Literature DB >> 8366310

A new respiratory rate monitor: development and initial clinical experience.

B Hök1, L Wiklund, S Henneberg.   

Abstract

The need for continuous, noninvasive, and reliable respiratory rate monitoring during recovery from general anesthesia has long been recognized. Alternative principles can be grouped into those detecting the respiratory effort, and those detecting the actual result, i.e. the respiratory gas flow. The second category is of greatest interest for patient monitoring. In this paper, we report the development and initial clinical experience with a new acoustic air-flow sensor. By differential, multipoint detection of the air-flow in the mouth and nose region, the sensor can easily discriminate against different kinds of interference, including motion artefacts. The sensor is nonexpensive, rugged, simple to apply and inherently safe. An instrument with continuous display of respiratory rate, and an audiovisual apnea alarm has been designed and built. The complete system has been tested on patients during recovery after general anesthesia. In 16 patients, the respiratory rate displayed by the instrument has been correlated against that visually observed. A good correlation was obtained. Minor discrepancies can be explained from the fact that visual observation corresponds to the respiratory effort, whereas the sensor detects the actual air flow. In 12 patients, 24 hour simultaneous recordings were made of respiratory rate with the new sensor, with simultaneous recording of the oxygen saturation and the heart rate with a pulse oximeter. It was found that the new sensor reliably recorded respiratory depression and apnea. Such events may in some patients be as frequent as one incident per hour. One case of 'Ondine's curse' provided clear evidence that pulse oximetry has a low sensitivity to respiratory disorders.

Entities:  

Mesh:

Year:  1993        PMID: 8366310     DOI: 10.1007/bf01142280

Source DB:  PubMed          Journal:  Int J Clin Monit Comput        ISSN: 0167-9945


  10 in total

1.  Estimation of respiratory volumes from the photoplethysmographic signal. Part I: Experimental results.

Authors:  A Johansson; P A Oberg
Journal:  Med Biol Eng Comput       Date:  1999-01       Impact factor: 2.602

2.  Evaluation of a new fibre-optical monitor for respiratory rate monitoring.

Authors:  C Larsson; P Staun
Journal:  J Clin Monit Comput       Date:  1999-07       Impact factor: 2.502

Review 3.  Critical review of non-invasive respiratory monitoring in medical care.

Authors:  M Folke; L Cernerud; M Ekström; B Hök
Journal:  Med Biol Eng Comput       Date:  2003-07       Impact factor: 2.602

4.  Monitoring of breathing phases using a bioacoustic method in healthy awake subjects.

Authors:  Hisham Alshaer; Geoffrey R Fernie; T Douglas Bradley
Journal:  J Clin Monit Comput       Date:  2011-09-29       Impact factor: 2.502

5.  A simple inexpensive device for monitoring patient respiration.

Authors:  J Sage; W Gough
Journal:  Med Biol Eng Comput       Date:  1998-03       Impact factor: 2.602

6.  The clinical evaluation of the Respi-check mask: a new oxygen mask incorporating a breathing indicator.

Authors:  A Breakell; C Townsend-Rose
Journal:  Emerg Med J       Date:  2001-09       Impact factor: 2.740

7.  Linshom thermodynamic sensor is a reliable alternative to capnography for monitoring respiratory rate.

Authors:  David Preiss; Benjamin A Drew; James Gosnell; Bhavani S Kodali; James H Philip; Richard D Urman
Journal:  J Clin Monit Comput       Date:  2017-02-22       Impact factor: 2.502

8.  Respiratory monitoring during postoperative analgesia.

Authors:  T Gordh; N Rawal; S Ström; B Hök
Journal:  J Clin Monit       Date:  1995-11

9.  Comparative provocation test of respiratory monitoring methods.

Authors:  Mia Folke; Fredrik Granstedt; Bertil Hök; Håkan Scheer
Journal:  J Clin Monit Comput       Date:  2002-02       Impact factor: 2.502

10.  The PEP transducer: a new way of measuring respiratory rate in the non-intubated patient.

Authors:  D Dodds; J Purdy; C Moulton
Journal:  J Accid Emerg Med       Date:  1999-01
  10 in total