Literature DB >> 8444910

Exposure of the orthopaedic surgeon to radiation.

R Sanders1, K J Koval, T DiPasquale, G Schmelling, S Stenzler, E Ross.   

Abstract

A prospective study of sixty-five orthopaedic procedures performed with fluoroscopic assistance was undertaken to determine the risk to the primary orthopaedic surgeon with regard to radiation. Radiation was monitored with the use of a universal film badge placed outside the collar of a lead apron, and a gas-sterilized thermoluminescent dosimeter ring worn on each hand. The rings were changed with every operation, but the same film badge was transferred from surgeon to surgeon. The hand dominance of the surgeon, the duration of the operative procedure, the type of operation, and the total time that fluoroscopy had been used were noted. The study was conducted during twenty-one intramedullary nailing procedures (thirteen involving distal locking), forty open reductions with internal fixation (plates and screws), and four external-fixation procedures. All of the badges and rings were submitted for a report regarding radiation exposure. No relationship was found between a ring with a positive reading for exposure to radiation and the duration of the operation. Similarly, there was no correlation between a positive reading and the surgeon's hand dominance. The mean duration of the fluoroscopy was 2.3 minutes for the group for which the rings did not show a positive reading and 4.7 minutes for the group for which the rings did show a positive reading. This was a significant difference (p < 0.0001). There was no positive reading for exposure to radiation from any ring that had been worn during a procedure in which the fluoroscope had been used for less than 1.7 minutes.(ABSTRACT TRUNCATED AT 250 WORDS)

Mesh:

Year:  1993        PMID: 8444910     DOI: 10.2106/00004623-199303000-00003

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  50 in total

1.  McIndoe's scissors--a simple technique to aid distal locking of an intramedullary nail.

Authors:  J Keenan; D Stitson; G J Charnley
Journal:  Ann R Coll Surg Engl       Date:  2000-03       Impact factor: 1.891

2.  [Navigated osteosynthesis of the proximal femur. An experimental study].

Authors:  T Hüfner; M Kfuri; D Kendoff; M Richter; J Geerling; C Krettek
Journal:  Unfallchirurg       Date:  2003-11       Impact factor: 1.000

3.  Three-dimensional computer-assisted navigation for the placement of cannulated hip screws. A pilot study.

Authors:  Marcus Christian Müller; Peter Belei; Peter H Pennekamp; Koroush Kabir; Dieter C Wirtz; Christof Burger; Oliver Weber
Journal:  Int Orthop       Date:  2012-02-23       Impact factor: 3.075

Review 4.  Occupational radiation doses to operators performing fluoroscopically-guided procedures.

Authors:  Kwang Pyo Kim; Donald L Miller; Amy Berrington de Gonzalez; Stephen Balter; Ruth A Kleinerman; Evgenia Ostroumova; Steven L Simon; Martha S Linet
Journal:  Health Phys       Date:  2012-07       Impact factor: 1.316

5.  Occupational radiation exposure from C arm fluoroscopy during common orthopaedic surgical procedures and its prevention.

Authors:  Anupam Mahajan; Sumant Samuel; Atul K Saran; M K Mahajan; M K Mam
Journal:  J Clin Diagn Res       Date:  2015-03-01

6.  [Clinical results with A new retrograde femoral nail with a radiographical-free proximal locking device. A prospective study with 50 fractures].

Authors:  B Friemert; P Keppler; F von Lübken; C Willy; L Claes; H Gerngross; D Wörz
Journal:  Unfallchirurg       Date:  2005-03       Impact factor: 1.000

7.  Distal locking of tibial nails : a new device to reduce radiation exposure.

Authors:  George Anastopoulos; Panagiotis G Ntagiopoulos; Dionisios Chissas; Athanasios Papaeliou; Antonios Asimakopoulos
Journal:  Clin Orthop Relat Res       Date:  2008-01-03       Impact factor: 4.176

8.  [Determining the femoral antetorsion angle with a fluoroscopy-based optoelectronic navigation system: a precision analysis].

Authors:  C Keil; J von Recum; L-P Nolte; A Wentzensen; P A Grützner
Journal:  Unfallchirurg       Date:  2008-02       Impact factor: 1.000

9.  Does the magnetic-guided intramedullary nailing technique shorten operation time and radiation exposure?

Authors:  Muhsin Dursun; Tughan Kalkan; Mahmut Nedim Aytekin; Ismail Celik; Mahmut Uğurlu
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-07-03

10.  [Effectiveness of lead thyroid shield for reducing roentgen ray exposure in trauma surgery interventions of the lower leg].

Authors:  L P Müller; J Suffner; W Mohr; J Degreif; P M Rommens
Journal:  Unfallchirurgie       Date:  1997-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.