Literature DB >> 8331307

99mTc-sestamibi can improve the inferior attenuation of TL-201 myocardial spect imaging.

S J Wang1, Y T Chen, C L Hwang, M S Lin, C H Kao, S H Yeh.   

Abstract

Tl-201 myocardial scintigraphy (Tl study) tends to be attenuated by soft tissues (such as the diaphragm) due to its low energy emission. 99mTc-sestamibi (2-methoxy isobutyl isonitrile) is a relatively new agent with a higher energy emission and this characteristic accounts for the higher quality of 99mTc-sestamibi images. The purpose of this study is to evaluate the ability of 99mTc-sestamibi in alleviating the inferior attenuation of Tl studies. 99mTc-sestamibi SPECT myocardial scintigraphy was performed on 13 patients with inferior wall perfusion defects as determined by Tl study (but with normal coronary artery as evidenced by cardiac catheterization). All patients underwent Tl SPECT study using a standard procedure. Same-day protocol (rest-stress sequence) was used for 99mTc-sestamibi SPECT imaging. All images were analyzed by two independent observers. The results of our study reveal that 99mTc-sestamibi produced better images. The inferior wall perfusion defects in the T1 study were noted in one case only (1/13) in the 99mTc-sestamibi study. Our study suggests that 99mTc-sestamibi can remarkably reduce the inferior attenuation of Tl study.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8331307     DOI: 10.1007/bf01151432

Source DB:  PubMed          Journal:  Int J Card Imaging        ISSN: 0167-9899


  9 in total

1.  Thallium-201 for medical use. I.

Authors:  E Lebowitz; M W Greene; R Fairchild; P R Bradley-Moore; H L Atkins; A N Ansari; P Richards; E Belgrave
Journal:  J Nucl Med       Date:  1975-02       Impact factor: 10.057

2.  Same day injections of Tc-99m methoxy isobutyl isonitrile (hexamibi) for myocardial tomographic imaging: comparison between rest-stress and stress-rest injection sequences.

Authors:  R Taillefer; A Gagnon; L Laflamme; J Grégoire; J Léveillé; D C Phaneuf
Journal:  Eur J Nucl Med       Date:  1989

3.  The effect of diaphragmatic attenuation on 201Tl images.

Authors:  D G Gordon; M Pfisterer; R Williams; S Walaski; W Ashburn
Journal:  Clin Nucl Med       Date:  1979-04       Impact factor: 7.794

4.  Basal kinetic studies of Tc-99m DMPE as a myocardial imaging agent in the dog.

Authors:  H Nishiyama; E Deutsch; R J Adolph; V J Sodd; K Libson; E L Saenger; M C Gerson; M Gabel; S J Lukes; J L Vanderheyden; D L Fortman; K L Scholz; L W Grossman; C C Williams
Journal:  J Nucl Med       Date:  1982-12       Impact factor: 10.057

5.  Evaluation of 99mTc-dichloro bis (1,2-dimethylphosphino) ethane (99mTc-DMPE) for myocardial scintigraphy in man.

Authors:  R Dudczak; P Angelberger; R Homan; K Kletter; R Schmoliner; H Frischauf
Journal:  Eur J Nucl Med       Date:  1983

6.  Cationic Tc-99m complexes as potential myocardial imaging agents.

Authors:  E Deutsch; K A Glavan; V J Sodd; H Nishiyama; D L Ferguson; S J Lukes
Journal:  J Nucl Med       Date:  1981-10       Impact factor: 10.057

7.  Technetium-99m hexakis 2-methoxyisobutyl isonitrile: human biodistribution, dosimetry, safety, and preliminary comparison to thallium-201 for myocardial perfusion imaging.

Authors:  F J Wackers; D S Berman; J Maddahi; D D Watson; G A Beller; H W Strauss; C A Boucher; M Picard; B L Holman; R Fridrich
Journal:  J Nucl Med       Date:  1989-03       Impact factor: 10.057

8.  Effect of patient positioning on left lateral thallium-201 myocardial images.

Authors:  D E Johnstone; F J Wackers; H J Berger; P B Hoffer; M J Kelley; A Gottschalk; B L Zaret
Journal:  J Nucl Med       Date:  1979-03       Impact factor: 10.057

9.  Heart imaging with cationic complexes of technetium.

Authors:  E Deutsch; W Bushong; K A Glavan; R C Elder; V J Sodd; K L Scholz; D L Fortman; S J Lukes
Journal:  Science       Date:  1981-10-02       Impact factor: 47.728

  9 in total
  4 in total

1.  Gating provides improved accuracy for differentiating artifacts from true lesions in equivocal fixed defects on technetium 99m tetrofosmin perfusion SPECT.

Authors:  J Y Choi; K H Lee; S J Kim; S E Kim; B T Kim; S H Lee; W R Lee
Journal:  J Nucl Cardiol       Date:  1998 Jul-Aug       Impact factor: 5.952

2.  Imaging technology for myocardial perfusion single-photon emission computed tomography 2018 in Japan.

Authors:  Takayuki Shibutani; Koichi Okuda; Hajime Ichikawa; Toyohiro Kato; Kenta Miwa; Hiroyuki Tsushima; Masahisa Onoguchi; Akio Nagaki
Journal:  Jpn J Radiol       Date:  2020-01-09       Impact factor: 2.374

3.  Accuracy of 99mTc-tetrofosmin myocardial tomography in the evaluation of coronary artery disease.

Authors:  S Azzarelli; A R Galassi; R Foti; C Mammana; S Musumeci; G Giuffrida; C Tamburino
Journal:  J Nucl Cardiol       Date:  1999 Mar-Apr       Impact factor: 5.952

4.  Frequency and severity of myocardial perfusion abnormalities using Tc-99m MIBI SPECT in cardiac syndrome X.

Authors:  Mohsen Saghari; Majid Assadi; Mohammad Eftekhari; Mohammad Yaghoubi; Armaghan Fard-Esfahani; Jan-Mohammad Malekzadeh; Babak Fallhi Sichani; Davood Beiki; Abbas Takavar
Journal:  BMC Nucl Med       Date:  2006-02-17
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.