Literature DB >> 16126714

Myocardial perfusion scintigraphy in the UK: insights from the British Nuclear Cardiology Society Survey 2000.

A D Kelion1, C Anagnostopoulos, M Harbinson, S R Underwood, M Metcalfe.   

Abstract

BACKGROUND: The National Institute for Health and Clinical Excellence (NICE) has recently published a very positive technology appraisal of myocardial perfusion scintigraphy (MPS). This has important implications for service provision within the National Health Service, and an accurate knowledge of the current level of MPS activity is necessary.
METHODS: A postal questionnaire was sent to 207 nuclear medicine departments in the UK, requesting information about nuclear cardiology facilities, activity, and practice. Non-responding departments were sent a second questionnaire, followed where necessary by a telephone call.
RESULTS: A response rate of 61% was achieved; 52% of departments performed MPS, and these tended to have more gamma cameras than those which did not (median (25th-75th centile) 2.0, 1.5-2.5 v 1.0, 0.5-1.5; p = 0.02). The median number of studies performed was 256 (144-460). The estimated rate of MPS in the UK for the year 2000 was 1200 per million population. The median (25th-75th centile) waiting time for MPS was 16 (9-24) weeks. Pharmacological stress was used in 77% of studies, and a technetium-99m based radiopharmaceutical in 60% (two day protocol in 75%). Tomographic rather than planar imaging was performed in 88% of studies, of which 22% were ECG gated. A cardiologist was involved in reporting in 35% of studies.
CONCLUSIONS: MPS activity in the UK remains low, and it tends to be provided as a low volume service with unacceptably long waiting times and a lack of involvement by cardiologists. The recent NICE appraisal may provide an impetus for further resourcing and development.

Entities:  

Mesh:

Year:  2005        PMID: 16126714      PMCID: PMC1876391          DOI: 10.1136/hrt.2004.049759

Source DB:  PubMed          Journal:  Heart        ISSN: 1355-6037            Impact factor:   5.994


  13 in total

1.  Quality assurance in myocardial perfusion tomography: a collaborative BNCS/BNMS audit programme. British Nuclear Cardiology Society/British nuclear Medicine Society.

Authors:  E M Prvulovich; P H Jarritt; G C Vivian; S E Clarke; D J Pennell; S R Underwood
Journal:  Nucl Med Commun       Date:  1998-09       Impact factor: 1.690

2.  Investigation and management of stable angina: revised guidelines 1998. Joint Working Party of the British Cardiac Society and Royal College of Physicians of London.

Authors:  D de Bono
Journal:  Heart       Date:  1999-05       Impact factor: 5.994

3.  A survey of nuclear cardiological practice in Great Britain. The British Nuclear Cardiology Group.

Authors:  R Underwood; C Gibson; A Tweddel; J Flint
Journal:  Br Heart J       Date:  1992-03

4.  Nuclear cardiology in the UK: British Nuclear Cardiology Society survey 1994.

Authors:  D J Pennell; E Prvulovich; A Tweddel; J Caplin
Journal:  Nucl Med Commun       Date:  1998-04       Impact factor: 1.690

5.  Comparison of planar imaging and single-photon emission computed tomography for the detection and localization of coronary artery disease.

Authors:  J P Hacot; M Bojovic; J Delonca; B Meier; A Righetti
Journal:  Int J Card Imaging       Date:  1993-06

6.  Incremental prognostic value of post-stress left ventricular ejection fraction and volume by gated myocardial perfusion single photon emission computed tomography.

Authors:  T Sharir; G Germano; P B Kavanagh; S Lai; I Cohen; H C Lewin; J D Friedman; M J Zellweger; D S Berman
Journal:  Circulation       Date:  1999-09-07       Impact factor: 29.690

7.  Improved diagnostic performance of exercise thallium-201 single photon emission computed tomography over planar imaging in the diagnosis of coronary artery disease: a receiver operating characteristic analysis.

Authors:  D J Fintel; J M Links; J A Brinker; T L Frank; M Parker; L C Becker
Journal:  J Am Coll Cardiol       Date:  1989-03-01       Impact factor: 24.094

8.  Using gated technetium-99m-sestamibi SPECT to characterize fixed myocardial defects as infarct or artifact.

Authors:  E G DePuey; A Rozanski
Journal:  J Nucl Med       Date:  1995-06       Impact factor: 10.057

9.  Adenosine combined with dynamic exercise for myocardial perfusion imaging.

Authors:  D J Pennell; S I Mavrogeni; S M Forbat; S P Karwatowski; S R Underwood
Journal:  J Am Coll Cardiol       Date:  1995-05       Impact factor: 24.094

Review 10.  Myocardial perfusion scintigraphy: the evidence.

Authors:  S R Underwood; C Anagnostopoulos; M Cerqueira; P J Ell; E J Flint; M Harbinson; A D Kelion; A Al-Mohammad; E M Prvulovich; L J Shaw; A C Tweddel
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-02       Impact factor: 9.236

View more
  6 in total

1.  Degradation of myocardial perfusion SPECT images caused by contaminants in thallous (201Tl) chloride.

Authors:  Steven G Staelens; Tim C de Wit; Ignace A Lemahieu; Freek J Beekman
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-01-25       Impact factor: 9.236

2.  Appropriateness of referrals for single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI) in a developing community: a comparison between 2005 and 2009 versions of ACCF/ASNC appropriateness criteria.

Authors:  Ali Gholamrezanezhad; Ahmadali Shirafkan; Sahar Mirpour; Mehdi Rayatnavaz; Azita Alborzi; Mehdi Mogharrabi; Sepideh Hassanpour; Mohammadali Ramezani
Journal:  J Nucl Cardiol       Date:  2011-08-05       Impact factor: 5.952

3.  Myocardial perfusion scintigraphy in Europe 2005: a survey of the European Council on Nuclear Cardiology.

Authors:  S Richard Underwood; Susanna Wiener
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-09-20       Impact factor: 9.236

4.  Use of neural networks to improve quality control of interpretations in myocardial perfusion imaging.

Authors:  K Tägil; J Marving; M Lomsky; B Hesse; L Edenbrandt
Journal:  Int J Cardiovasc Imaging       Date:  2008-06-29       Impact factor: 2.357

5.  Sixty-four-slice computed tomography coronary angiography compared with myocardial perfusion scintigraphy for the diagnosis of functionally significant coronary stenoses in patients with a low to intermediate likelihood of coronary artery disease.

Authors:  Edward D Nicol; James Stirrup; Eliana Reyes; Michael Roughton; Simon P G Padley; Michael B Rubens; S Richard Underwood
Journal:  J Nucl Cardiol       Date:  2008-04-16       Impact factor: 5.952

6.  Regadenoson in Europe: first-year experience of regadenoson stress combined with submaximal exercise in patients undergoing myocardial perfusion scintigraphy.

Authors:  M Brinkert; E Reyes; S Walker; K Latus; A Maenhout; R Mizumoto; C Nkomo; K Standbridge; K Wechalekar; S R Underwood
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-11-22       Impact factor: 9.236

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.