A combined XPS-SEM/EDX investigation on explanted UHMW polyethylene acetabular cups: possible role of silicon traces in the wear debris.

E De Giglio1, A Motta, L Quagliarella, L Sabbatini, G Solarino, P G Zambonin.   

Abstract

An investigation was started aimed at a better understanding of the complex phenomena leading to chemical degradation and morphological deterioration of UHMW polyethylene cups in total hip prostheses. Analysis was performed on retrieved implants which needed revision due to inflammation and pain problems. Preliminary results obtained by parallel XPS and SEM/EDX experiments gave evidence, for the first time, that silicon traces are involved in the process of particle formation and segregation onto the surface of the cups. The extent of modification of the surface chemical composition of cups and the process of particle segregation seem to be correlated to both the implant time and to some particular features of patient (age, activity, style of life, etc.). Investigation on a large number of samples is in progress in order to test this hypothesis. The results obtained so far confirmed the potential of surface spectroscopies (XPS) in biomaterial investigations. Copyright 2001 Kluwer Academic Publishers

Entities:  

Year:  2001        PMID: 15348373     DOI: 10.1023/a:1013802716574

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  13 in total

1.  Studies of the mechanism by which the mechanical failure of polymethylmethacrylate leads to bone resorption.

Authors:  S M Horowitz; S B Doty; J M Lane; A H Burstein
Journal:  J Bone Joint Surg Am       Date:  1993-06       Impact factor: 5.284

2.  The problem in total joint arthroplasty: aseptic loosening.

Authors:  S R Goldring; C R Clark; T M Wright
Journal:  J Bone Joint Surg Am       Date:  1993-06       Impact factor: 5.284

3.  Tissue changes around loose prostheses. A canine model to investigate the effects of an antiinflammatory agent.

Authors:  M Spector; S Shortkroff; H P Hsu; N Lane; C B Sledge; T S Thornhill
Journal:  Clin Orthop Relat Res       Date:  1990-12       Impact factor: 4.176

4.  Ultra-high molecular weight polyethylene wear debris generated in vivo and in laboratory tests; the influence of counterface roughness.

Authors:  J L Hailey; E Ingham; M Stone; B M Wroblewski; J Fisher
Journal:  Proc Inst Mech Eng H       Date:  1996       Impact factor: 1.617

5.  The anthropometric total hip femoral prosthesis. Preliminary clinical and roentgenographic findings of exact-fit cementless application.

Authors:  H C Amstutz; S Nasser; R C More; J M Kabo
Journal:  Clin Orthop Relat Res       Date:  1989-05       Impact factor: 4.176

6.  Failure of a polyethylene total knee component presenting as a thigh mass. Report of a rare complication of total knee arthroplasty.

Authors:  D V Chavda; K L Garvin
Journal:  Clin Orthop Relat Res       Date:  1994-06       Impact factor: 4.176

7.  Polyethylene wear in total hip arthroplasty in patient-matched groups. A comparison of stainless steel, cobalt chrome, and titanium-bearing surfaces.

Authors:  A B Bankston; P M Faris; E M Keating; M A Ritter
Journal:  J Arthroplasty       Date:  1993-06       Impact factor: 4.757

8.  Wear of polyethylene acetabular cups against alumina femoral heads. 5 prostheses compared in a hip simulator for 35 million walking cycles.

Authors:  V O Saikko
Journal:  Acta Orthop Scand       Date:  1993-10

9.  Failure of the Ring polyethylene uncemented acetabular cup.

Authors:  G D Harper; T Bull; A G Cobb; G Bentley
Journal:  J Bone Joint Surg Br       Date:  1995-07

10.  In vivo wear of polyethylene acetabular components.

Authors:  J M Kabo; J S Gebhard; G Loren; H C Amstutz
Journal:  J Bone Joint Surg Br       Date:  1993-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.