An analysis of autopsy findings in 108 patients who died after valve replacement.

H Ishibashi-Ueda1, M Imakita, M Katsuragi, H Fujita, H Hao, C Yutani.   

Abstract

The pathological findings and the causes of death were reviewed in 108 patients who had received 142 heart valve prostheses (52 mechanical and 90 bioprostheses) at the National Cardiovascular Center in Osaka, Japan, from 1977 to 1991. Rheumatic heart disease was the major underlying disease (60.2%), and the age distribution at death ranged from 21 to 80-year-old. Survival duration after the surgery extended from 0 day to 9 years. Thirty-three patients (30.6%) died of perioperative complications such as myocardial haemorrhage and damage, or from heart failure which had been evident prior to the operation, a cause of death which pre-dominated in patients who died within 1 week of surgery (15/17; 88.2%). Thirty-eight patients (35.2%) died of prostheses-related problems such as prosthetic valve failure (cuspal tears and calcifying destruction of the xenograft), thromboembolism, and prosthetic valve endocarditis. Endocarditis was frequent in patients who had survived longer than 1 year (25/33; 75.8%). None of the patients died of prostheses-related problems within 1 week. Non-infectious valve failure was more common in patients with bioprostheses than in those with mechanical valves; thromboembolism showed the opposite association. Prosthetic valve infective endocarditis was nearly equal in frequency in both types of valve.

Entities:  

Mesh:

Year:  1993        PMID: 8322455     DOI: 10.1007/bf01605459

Source DB:  PubMed          Journal:  Virchows Arch A Pathol Anat Histopathol        ISSN: 0174-7398


  14 in total

1.  Structural changes in glutaraldehyde-treated porcine heterografts used as substitute cardiac valves. Transmission and scanning electron microscopic observations in 12 patients.

Authors:  V J Ferrans; T L Spray; M E Billingham; W C Roberts
Journal:  Am J Cardiol       Date:  1978-06       Impact factor: 2.778

2.  Degenerative pathologic findings after long-term implantation of bovine pericardial bioprosthetic heart valves.

Authors:  F Nistal; V García-Martínez; D Fernández; E Artiñano; F Mazorra; I Gallo
Journal:  J Thorac Cardiovasc Surg       Date:  1988-10       Impact factor: 5.209

3.  Primary tissue failure in pericardial heart valves.

Authors:  D J Wheatley; J Fisher; I J Reece; T Spyt; P Breeze
Journal:  J Thorac Cardiovasc Surg       Date:  1987-09       Impact factor: 5.209

4.  Pathology of bioprosthetic cardiac valves.

Authors:  V J Ferrans; Y Tomita; S L Hilbert; M Jones; W C Roberts
Journal:  Hum Pathol       Date:  1987-06       Impact factor: 3.466

5.  Long-term follow-up of the Ionescu-Shiley mitral pericardial xenograft.

Authors:  S Gabbay; U Bortolotti; F Wasserman; N Tindel; S M Factor; R W Frater
Journal:  J Thorac Cardiovasc Surg       Date:  1984-11       Impact factor: 5.209

6.  Causes of failure and pathologic findings in surgically removed Ionescu-Shiley standard bovine pericardial heart valve bioprostheses: emphasis on progressive structural deterioration.

Authors:  F J Schoen; J Fernandez; L Gonzalez-Lavin; A Cernaianu
Journal:  Circulation       Date:  1987-09       Impact factor: 29.690

7.  The risk of thromboembolism and hemorrhage following mitral valve replacement. A comparative analysis between the porcine xenograft valve and Ionescu-Shiley bovine pericardial valve.

Authors:  L Gonzalez-Lavin; A P Tandon; S Chi; T C Blair; P M McFadden; B Lewis; G Daughters; M Ionescu
Journal:  J Thorac Cardiovasc Surg       Date:  1984-03       Impact factor: 5.209

8.  Morphologic findings and causes of failure in 24 explanted Ionescu-Shiley low-profile pericardial heart valves.

Authors:  J Butany; K Vanlerberghe; M D Silver
Journal:  Hum Pathol       Date:  1992-11       Impact factor: 3.466

9.  Anatomic analysis of removed prosthetic heart valves: causes of failure of 33 mechanical valves and 58 bioprostheses, 1980 to 1983.

Authors:  F J Schoen; C E Hobson
Journal:  Hum Pathol       Date:  1985-06       Impact factor: 3.466

10.  Mechanical failure of the Björk-Shiley valve. Incidence, clinical presentation, and management.

Authors:  D Lindblom; V O Björk; B K Semb
Journal:  J Thorac Cardiovasc Surg       Date:  1986-11       Impact factor: 5.209

View more
  2 in total

Review 1.  Acp. Best practice no 155. Pathological investigation of deaths following surgery, anaesthesia, and medical procedures.

Authors:  R D Start; S S Cross
Journal:  J Clin Pathol       Date:  1999-09       Impact factor: 3.411

2.  Prospective study of the value of necropsy examination in early death after cardiac surgery.

Authors:  A H Lee; B T Borek; P J Gallagher; R Saunders; R K Lamb; S A Livesey; V T Tsang; J L Monro
Journal:  Heart       Date:  1997-07       Impact factor: 5.994

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.