P Kuprat; Richard A Corley
Journal:  J Magn Reson       Date:  2008-07-13       Impact factor: 2.229

10.  In vitro validation of computational fluid dynamic simulation in human proximal airways with hyperpolarized 3He magnetic resonance phase-contrast velocimetry.

Authors:  Ludovic de Rochefort; Laurence Vial; Redouane Fodil; Xavier Maître; Bruno Louis; Daniel Isabey; Georges Caillibotte; Marc Thiriet; Jacques Bittoun; Emmanuel Durand; Gabriela Sbirlea-Apiou
Journal:  J Appl Physiol (1985)       Date:  2007-02-08
View more
  12 in total

1.  Observation of cardiogenic flow oscillations in healthy subjects with hyperpolarized 3He MRI.

Authors:  Guilhem J Collier; Helen Marshall; Madhwesha Rao; Neil J Stewart; David Capener; Jim M Wild
Journal:  J Appl Physiol (1985)       Date:  2015-09-03

Review 2.  Dosimetry of inhaled elongate mineral particles in the respiratory tract: The impact of shape factor.

Authors:  Bahman Asgharian; T Price Owen; Eileen D Kuempel; Annie M Jarabek
Journal:  Toxicol Appl Pharmacol       Date:  2018-05-05       Impact factor: 4.219

Review 3.  Using imaging as a biomarker for asthma.

Authors:  Abhaya Trivedi; Chase Hall; Eric A Hoffman; Jason C Woods; David S Gierada; Mario Castro
Journal:  J Allergy Clin Immunol       Date:  2017-01       Impact factor: 10.793

4.  Distribution of aerosolized particles in healthy and emphysematous rat lungs: comparison between experimental and numerical studies.

Authors:  Jessica M Oakes; Alison L Marsden; Céline Grandmont; Chantal Darquenne; Irene E Vignon-Clementel
Journal:  J Biomech       Date:  2015-01-22       Impact factor: 2.712

5.  Comparative Risks of Aldehyde Constituents in Cigarette Smoke Using Transient Computational Fluid Dynamics/Physiologically Based Pharmacokinetic Models of the Rat and Human Respiratory Tracts.

Authors:  Richard A Corley; Senthil Kabilan; Andrew P Kuprat; James P Carson; Richard E Jacob; Kevin R Minard; Justin G Teeguarden; Charles Timchalk; Sudhakar Pipavath; Robb Glenny; Daniel R Einstein
Journal:  Toxicol Sci       Date:  2015-04-08       Impact factor: 4.849

6.  Airflow and particle deposition simulations in health and emphysema: from in vivo to in silico animal experiments.

Authors:  Jessica M Oakes; Alison L Marsden; Celine Grandmont; Shawn C Shadden; Chantal Darquenne; Irene E Vignon-Clementel
Journal:  Ann Biomed Eng       Date:  2013-12-07       Impact factor: 3.934

7.  Comparison of CT-derived ventilation maps with deposition patterns of inhaled microspheres in rats.

Authors:  Richard E Jacob; Wayne J Lamm; Daniel R Einstein; Melissa A Krueger; Robb W Glenny; Richard A Corley
Journal:  Exp Lung Res       Date:  2014-12-16       Impact factor: 2.459

Review 8.  Perspectives of hyperpolarized noble gas MRI beyond 3He.

Authors:  David M L Lilburn; Galina E Pavlovskaya; Thomas Meersmann
Journal:  J Magn Reson       Date:  2012-12-08       Impact factor: 2.229

9.  Dynamic multiscale boundary conditions for 4D CT of healthy and emphysematous rats.

Authors:  Richard E Jacob; James P Carson; Mathew Thomas; Daniel R Einstein
Journal:  PLoS One       Date:  2013-06-14       Impact factor: 3.240

10.  Automated measurement of heterogeneity in CT images of healthy and diseased rat lungs using variogram analysis of an octree decomposition.

Authors:  Richard E Jacob; James P Carson
Journal:  BMC Med Imaging       Date:  2014-01-06       Impact factor: 1.930

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.