Mechanical failure of the Björk-Shiley valve. Incidence, clinical presentation, and management.

D Lindblom, V O Björk, B K Semb.   

Abstract

The experience after implantation of 3,334 Björk-Shiley valves over a 15 year period is described. With a 99.2% follow-up (covering 17,511 patient-years, mean follow-up time 6.3 years) and an autopsy rate of 75% among all fatalities, altogether 19 cases of mechanical failure were documented. There were no mechanical failures among the standard Delrin Björk-Shiley valve (n = 271), the aortic standard Pyrolyte Björk-Shiley (n = 739), or the Monostrut Björk-Shiley valve (n = 377). One of the mitral standard Pyrolyte valves (n = 430) fractured. Among the 1,461 convexo-concave valves, 18 fractured (6/884 with an opening angle of 60 degrees and 12/577 with an opening angle of 70 degrees). The actuarial incidence of mechanical failure at 5 years was 0.6% (with an upper 95% confidence limit of 1.2%) for the 60 degree convexo-concave valve and 2.8% (upper 95% confidence limit of 4.4%) for the 70 degree convexo-concave valve (p less than 0.01). Two groups of valves were especially affected by this complication; the 23 mm aortic 60 degree convexo-concave valve (5 year actuarial incidence 2.2%, upper 95% confidence limit 4.7%) and the 29 to 31 mm mitral 70 degree convexo-concave valve (8.3%, upper 95% confidence limit 14.2%). The hazard function presently indicates a constant (60 degree convexo-concave) or decreasing (70 degree convexo-concave) tendency for mechanical failure. The time interval between the first symptom of mechanical failure and circulatory collapse was significantly (p less than 0.01) shorter after aortic failure than after mitral failure, and no patient with a fractured aortic prosthesis survived long enough to undergo reoperation. The incidence of mechanical failure among patients dying suddenly (but with an autopsy) was 9.6% (95% confidence limits 4.9%-16.6%), and most cases of sudden death were unrelated to the prosthesis. The management of patients with suspected mechanical failure is described. Prophylactic re-replacements are discussed but cannot be generally recommended at present.

Entities:  

Mesh:

Year:  1986        PMID: 3773546

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  12 in total

1.  Outlet strut fracture of Björk-Shiley convexo concave heart valves: the UK cohort study.

Authors:  R Z Omar; L S Morton; D A Halliday; E M Danns; M T Beirne; W J Blot; K M Taylor
Journal:  Heart       Date:  2001-07       Impact factor: 5.994

2.  Management of patients with Björk-Shiley prosthetic valves.

Authors:  D Lindblom
Journal:  Br Heart J       Date:  1992-08

3.  A 4-year experience with the Björk-Shiley Monostrut valve.

Authors:  G Maddern; H S Paterson; D R Craddock; I K Ross; J Stubberfield; S Picozzi; P B Leppard
Journal:  Tex Heart Inst J       Date:  1990

4.  Outlet-strut fracture and disc embolization in 27-mm and smaller Björk-Shiley convexo-concave valves: historical overview and 3 case reports.

Authors:  C G Montero; R Burgos; J E Rodriguez; D Figuera
Journal:  Tex Heart Inst J       Date:  1989

5.  Replacement of a Björk-Shiley Delrin aortic valve still functioning after 25 years.

Authors:  M Ismail Badak; Erdem Ali Ozkisacik; Mehmet Boga; Ugur Gurcun; Berent Discigil
Journal:  Tex Heart Inst J       Date:  2004

6.  Radiologic search for embolized leaflets of prosthetic heart valves: a report of two cases.

Authors:  H Schurawitzki; P C Hajek; J Kramer; F Grabenwöger; W Klepetko; A Moritz
Journal:  Cardiovasc Intervent Radiol       Date:  1989 Jan-Feb       Impact factor: 2.740

7.  An analysis of autopsy findings in 108 patients who died after valve replacement.

Authors:  H Ishibashi-Ueda; M Imakita; M Katsuragi; H Fujita; H Hao; C Yutani
Journal:  Virchows Arch A Pathol Anat Histopathol       Date:  1993

8.  Long-term experience with the Bjork-Shiley Monostrut tilting disc valve.

Authors:  Hyuk Ahn; Kyung Hwan Kim; Dong Jin Kim; Dong Seop Jeong
Journal:  J Korean Med Sci       Date:  2007-12       Impact factor: 2.153

9.  Asymptomatic strut fracture in DeBakey-Surgitool aortic valves: incidence, management, and metallurgic aspects.

Authors:  J Von Der Emde J; U Eberlein; J Breme J
Journal:  Tex Heart Inst J       Date:  1990

10.  Mitral valve replacement with the SORIN valve. Long-term follow-up of 1,161 patients.

Authors:  A Pellegrini; T Colombo; E Quaini; C Russo; E Vitali; F Donatelli
Journal:  Tex Heart Inst J       Date:  1991
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.