Polyethylene wear in cemented metal-backed acetabular cups.

H E Cates1, P M Faris, E M Keating, M A Ritter.   

Abstract

We examined radiographic polyethylene wear in 233 cemented total hip arthroplasties (201 patients) with either a metal-backed or a non-metal-backed acetabular cup. All patients had identical cemented one-piece titanium femoral stems with a femoral head diameter of 28 mm. The mean linear wear rate was 0.11 mm/yr in metal-backed sockets and 0.08 mm/yr in non-metal-backed sockets (p = 0.0002). The mean volumetric wear rate was 66.2 mm3/yr in the metal-backed sockets and 48.2 mm3/yr in the polyethylene sockets (p = 0.0002). The addition of metal backing to a cemented acetabular cup therefore resulted in a 37% increase in mean polyethylene wear rates which may partially explain the higher failure rate of cemented metal-backed cups. Linear regression analysis also implicated increased follow-up time (log), gross acetabular migration, metal backing and male gender in increasing polyethylene wear. We advocate the use of an all-polyethylene cup in cemented total hip arthroplasty. The increased polyethylene wear must also cause concern about the wear rate of uncemented metal-backed acetabular sockets.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8444945

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  5 in total

1.  Constrained cups appear incapable of meeting the demands of revision THA.

Authors:  Philip C Noble; Salim K Durrani; Molly M Usrey; Kenneth B Mathis; Nikolaos V Bardakos
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

2.  The use of a cemented dual mobility socket to treat recurrent dislocation.

Authors:  Moussa Hamadouche; David J Biau; Denis Huten; Thierry Musset; François Gaucher
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

3.  THA with highly cross-linked polyethylene in patients 50 years or younger.

Authors:  Derek S Shia; John C Clohisy; Mark F Schinsky; John M Martell; William J Maloney
Journal:  Clin Orthop Relat Res       Date:  2009-01-14       Impact factor: 4.176

4.  Polyethylene wear in total hip prostheses: the influence of direction of linear wear on volumetric wear determined from radiographic data.

Authors:  R Kosak; V Antolic; V Pavlovcic; V Kralj-Iglic; I Milosev; G Vidmar; A Iglic
Journal:  Skeletal Radiol       Date:  2003-09-13       Impact factor: 2.199

5.  The Exeter Universal hip in patients 50 years or younger at 10-17 years' followup.

Authors:  Simon C Lewthwaite; Ben Squires; Graham A Gie; Andrew J Timperley; Robin S M Ling
Journal:  Clin Orthop Relat Res       Date:  2008-01-10       Impact factor: 4.176

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.