A glucose monitoring system for on line estimation in man of blood glucose concentration using a miniaturized glucose sensor implanted in the subcutaneous tissue and a wearable control unit.

V Poitout1, D Moatti-Sirat, G Reach, Y Zhang, G S Wilson, F Lemonnier, J C Klein.   

Abstract

We have developed a miniaturized glucose sensor which has been shown previously to function adequately when implanted in the subcutaneous tissue of rats and dogs. Following a glucose load, the sensor output increases, making it possible to calculate a sensitivity coefficient to glucose in vivo, and an extrapolated background current in the absence of glucose. These parameters are used for estimating at any time the apparent subcutaneous glucose concentration from the current. In the previous studies, this calibration was performed a posteriori, on the basis of the retrospective analysis of the changes in blood glucose and in the current generated by the sensor. However, for clinical application of the system, an on line estimation of glucose concentration would be necessary. Thus, this study was undertaken in order to assess the possibility of calibrating the sensor in real time, using a novel calibration procedure and a monitoring unit which was specifically designed for this purpose. This electronic device is able to measure, to filter and to store the current. During an oral glucose challenge, when a stable current is reached, it is possible to feed the unit with two different values of blood glucose and their corresponding times. The unit calculates the in vivo parameters, transforms every single value of current into an estimation of the glucose concentration, and then displays this estimation. In this study, 11 sensors were investigated of which two did not respond to glucose. In the other nine trials, the volunteers were asked to record every 30 s what appeared on the display during the secondary decrease in blood glucose.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8359584     DOI: 10.1007/bf00404077

Source DB:  PubMed          Journal:  Diabetologia        ISSN: 0012-186X            Impact factor:   10.122


  19 in total

1.  Calibration in dogs of a subcutaneous miniaturized glucose sensor using a glucose meter for blood glucose determination.

Authors:  V Poitout; D Moatti-Sirat; G Reach
Journal:  Biosens Bioelectron       Date:  1992       Impact factor: 10.618

2.  Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring.

Authors:  D S Bindra; Y Zhang; G S Wilson; R Sternberg; D R Thévenot; D Moatti; G Reach
Journal:  Anal Chem       Date:  1991-09-01       Impact factor: 6.986

3.  Strategies for calibrating a subcutaneous glucose sensor.

Authors:  G Velho; P Froguel; D R Thevenot; G Reach
Journal:  Biomed Biochim Acta       Date:  1989

4.  Evaluating clinical accuracy of systems for self-monitoring of blood glucose.

Authors:  W L Clarke; D Cox; L A Gonder-Frederick; W Carter; S L Pohl
Journal:  Diabetes Care       Date:  1987 Sep-Oct       Impact factor: 19.112

5.  Wearable artificial endocrine pancrease with needle-type glucose sensor.

Authors:  M Shichiri; R Kawamori; Y Yamasaki; N Hakui; H Abe
Journal:  Lancet       Date:  1982-11-20       Impact factor: 79.321

Review 6.  Biosensors: a clinical perspective.

Authors:  J C Pickup
Journal:  Lancet       Date:  1985-10-12       Impact factor: 79.321

7.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

8.  Experience with an implantable glucose sensor as a prerequisite of an artificial beta cell.

Authors:  P Abel; A Müller; U Fischer
Journal:  Biomed Biochim Acta       Date:  1984

9.  Epidemiology of severe hypoglycemia in the diabetes control and complications trial. The DCCT Research Group.

Authors: 
Journal:  Am J Med       Date:  1991-04       Impact factor: 4.965

10.  Subcutaneous glucose monitoring by means of electrochemical sensors: fiction or reality?

Authors:  K Rebrin; U Fischer; H Hahn von Dorsche; T von Woetke; P Abel; E Brunstein
Journal:  J Biomed Eng       Date:  1992-01
View more
  9 in total

1.  Continuous glucose monitoring: real-time algorithms for calibration, filtering, and alarms.

Authors:  B Wayne Bequette
Journal:  J Diabetes Sci Technol       Date:  2010-03-01

2.  Open flow microperfusion: approach to in vivo glucose monitoring.

Authors:  G P Rigby; P Crump; P Vadgama
Journal:  Med Biol Eng Comput       Date:  1995-03       Impact factor: 2.602

Review 3.  Can hypoglycaemia be predicted before its onset?

Authors:  P Lönnroth
Journal:  Diabetologia       Date:  1996-05       Impact factor: 10.122

4.  Hypoglycaemia and glucose sensing.

Authors:  D Baker; M Evans; P Cryer; R Sherwin
Journal:  Diabetologia       Date:  1997-10       Impact factor: 10.122

Review 5.  Biocompatibility issues of implantable drug delivery systems.

Authors:  H Park; K Park
Journal:  Pharm Res       Date:  1996-12       Impact factor: 4.200

6.  Portable system for on-line continuous ex vivo monitoring of subcutaneous tissue glucose using open tissue perfusion.

Authors:  F Skrabal; Z Trajanoski; H Kontscheider; P Kotanko; P Wach
Journal:  Med Biol Eng Comput       Date:  1995-01       Impact factor: 2.602

7.  Comments on subcutaneous glucose monitoring.

Authors:  F Sternberg; C Meyerhoff; F J Mennel; F Bischof; H Mayer; E F Pfeiffer
Journal:  Diabetologia       Date:  1994-05       Impact factor: 10.122

8.  Reduction of acetaminophen interference in glucose sensors by a composite Nafion membrane: demonstration in rats and man.

Authors:  D Moatti-Sirat; V Poitout; V Thomé; M N Gangnerau; Y Zhang; Y Hu; G S Wilson; F Lemonnier; J C Klein; G Reach
Journal:  Diabetologia       Date:  1994-06       Impact factor: 10.122

9.  Glucose monitoring system using nanopellets.

Authors:  C Rajasekaran; Madian Nirmala; K B Jayanthi
Journal:  IET Nanobiotechnol       Date:  2017-02       Impact factor: 1.847

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.