Literature DB >> 3732307

Thallium circumferential profiles in the detection of coronary artery disease--assessment by receiver operating characteristic curve analysis.

R C Smart, J J Burke, N R Lyons.   

Abstract

Thallium uptake and redistribution in the myocardium was quantitated using circumferential activity profiles. The profiles were determined from images in the LAO 35, LAO 70 and anterior views, obtained after peak exercise and after 3-4 h redistribution. A retention curve was constructed from these profiles, displaying the redistribution profile as a fraction of the stress profile. Normal values were obtained from 21 normal patients and compared to the images from 68 patients suspected of having coronary artery disease (CAD). Of the latter, 20 had normal/non-significant CAD and 48 had 70% or greater stenosis of one or more vessels on coronary angiography. Several methodological variations were examined: calculation of the profiles using the peak or average counts around the ventricle, uniform or interpolative background subtraction, normalisation of the profiles to their peak or mean counts. Receiver operating characteristic (ROC) curves were generated for profiles calculated using these variations and compared with the ROC curves obtained by visual interpretation of both analogue and computer-enhanced images by two experienced observers. The uniform background subtraction method was found to be better than the interpolative method, and normalisation to the mean of each curve was preferable to normalisation to the peak. ROC curves using profiles calculated using the peak myocardial counts were identical to the ROC curves from profiles using the average counts, but the operating points on the two curves differed. Computer enhancement of the digital images resulted in increased sensitivity for CAD without loss of specificity when compared to the interpretation of the analogue images. The circumferential profiles were found to provide a further increase in sensitivity and were highly reproducible.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3732307     DOI: 10.1007/bf00638788

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  20 in total

1.  Analysis of probability as an aid in the clinical diagnosis of coronary-artery disease.

Authors:  G A Diamond; J S Forrester
Journal:  N Engl J Med       Date:  1979-06-14       Impact factor: 91.245

2.  "Circumferential profiles:" a new method for computer analysis of thallium-201 myocardial perfusion images.

Authors:  R D Burow; M Pond; A W Schafer; L Becker
Journal:  J Nucl Med       Date:  1979-07       Impact factor: 10.057

3.  A new approach to quantitation of exercise thallium-201 scintigraphy before and after an intervention: application to define the impact of coronary angioplasty on regional myocardial perfusion.

Authors:  Y L Lim; R D Okada; D A Chesler; P C Block; C A Boucher; G M Pohost
Journal:  Am Heart J       Date:  1984-10       Impact factor: 4.749

4.  Myocardial imaging with thallium-201: a multicenter study in patients with angina pectoris or acute myocardial infarction.

Authors:  J L Ritchie; B L Zaret; H W Strauss; B Pitt; D S Berman; H R Schelbert; W L Ashburn; H J Berger; G W Hamilton
Journal:  Am J Cardiol       Date:  1978-09       Impact factor: 2.778

5.  Improved computerized quantitation of TI-201 myocardial scintigrams by combining two views.

Authors:  J G Llaurado; J D Horgan; V S Bamrah; C M Kronenwetter; P P Ruetz
Journal:  Clin Nucl Med       Date:  1982-06       Impact factor: 7.794

6.  An intuitive approach to receiver operating characteristic curve analysis.

Authors:  D A Turner
Journal:  J Nucl Med       Date:  1978-02       Impact factor: 10.057

7.  Spatial and temporal quantitation of plane thallium myocardial images.

Authors:  D D Watson; N P Campbell; E K Read; R S Gibson; C D Teates; G A Beller
Journal:  J Nucl Med       Date:  1981-07       Impact factor: 10.057

8.  Observer performance with computer-generated images of 201Tl-Cl myocardial perfusion.

Authors:  S N Wiener; M J Flynn; J Edelstein
Journal:  Radiology       Date:  1980-07       Impact factor: 11.105

9.  Thallium-201 myocardial perfusion imaging at rest and during exercise. Comparative sensitivity to electrocardiography in coronary artery disease.

Authors:  I K Bailey; L S Griffith; J Rouleau; W Strauss; B Pitt
Journal:  Circulation       Date:  1977-01       Impact factor: 29.690

10.  Space/time quantitation of thallium-201 myocardial scintigraphy.

Authors:  E Garcia; J Maddahi; D Berman; A Waxman
Journal:  J Nucl Med       Date:  1981-04       Impact factor: 10.057

View more
  3 in total

1.  Comparison of planar imaging and single-photon emission computed tomography for the detection and localization of coronary artery disease.

Authors:  J P Hacot; M Bojovic; J Delonca; B Meier; A Righetti
Journal:  Int J Card Imaging       Date:  1993-06

2.  Dipyridamole thallium-201 scintigraphy for early risk stratification of patients after uncomplicated myocardial infarction.

Authors:  J Hung; M Moshiri; G N Groom; A A Van der Schaaf; R W Parsons; M E Hands
Journal:  Heart       Date:  1997-10       Impact factor: 5.994

3.  Quantitative evaluation of tomographic 201-thallium myocardial scintigraphy.

Authors:  J Palmer; O Pahlm; T White; K Lyttkens
Journal:  Eur J Nucl Med       Date:  1988
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.