Literature DB >> 3626599

Primary tissue failure in pericardial heart valves.

D J Wheatley, J Fisher, I J Reece, T Spyt, P Breeze.   

Abstract

A number of centers have recorded a significant incidence of primary tissue failure with the standard Ionescu-Shiley pericardial valve. In most cases severe regurgitation was caused by leaflet tears adjacent to the edge of the cloth-covered stent. Our early clinical experience (up to 4 years' follow-up) with two new pericardial valves (Ionescu-Shiley low-profile and Hancock pericardial valves) has shown that primary tissue failure also occurs in these new valves. In vitro accelerated fatigue studies on seven of these valves (size 29 mm) showed that in vitro premature leaflet failure was caused by abrasion of the leaflet on the cloth-covering at the edge of the stent. Clinically, endothelialization and host tissue ingrowth on the cloth and the leaflets at the edge of the frame greatly reduced the amount of abrasion and the incidence of tissue failure. In seven of the eight explanted valves studied, leaflet tears occurred at the top of the stent posts where there was less endothelialization and tissue ingrowth, close to the points where sutures pass through the leaflets. It is likely that both abrasion and stress concentration around these sutures contributed to the tissue failures in the clinical valves.

Entities:  

Mesh:

Year:  1987        PMID: 3626599

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  8 in total

Review 1.  A look at recent improvements in the durability of tissue valves.

Authors:  Takahiro Nishida; Ryuji Tominaga
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-01-24

2.  Ionescu-Shiley bovine pericardial bioprostheses. Histologic and ultrastructural studies.

Authors:  S L Hilbert; V J Ferrans; H A McAllister; D A Cooley
Journal:  Am J Pathol       Date:  1992-05       Impact factor: 4.307

3.  Simulated transcatheter aortic valve deformation: A parametric study on the impact of leaflet geometry on valve peak stress.

Authors:  Kewei Li; Wei Sun
Journal:  Int J Numer Method Biomed Eng       Date:  2016-07-26       Impact factor: 2.747

4.  An analysis of autopsy findings in 108 patients who died after valve replacement.

Authors:  H Ishibashi-Ueda; M Imakita; M Katsuragi; H Fujita; H Hao; C Yutani
Journal:  Virchows Arch A Pathol Anat Histopathol       Date:  1993

5.  Early-phase events with the mitroflow pericardial valve.

Authors:  L B McGrath; L Gonzalez-Lavin
Journal:  Tex Heart Inst J       Date:  1988

6.  Characterizing the collagen fiber orientation in pericardial leaflets under mechanical loading conditions.

Authors:  S Hamed Alavi; Victor Ruiz; Tatiana Krasieva; Elliot L Botvinick; Arash Kheradvar
Journal:  Ann Biomed Eng       Date:  2012-11-21       Impact factor: 3.934

7.  Hemodynamics and mechanobiology of aortic valve inflammation and calcification.

Authors:  Kartik Balachandran; Philippe Sucosky; Ajit P Yoganathan
Journal:  Int J Inflam       Date:  2011-07-06

Review 8.  Mechanotransduction in the Cardiovascular System: From Developmental Origins to Homeostasis and Pathology.

Authors:  Gloria Garoffolo; Maurizio Pesce
Journal:  Cells       Date:  2019-12-11       Impact factor: 6.600

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.