Literature DB >> 8444946

In vivo wear of polyethylene acetabular components.

J M Kabo1, J S Gebhard, G Loren, H C Amstutz.   

Abstract

Polyethylene acetabular cups retrieved at revision surgery were measured by a shadowgraph technique to determine linear wear, and the values were compared with those obtained from radiographs. There was a close correlation between them, although the radiographic measurements slightly underestimated the true wear. Average linear wear rates for surface-replacement components were much greater than those for conventional prostheses with femoral heads up to 32 mm in diameter. Volumetric wear, calculated using a new formula, was found to be less than previously reported in vivo, and similar in magnitude to the results of experimental wear tests in vitro. The volumetric wear rates were greatest for the surface-replacement components and, for conventional components, were found to increase in a linear manner with component diameter.

Entities:  

Mesh:

Year:  1993        PMID: 8444946

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  25 in total

1.  Retrieved total hip prostheses. Part I: the effects of cup thickness, head sizes and fusion defects on wear.

Authors:  H Oonishi; E Tsuji; Y Y Kim
Journal:  J Mater Sci Mater Med       Date:  1998-07       Impact factor: 3.896

2.  A combined XPS-SEM/EDX investigation on explanted UHMW polyethylene acetabular cups: possible role of silicon traces in the wear debris.

Authors:  E De Giglio; A Motta; L Quagliarella; L Sabbatini; G Solarino; P G Zambonin
Journal:  J Mater Sci Mater Med       Date:  2001-01       Impact factor: 3.896

3.  Constrained cups appear incapable of meeting the demands of revision THA.

Authors:  Philip C Noble; Salim K Durrani; Molly M Usrey; Kenneth B Mathis; Nikolaos V Bardakos
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

4.  Wear patterns of, and wear volume formulae for, cylindrically elongated acetabular cup liners.

Authors:  James Shih-Shyn Wu; Shu-Ling Hsu; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2010-04-28       Impact factor: 2.602

5.  The first 50 years of total hip arthroplasty: lessons learned.

Authors:  William H Harris
Journal:  Clin Orthop Relat Res       Date:  2008-11-04       Impact factor: 4.176

6.  Evaluating the accuracy of wear formulae for acetabular cup liners.

Authors:  James Shih-Shyn Wu; Shu-Ling Hsu; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2009-10-10       Impact factor: 2.602

7.  In vivo wear of a squeaky alumina-on-alumina hip prosthesis: a case report.

Authors:  Michel P Laurent; Robin Pourzal; Alfons Fischer; Kim C Bertin; Joshua J Jacobs; Markus A Wimmer
Journal:  J Bone Joint Surg Am       Date:  2011-04-06       Impact factor: 5.284

8.  Ceramic-on-ceramic bearing decreases the cumulative long-term risk of dislocation.

Authors:  Philippe Hernigou; Yasuhiro Homma; Olivier Pidet; Isaac Guissou; Jacques Hernigou
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

9.  Histological features of pseudotumor-like tissues from metal-on-metal hips.

Authors:  Pat Campbell; Edward Ebramzadeh; Scott Nelson; Karren Takamura; Koen De Smet; Harlan C Amstutz
Journal:  Clin Orthop Relat Res       Date:  2010-09       Impact factor: 4.176

10.  Ceramic-ceramic bearing decreases osteolysis: a 20-year study versus ceramic-polyethylene on the contralateral hip.

Authors:  Philippe Hernigou; Sebastien Zilber; Paolo Filippini; Alexandre Poignard
Journal:  Clin Orthop Relat Res       Date:  2009-03-13       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.