Literature DB >> 7205375

Space/time quantitation of thallium-201 myocardial scintigraphy.

E Garcia, J Maddahi, D Berman, A Waxman.   

Abstract

A comprehensive method is described for quantitation of the spatial distribution of TI-201 in the myocardium and its changes with time. The method, applied here to 51 patients, uses bilinear interpolative background subtraction to compensate for tissue crosstalk, and circumferential profiles to quantitate the relative radionuclide activity in the myocardium as an angular function with origin at the center of the left-ventricular cavity. In addition, washout circumferential profiles are calculated as percent washout from the stress circumferential profiles. Abnormal thallium distribution or washout is identified by automatic computer comparison of each patient's profiles with the corresponding limits of normal profiles, determined from the pooled profiles of 31 normal patients. In these 31, the computer output was normal in all cases. In 20 patients with angiographically documented coronary artery disease, 19 were determined to be abnormal by this method. This new computerized treatment provides accurate objective assessment of the presence of coronary artery disease.

Entities:  

Mesh:

Substances:

Year:  1981        PMID: 7205375

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  31 in total

Review 1.  Advances in quantitative perfusion SPECT imaging.

Authors:  Edward P Ficaro; James R Corbett
Journal:  J Nucl Cardiol       Date:  2004 Jan-Feb       Impact factor: 5.952

Review 2.  The use of computer-assisted diagnosis in cardiac-perfusion nuclear medicine studies: a review.

Authors:  F L Datz; F V Gabor; P E Christian; G T Gullberg; C E Menzel; K A Morton
Journal:  J Digit Imaging       Date:  1992-11       Impact factor: 4.056

Review 3.  Myocardial perfusion scintigraphy: past, present and future.

Authors:  A Notghi; C S Low
Journal:  Br J Radiol       Date:  2011-12       Impact factor: 3.039

4.  Quantitative analysis of myocardial ischaemia on end-diastolic thallium 201 perfusion images.

Authors:  G A Hurwitz; M E Schwab; A C MacDonald; A A Driedger
Journal:  Eur J Nucl Med       Date:  1990

5.  Tl-201 washout rate in remote normal regions in patients with prior myocardial infarction and left ventricular remodeling.

Authors:  Toshihiko Goto; Nobuyuki Ohte; Hiromichi Miyabe; Seiji Mukai; Seiichiro Sakata; Junichiro Hayano; Genjiro Kimura
Journal:  J Nucl Cardiol       Date:  2005 Mar-Apr       Impact factor: 5.952

6.  Myocardial perfusion planar imaging.

Authors:  Peter L Tilkemeier; Frans J Th Wackers
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

7.  Quantitative nuclear cardiology and future directions for SPECT imaging.

Authors:  George A Beller
Journal:  J Nucl Cardiol       Date:  2007-07       Impact factor: 5.952

8.  Exercise gated planar myocardial perfusion imaging using technetium-99m sestamibi for the diagnosis of coronary artery disease: an alternative to exercise tomographic imaging.

Authors:  F Jamar; R Topcuoglu; F Cauwe; P De Coster; V Roelants; C Beckers; W Wijns; J A Melin
Journal:  Eur J Nucl Med       Date:  1995-01

Review 9.  Science, art, and artifacts: how important is quantification for the practicing physician interpreting myocardial perfusion studies?

Authors:  F J Wackers
Journal:  J Nucl Cardiol       Date:  1994 Sep-Oct       Impact factor: 5.952

10.  Tomographic and planar quantitation of perfusion defects on technetium 99m-labeled sestamibi scans: evaluation in patients treated with thrombolytic therapy for acute myocardial infarction.

Authors:  L A Mortelmans; F J Wackers; J L Nuyts; I A Scheys; T Brzostek; C W Schiepers; E E Lesaffre; P L Suetens; A M Verbruggen; F J Van de Werf
Journal:  J Nucl Cardiol       Date:  1995 Mar-Apr       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.