Literature DB >> 8444949

Hydroxyapatite coating converts fibrous tissue to bone around loaded implants.

K Søballe1, E S Hansen, H Brockstedt-Rasmussen, C Bünger.   

Abstract

In previous studies, we have demonstrated a fibrocartilaginous membrane around hydroxyapatite-coated implants subjected to micromovement in contrast to the fibrous connective tissue which predominates around similarly loaded titanium alloy implants. In the present study, in mature dogs, we investigated the effect of immobilising titanium (Ti)- or hydroxyapatite (HA)-coated implants already surrounded by a movement-induced fibrous membrane and compared the results with those of similar implants in which continuous micromovement was allowed to continue. The implants were inserted in the medial femoral condyles of 14 dogs and subjected to 150 microns movements during each gait cycle. After four weeks (when a fibrous membrane had developed), half the implants were immobilised to prevent further micromovement. The dogs were killed at 16 weeks and the results were evaluated by push-out tests and histological analysis. The continuously loaded Ti-coated implants were surrounded by a fibrous membrane, whereas bridges of new bone anchored the HA-coated implants. The immobilised implants were surrounded by bone irrespective of the type of coating. Push-out tests of the continuously loaded implants showed better fixation of those with HA coating (p < 0.001). The immobilised Ti-coated implants had four times stronger fixation than did continuously loaded Ti-coated implants (p < 0.01) but there was no equivalent difference between the two groups of HA-coated implants. The amount of bone ingrowth was greater into immobilised HA-coated implants than into immobilised Ti-coated implants (p < 0.01). Two-thirds of the HA coating had been resorbed after 16 weeks of implantation, but 25% of this resorbed HA had been replaced by bone.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8444949

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  45 in total

1.  Osseointegration in hip prostheses: experimental study in sheep.

Authors:  C Doria; V De Santis; G Falcone; L Proietti; E De Santis
Journal:  Int Orthop       Date:  2003-06-17       Impact factor: 3.075

2.  Effect of the initial implant fitting on the predicted secondary stability of a cementless stem.

Authors:  M Viceconti; A Pancanti; M Dotti; F Traina; L Cristofolini
Journal:  Med Biol Eng Comput       Date:  2004-03       Impact factor: 2.602

3.  A biomechanical regulatory model for periprosthetic fibrous-tissue differentiation.

Authors:  R Huiskes; W D Van Driel; P J Prendergast; K Søballe
Journal:  J Mater Sci Mater Med       Date:  1997-12       Impact factor: 3.896

4.  Cancellous bone osseointegration is enhanced by in vivo loading.

Authors:  Bettina M Willie; Xu Yang; Natalie H Kelly; Jane Han; Turya Nair; Timothy M Wright; Marjolein C H van der Meulen; Mathias P G Bostrom
Journal:  Tissue Eng Part C Methods       Date:  2010-05-22       Impact factor: 3.056

5.  Numerical model to predict the long-term mechanical stability of cementless orthopaedic implants.

Authors:  M Viceconti; S Ricci; A Pancanti; A Cappello
Journal:  Med Biol Eng Comput       Date:  2004-11       Impact factor: 2.602

6.  No effect of platelet-rich plasma with frozen or processed bone allograft around noncemented implants.

Authors:  T B Jensen; O Rahbek; S Overgaard; K Søballe
Journal:  Int Orthop       Date:  2005-02-01       Impact factor: 3.075

7.  Clinical and radiological outcome of hydroxyapatite-coated femoral stem in revision hip arthroplasty.

Authors:  T Gosens; E J van Langelaan
Journal:  Int Orthop       Date:  2005-05-18       Impact factor: 3.075

8.  Osteophilic multilayer coatings for accelerated bone tissue growth.

Authors:  Nisarg J Shah; Jinkee Hong; Md Nasim Hyder; Paula T Hammond
Journal:  Adv Mater       Date:  2012-02-07       Impact factor: 30.849

Review 9.  Role of primary stability for successful osseointegration of dental implants: Factors of influence and evaluation.

Authors:  Fawad Javed; Hameeda Bashir Ahmed; Roberto Crespi; Georgios E Romanos
Journal:  Interv Med Appl Sci       Date:  2013-12-20

10.  Fixation of hydroxyapatite-coated revision implants is improved by the surgical technique of cracking the sclerotic bone rim.

Authors:  Brian Elmengaard; Joan E Bechtold; Xinqian Chen; Kjeld Søballe
Journal:  J Orthop Res       Date:  2009-08       Impact factor: 3.494

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.