Literature DB >> 8331303

Comparison of planar imaging and single-photon emission computed tomography for the detection and localization of coronary artery disease.

J P Hacot1, M Bojovic, J Delonca, B Meier, A Righetti.   

Abstract

Although single photon emission computed tomography (SPECT) has become widely utilized, the superiority of this technique compared to planar conventional imaging remains controversial. In order to compare these two techniques, we retrospectively analysed the results obtained in 70 patients who performed a thallium-201 exercise scintigraphy with a double acquisition during the same test, and who also underwent coronary and ventricular angiography. Overall, SPECT imaging yielded a higher sensitivity (93% vs 82% for SPECT and planar imaging respectively, p < 0.05), especially in the inferior and anterior regions. SPECT was also more sensitive for the detection of a single-vessel disease (90% vs 74% for SPECT and planar imaging respectively, p < 0.01). The specificity was assessed for both techniques with the help of circumferential computerized analysis, avoiding known causes of false positive scintigrams. We found a high specificity for both SPECT and planar imaging, without any significant difference between the two methods (87% vs 91% for the overall specificity of SPECT and planar imaging respectively, p = NS). Therefore, SPECT imaging analysed with discrimination shows an enhanced reliability over planar imaging for the detection and the localization of coronary artery disease, without increasing the risk of false positive tests.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8331303     DOI: 10.1007/bf01151435

Source DB:  PubMed          Journal:  Int J Card Imaging        ISSN: 0167-9899


  16 in total

1.  How accurate is SPECT thallium scintigraphy?

Authors:  G A Diamond
Journal:  J Am Coll Cardiol       Date:  1990-10       Impact factor: 24.094

2.  SPECT thallium imaging in the diagnosis of myocardial ischemia.

Authors:  A S Iskandrian
Journal:  J Am Coll Cardiol       Date:  1990-10       Impact factor: 24.094

3.  Optimal specificity of thallium-201 SPECT through recognition of imaging artifacts.

Authors:  E G DePuey; E V Garcia
Journal:  J Nucl Med       Date:  1989-04       Impact factor: 10.057

4.  Usefulness of single-photon emission computed tomography of thallium-201 uptake after dipyridamole infusion for detection of coronary artery disease.

Authors:  M A Mendelson; S M Spies; W G Spies; P Abi-Mansour; D J Fintel
Journal:  Am J Cardiol       Date:  1992-05-01       Impact factor: 2.778

5.  Thallium circumferential profiles in the detection of coronary artery disease--assessment by receiver operating characteristic curve analysis.

Authors:  R C Smart; J J Burke; N R Lyons
Journal:  Eur J Nucl Med       Date:  1986

6.  Sensitivity and specificity of tests: can the "silent majority" speak?

Authors:  M E Tavel; N H Enas; J R Woods
Journal:  Am J Cardiol       Date:  1987-11-15       Impact factor: 2.778

7.  Discordance of exercise thallium testing with coronary arteriography in patients with atypical presentations.

Authors:  M W Bungo; O S Leland
Journal:  Chest       Date:  1983-01       Impact factor: 9.410

8.  Improved noninvasive assessment of coronary artery disease by quantitative analysis of regional stress myocardial distribution and washout of thallium-201.

Authors:  J Maddahi; E V Garcia; D S Berman; A Waxman; H J Swan; J Forrester
Journal:  Circulation       Date:  1981-11       Impact factor: 29.690

9.  Improved diagnostic performance of exercise thallium-201 single photon emission computed tomography over planar imaging in the diagnosis of coronary artery disease: a receiver operating characteristic analysis.

Authors:  D J Fintel; J M Links; J A Brinker; T L Frank; M Parker; L C Becker
Journal:  J Am Coll Cardiol       Date:  1989-03-01       Impact factor: 24.094

10.  Space/time quantitation of thallium-201 myocardial scintigraphy.

Authors:  E Garcia; J Maddahi; D Berman; A Waxman
Journal:  J Nucl Med       Date:  1981-04       Impact factor: 10.057

View more
  2 in total

Review 1.  Nuclear cardiology in the UK: do we apply evidence based medicine?

Authors:  S L Rahman; A D Kelion
Journal:  Heart       Date:  2004-08       Impact factor: 5.994

2.  Myocardial perfusion scintigraphy in the UK: insights from the British Nuclear Cardiology Society Survey 2000.

Authors:  A D Kelion; C Anagnostopoulos; M Harbinson; S R Underwood; M Metcalfe
Journal:  Heart       Date:  2005-09       Impact factor: 5.994

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.