Literature DB >> 20307402

Continuous glucose monitoring: real-time algorithms for calibration, filtering, and alarms.

B Wayne Bequette1.   

Abstract

Algorithms for real-time use in continuous glucose monitors are reviewed, including calibration, filtering of noisy signals, glucose predictions for hypoglycemic and hyperglycemic alarms, compensation for capillary blood glucose to sensor time lags, and fault detection for sensor degradation and dropouts. A tutorial on Kalman filtering for real-time estimation, prediction, and lag compensation is presented and demonstrated via simulation examples. A limited number of fault detection methods for signal degradation and dropout have been published, making that an important area for future work. (c) 2010 Diabetes Technology Society.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20307402      PMCID: PMC2864177          DOI: 10.1177/193229681000400222

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  53 in total

1.  Calibration of a subcutaneous amperometric glucose sensor. Part 1. Effect of measurement uncertainties on the determination of sensor sensitivity and background current.

Authors:  C Choleau; J C Klein; G Reach; B Aussedat; V Demaria-Pesce; G S Wilson; R Gifford; W K Ward
Journal:  Biosens Bioelectron       Date:  2002-08       Impact factor: 10.618

2.  Calibration of a subcutaneous amperometric glucose sensor implanted for 7 days in diabetic patients. Part 2. Superiority of the one-point calibration method.

Authors:  C Choleau; J C Klein; G Reach; B Aussedat; V Demaria-Pesce; G S Wilson; R Gifford; W K Ward
Journal:  Biosens Bioelectron       Date:  2002-08       Impact factor: 10.618

Review 3.  Performance standards for continuous glucose monitors.

Authors:  Paul G Hayter; Manoj Sharma; Lou Dunka; Phil Stout; David A Price; David L Horwitz; Joseph Marhoul; Shabnam Vaez-Zadeh
Journal:  Diabetes Technol Ther       Date:  2005-10       Impact factor: 6.118

Review 4.  Continuous glucose monitoring: roadmap for 21st century diabetes therapy.

Authors:  David C Klonoff
Journal:  Diabetes Care       Date:  2005-05       Impact factor: 19.112

5.  Accuracy of the 5-day FreeStyle Navigator Continuous Glucose Monitoring System: comparison with frequent laboratory reference measurements.

Authors:  Richard L Weinstein; Sherwyn L Schwartz; Ronald L Brazg; Jolyon R Bugler; Thomas A Peyser; Geoffrey V McGarraugh
Journal:  Diabetes Care       Date:  2007-03-02       Impact factor: 19.112

6.  A dual-rate Kalman filter for continuous glucose monitoring.

Authors:  Matthew Kuure-Kinsey; Cesar C Palerm; B Wayne Bequette
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2006

7.  An online self-tunable method to denoise CGM sensor data.

Authors:  Andrea Facchinetti; Giovanni Sparacino; Claudio Cobelli
Journal:  IEEE Trans Biomed Eng       Date:  2009-10-09       Impact factor: 4.538

8.  Evaluating clinical accuracy of systems for self-monitoring of blood glucose.

Authors:  W L Clarke; D Cox; L A Gonder-Frederick; W Carter; S L Pohl
Journal:  Diabetes Care       Date:  1987 Sep-Oct       Impact factor: 19.112

9.  Predicting subcutaneous glucose concentration in humans: data-driven glucose modeling.

Authors:  Adiwinata Gani; Andrei V Gribok; Srinivasan Rajaraman; W Kenneth Ward; Jaques Reifman
Journal:  IEEE Trans Biomed Eng       Date:  2008-09-16       Impact factor: 4.538

10.  Modeling of Calibration Effectiveness and Blood-to-Interstitial Glucose Dynamics as Potential Confounders of the Accuracy of Continuous Glucose Sensors during Hyperinsulinemic Clamp.

Authors:  Christopher King; Stacey M Anderson; Marc Breton; William L Clarke; Boris P Kovatchev
Journal:  J Diabetes Sci Technol       Date:  2007-05
View more
  51 in total

1.  Importance of interleukin-1 and interleukin-1 receptor antagonist in short-term glucose sensor function in vivo.

Authors:  Ulrike Klueh; Zenghe Liu; Ben Feldman; Don Kreutzer
Journal:  J Diabetes Sci Technol       Date:  2010-09-01

2.  Hypoglycemia prevention via pump attenuation and red-yellow-green "traffic" lights using continuous glucose monitoring and insulin pump data.

Authors:  Colleen S Hughes; Stephen D Patek; Marc D Breton; Boris P Kovatchev
Journal:  J Diabetes Sci Technol       Date:  2010-09-01

3.  AP@home: a novel European approach to bring the artificial pancreas home.

Authors:  Lutz Heinemann; Carsten Benesch; J Hans DeVries
Journal:  J Diabetes Sci Technol       Date:  2011-11-01

Review 4.  The challenges of measuring glycemic variability.

Authors:  David Rodbard
Journal:  J Diabetes Sci Technol       Date:  2012-05-01

5.  Use of subcutaneous interstitial fluid glucose to estimate blood glucose: revisiting delay and sensor offset.

Authors:  Kerstin Rebrin; Norman F Sheppard; Garry M Steil
Journal:  J Diabetes Sci Technol       Date:  2010-09-01

6.  Continuous glucose monitoring in subjects with type 1 diabetes: improvement in accuracy by correcting for background current.

Authors:  Joseph El Youssef; Jessica R Castle; Julia M Engle; Ryan G Massoud; W Kenneth Ward
Journal:  Diabetes Technol Ther       Date:  2010-09-30       Impact factor: 6.118

7.  A consensus perceived glycemic variability metric.

Authors:  Cynthia R Marling; Nigel W Struble; Razvan C Bunescu; Jay H Shubrook; Frank L Schwartz
Journal:  J Diabetes Sci Technol       Date:  2013-07-01

8.  Physical activity measured by physical activity monitoring system correlates with glucose trends reconstructed from continuous glucose monitoring.

Authors:  Chiara Zecchin; Andrea Facchinetti; Giovanni Sparacino; Chiara Dalla Man; Chinmay Manohar; James A Levine; Ananda Basu; Yogish C Kudva; Claudio Cobelli
Journal:  Diabetes Technol Ther       Date:  2013-08-14       Impact factor: 6.118

9.  In Vitro Sugar Interference Testing With Amperometric Glucose Oxidase Sensors.

Authors:  Ryan Boehm; John Donovan; Disha Sheth; Andrew Durfor; Jason Roberts; Irada Isayeva
Journal:  J Diabetes Sci Technol       Date:  2018-08-03

10.  Non-Invasive Glucose Monitoring Using Optical Sensor and Machine Learning Techniques for Diabetes Applications.

Authors:  Maryamsadat Shokrekhodaei; David P Cistola; Robert C Roberts; Stella Quinones
Journal:  IEEE Access       Date:  2021-05-11       Impact factor: 3.367

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.